{"schemaVersion":3,"id":"CVE-2017-12741","aliases":[],"status":"published","duplicateOf":null,"title":null,"description":"Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.","dates":{"published":"2017-12-26T04:00:00.000Z","modified":"2024-08-05T18:51:06.315Z","reserved":null,"kevAdded":[],"kevDue":[]},"cvss":{"headline":{"score":8.7,"severity":"high","version":"4.0","versionLabel":"v4.0","source":"CVE.org","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","computed":false,"selection":"backend-summary"},"metrics":[{"version":"4.0","versionLabel":"v4.0","source":"CVE.org","score":8.7,"severity":"high","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"CVE.org","score":7.5,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false},{"version":"4.0","versionLabel":"v4.0","source":"NVD","score":8.7,"severity":"high","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"NVD","score":7.5,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false},{"version":"3.0","versionLabel":"v3.0","source":"NVD","score":7.5,"severity":"high","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false},{"version":"2.0","versionLabel":"v2.0","source":"NVD","score":7.8,"severity":"high","vector":"AV:N/AC:L/Au:N/C:N/I:N/A:C","exploitability":null,"impact":null,"computed":false}]},"epss":{"probability":0.03315,"percentile":0.8842,"severity":"low","asOf":"2026-10-19T00:00:00.000Z","change":{"pp":0,"baselineDate":"2026-09-19T00:00:00.000Z","baselineScore":0.03315},"history":[{"date":"2026-09-14T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-15T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-16T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-17T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-18T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.03325,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.03315,"percentile":0.8842}],"last30":[{"date":"2026-09-19T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.03325,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.03315,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.03315,"percentile":0.8842}]},"kev":{"state":"not-listed","entries":[],"listedCount":0,"totalCatalogs":3,"catalogs":[{"source":"cisa","label":"CISA","listed":false,"entry":null},{"source":"enisa","label":"ENISA","listed":false,"entry":null},{"source":"circl","label":"CIRCL","listed":false,"entry":null}]},"ransomware":{"state":"none-recorded","sources":[]},"exploits":[],"exploitCount":0,"weaknesses":[{"id":"CWE-400","name":"Uncontrolled Resource Consumption","description":"The product does not properly control the allocation and maintenance of a limited resource.","type":"weakness","status":"Draft","abstraction":"Class","likelihoodOfExploit":"High","url":"https://cwe.mitre.org/data/definitions/400.html"}],"affected":[{"vendor":"siemens","product":"development/evaluation kits for profinet io: dk standard ethernet controller","name":"Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller","label":"development/evaluation kits for profinet io: dk standard ethernet controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.1.1 Patch 05","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.1.1 Patch 05","eol":null,"hubHref":null},{"vendor":"siemens","product":"development/evaluation kits for profinet io: ek-ertec 200","name":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200","label":"development/evaluation kits for profinet io: ek-ertec 200","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.5","eol":null,"hubHref":null},{"vendor":"siemens","product":"development/evaluation kits for profinet io: ek-ertec 200p","name":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P","label":"development/evaluation kits for profinet io: ek-ertec 200p","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.5","eol":null,"hubHref":null},{"vendor":"siemens","product":"dk_standard_ethernet_controller","name":"dk standard ethernet controller","label":"dk_standard_ethernet_controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/dk_standard_ethernet_controller"},{"vendor":"siemens","product":"ek-ertec_200p_firmware","name":"ek-ertec 200p firmware","label":"ek-ertec_200p_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.5","eol":null,"hubHref":"/vendor/siemens/ek-ertec_200p"},{"vendor":"siemens","product":"ek-ertec_200pn_io_firmware","name":"ek-ertec 200pn io firmware","label":"ek-ertec_200pn_io_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/ek-ertec_200pn_io"},{"vendor":"siemens","product":"simatic_compact_field_unit_firmware","name":"simatic compact field unit firmware","label":"simatic_compact_field_unit_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null},{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions (No fix recorded) | na","eol":null,"hubHref":"/vendor/siemens/simatic_compact_field_unit"},{"vendor":"siemens","product":"simatic_et_200al_firmware","name":"simatic et 200al firmware","label":"simatic_et_200al_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_et_200al"},{"vendor":"siemens","product":"simatic et 200al im 157-1 pn","name":"SIMATIC ET 200AL IM 157-1 PN","label":"simatic et 200al im 157-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V1.0.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V1.0.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200al_im_157-1_pn"},{"vendor":"siemens","product":"simatic_et_200ecopn_firmware","name":"simatic et 200ecopn firmware","label":"simatic_et_200ecopn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_et_200ecopn"},{"vendor":"siemens","product":"simatic_et_200m_firmware","name":"simatic et 200m firmware","label":"simatic_et_200m_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_et_200m"},{"vendor":"siemens","product":"simatic et 200m (incl. siplus variants)","name":"SIMATIC ET 200M (incl. SIPLUS variants)","label":"simatic et 200m (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200m_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_et_200mp_firmware","name":"simatic et 200mp firmware","label":"simatic_et_200mp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_ba_firmware","name":"simatic et 200mp im 155-5 pn ba firmware","label":"simatic_et_200mp_im_155-5_pn_ba_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.0.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.0.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_ba"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_hf_firmware","name":"simatic et 200mp im 155-5 pn hf firmware","label":"simatic_et_200mp_im_155-5_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_hf"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_st_firmware","name":"simatic et 200mp im 155-5 pn st firmware","label":"simatic_et_200mp_im_155-5_pn_st_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_st"},{"vendor":"siemens","product":"simatic_et_200pro_firmware","name":"simatic et 200pro firmware","label":"simatic_et_200pro_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro"},{"vendor":"siemens","product":"simatic et 200pro im 154-3 pn hf","name":"SIMATIC ET 200pro IM 154-3 PN HF","label":"simatic et 200pro im 154-3 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-3_pn_hf"},{"vendor":"siemens","product":"simatic et 200pro im 154-4 pn hf","name":"SIMATIC ET 200pro IM 154-4 PN HF","label":"simatic et 200pro im 154-4 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-4_pn_hf"},{"vendor":"siemens","product":"simatic_et_200s_firmware","name":"simatic et 200s firmware","label":"simatic_et_200s_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_et_200s"},{"vendor":"siemens","product":"simatic_et_200sp_firmware","name":"simatic et 200sp firmware","label":"simatic_et_200sp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_ba_firmware","name":"simatic et 200sp im 155-6 pn ba firmware","label":"simatic_et_200sp_im_155-6_pn_ba_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_ba"},{"vendor":"siemens","product":"simatic et 200sp im 155-6 pn ha (incl. siplus variants)","name":"SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)","label":"simatic et 200sp im 155-6 pn ha (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_ha_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_hf_firmware","name":"simatic et 200sp im 155-6 pn hf firmware","label":"simatic_et_200sp_im_155-6_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_hf"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_hs_firmware","name":"simatic et 200sp im 155-6 pn hs firmware","label":"simatic_et_200sp_im_155-6_pn_hs_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.0.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.0.1","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_hs"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_st_firmware","name":"simatic et 200sp im 155-6 pn st firmware","label":"simatic_et_200sp_im_155-6_pn_st_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_st"},{"vendor":"siemens","product":"simatic et 200sp im 155-6 pn st ba","name":"SIMATIC ET 200SP IM 155-6 PN ST BA","label":"simatic et 200sp im 155-6 pn st ba","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_st_ba"},{"vendor":"siemens","product":"simatic et200ecopn, 16di, dc24v, 8xm12","name":"SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12","label":"simatic et200ecopn, 16di, dc24v, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_16di_dc24v_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 16do dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 16do dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_16do_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 4ao u/i 4xm12","name":"SIMATIC ET200ecoPN, 4AO U/I 4xM12","label":"simatic et200ecopn, 4ao u/i 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_4ao_ui_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8 dio, dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 8 dio, dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8_dio_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8 do, dc24v/2a, 8xm12","name":"SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12","label":"simatic et200ecopn, 8 do, dc24v/2a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8_do_dc24v2a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8ai; 4 u/i; 4 rtd/tc 8xm12","name":"SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12","label":"simatic et200ecopn, 8ai; 4 u/i; 4 rtd/tc 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8ai_4_ui_4_rtdtc_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8ai rtd/tc 8xm12","name":"SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12","label":"simatic et200ecopn, 8ai rtd/tc 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8ai_rtdtc_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8di, dc24v, 4xm12","name":"SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12","label":"simatic et200ecopn, 8di, dc24v, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8di_dc24v_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8di, dc24v, 8xm12","name":"SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12","label":"simatic et200ecopn, 8di, dc24v, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8di_dc24v_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/0,5a, 4xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12","label":"simatic et200ecopn, 8do, dc24v/0,5a, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v05a_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/1,3a, 4xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12","label":"simatic et200ecopn, 8do, dc24v/1,3a, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v13a_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 8do, dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn: io-link master","name":"SIMATIC ET200ecoPN: IO-Link Master","label":"simatic et200ecopn: io-link master","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":null},{"vendor":"siemens","product":"simatic et200s (incl. siplus variants)","name":"SIMATIC ET200S (incl. SIPLUS variants)","label":"simatic et200s (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200s_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_pn\\/pn_coupler_firmware","name":"simatic pn\\/pn coupler firmware","label":"simatic_pn\\/pn_coupler_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_pnpn_coupler"},{"vendor":"siemens","product":"simatic pn/pn coupler (incl. siplus net variants)","name":"SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)","label":"simatic pn/pn coupler (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.2.0","eol":null,"hubHref":"/vendor/siemens/simatic_pnpn_coupler_incl_siplus_net_variants"},{"vendor":"siemens","product":"simatic_s7-1200_firmware","name":"simatic s7-1200 firmware","label":"simatic_s7-1200_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1200"},{"vendor":"siemens","product":"simatic s7-1200 cpu family (incl. siplus variants)","name":"SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","label":"simatic s7-1200 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.2.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.2.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1200_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_s7-1500","name":"simatic s7-1500","label":"simatic_s7-1500","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500"},{"vendor":"siemens","product":"simatic_s7-1500_controller_firmware","name":"simatic s7-1500 controller firmware","label":"simatic_s7-1500_controller_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_controller"},{"vendor":"siemens","product":"simatic s7-1500 cpu family (incl. related et200 cpus and siplus variants)","name":"SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)","label":"simatic s7-1500 cpu family (incl. related et200 cpus and siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_family_incl_related_et200_cpus_and_siplus_variants"},{"vendor":"siemens","product":"simatic_s7-1500_software_controller","name":"simatic s7-1500 software controller","label":"simatic_s7-1500_software_controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_software_controller"},{"vendor":"siemens","product":"simatic_s7-200_firmware","name":"simatic s7-200 firmware","label":"simatic_s7-200_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.03.01","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.03.01","eol":null,"hubHref":"/vendor/siemens/simatic_s7-200"},{"vendor":"siemens","product":"simatic_s7-200_smart_firmware","name":"simatic s7-200 smart firmware","label":"simatic_s7-200_smart_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.03.01","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.03.01","eol":null,"hubHref":"/vendor/siemens/simatic_s7-200_smart"},{"vendor":"siemens","product":"simatic_s7-300_firmware","name":"simatic s7-300 firmware","label":"simatic_s7-300_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300"},{"vendor":"siemens","product":"simatic s7-300 cpu family (incl. related et200 cpus and siplus variants)","name":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","label":"simatic s7-300 cpu family (incl. related et200 cpus and siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.X.16","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.X.16","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_family_incl_related_et200_cpus_and_siplus_variants"},{"vendor":"siemens","product":"simatic s7-400 h v6 and below cpu family (incl. siplus variants)","name":"SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)","label":"simatic s7-400 h v6 and below cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.0.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.0.8","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_h_v6_and_below_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-400 pn/dp v6 and below cpu family (incl. siplus variants)","name":"SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)","label":"simatic s7-400 pn/dp v6 and below cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_pndp_v6_and_below_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-400 pn/dp v7 cpu family (incl. siplus variants)","name":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","label":"simatic s7-400 pn/dp v7 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.2","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_pndp_v7_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_s7-400h_v6_firmware","name":"simatic s7-400h v6 firmware","label":"simatic_s7-400h_v6_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 6.0.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 6.0.8","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400h_v6"},{"vendor":"siemens","product":"simatic_s7-400pn_v6_firmware","name":"simatic s7-400pn v6 firmware","label":"simatic_s7-400pn_v6_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 6.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 6.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400pn_v6"},{"vendor":"siemens","product":"simatic_s7-400pn\\/dp_v7_firmware","name":"simatic s7-400pn\\/dp v7 firmware","label":"simatic_s7-400pn\\/dp_v7_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400pndp_v7"},{"vendor":"siemens","product":"simatic_s7-410_v8_firmware","name":"simatic s7-410 v8 firmware","label":"simatic_s7-410_v8_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_s7-410_v8"},{"vendor":"siemens","product":"simatic s7-410 v8 cpu family (incl. siplus variants)","name":"SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)","label":"simatic s7-410 v8 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V8.2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V8.2.1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-410_v8_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_tdc_cp51m1_firmware","name":"simatic tdc cp51m1 firmware","label":"simatic_tdc_cp51m1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V1.1.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V1.1.8","eol":null,"hubHref":"/vendor/siemens/simatic_tdc_cp51m1"},{"vendor":"siemens","product":"simatic_tdc_cpu555_firmware","name":"simatic tdc cpu555 firmware","label":"simatic_tdc_cpu555_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V1.1.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V1.1.1","eol":null,"hubHref":"/vendor/siemens/simatic_tdc_cpu555"},{"vendor":"siemens","product":"simatic_winac_rtx_2010","name":"simatic winac rtx 2010","label":"simatic_winac_rtx_2010","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2010 SP3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2010 SP3","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_2010"},{"vendor":"siemens","product":"simatic_winac_rtx_\\(f\\)_2010_firmware","name":"simatic winac rtx \\(f\\) 2010 firmware","label":"simatic_winac_rtx_\\(f\\)_2010_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2010 SP3","noFixRecorded":false,"fixedIn":null},{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2010 SP3 | na","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_f_2010"},{"vendor":"siemens","product":"simocode_pro_v_profinet_firmware","name":"simocode pro v profinet firmware","label":"simocode_pro_v_profinet_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simocode_pro_v_profinet"},{"vendor":"siemens","product":"simocode pro v profinet (incl. siplus variants)","name":"SIMOCODE pro V PROFINET (incl. SIPLUS variants)","label":"simocode pro v profinet (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.1.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.1.1","eol":null,"hubHref":"/vendor/siemens/simocode_pro_v_profinet_incl_siplus_variants"},{"vendor":"siemens","product":"simotion_c_firmware","name":"simotion c firmware","label":"simotion_c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V5.1 HF1","noFixRecorded":false,"fixedIn":null},{"text":"≤ 5.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V5.1 HF1 | ≤ 5.1","eol":null,"hubHref":"/vendor/siemens/simotion_c"},{"vendor":"siemens","product":"simotion_d_firmware","name":"simotion d firmware","label":"simotion_d_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V5.1 HF1","noFixRecorded":false,"fixedIn":null},{"text":"≤ 5.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V5.1 HF1 | ≤ 5.1","eol":null,"hubHref":"/vendor/siemens/simotion_d"},{"vendor":"siemens","product":"simotion d4xx v4.4 for sinamics sm150i-2 w. profinet (incl. siplus variants)","name":"SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)","label":"simotion d4xx v4.4 for sinamics sm150i-2 w. profinet (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.4 HF26","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.4 HF26","eol":null,"hubHref":"/vendor/siemens/simotion_d4xx_v44_for_sinamics_sm150i-2_w_profinet_incl_siplus_variants"},{"vendor":"siemens","product":"simotion_p_firmware","name":"simotion p firmware","label":"simotion_p_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≤ 5.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"≤ 5.1","eol":null,"hubHref":"/vendor/siemens/simotion_p"},{"vendor":"siemens","product":"simotion p v4.4 and v4.5","name":"SIMOTION P V4.4 and V4.5","label":"simotion p v4.4 and v4.5","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.5 HF5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.5 HF5","eol":null,"hubHref":"/vendor/siemens/simotion_p_v44_and_v45"},{"vendor":"siemens","product":"simotion p v5","name":"SIMOTION P V5","label":"simotion p v5","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V5.1 HF1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V5.1 HF1","eol":null,"hubHref":"/vendor/siemens/simotion_p_v5"},{"vendor":"siemens","product":"sinamics_dcm_firmware","name":"sinamics dcm firmware","label":"sinamics_dcm_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_dcm"},{"vendor":"siemens","product":"sinamics dcm w. pn","name":"SINAMICS DCM w. PN","label":"sinamics dcm w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.4 SP1 HF6","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.4 SP1 HF6","eol":null,"hubHref":"/vendor/siemens/sinamics_dcm_w_pn"},{"vendor":"siemens","product":"sinamics_dcp_firmware","name":"sinamics dcp firmware","label":"sinamics_dcp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_dcp"},{"vendor":"siemens","product":"sinamics dcp w. pn","name":"SINAMICS DCP w. PN","label":"sinamics dcp w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.2 HF2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.2 HF2","eol":null,"hubHref":"/vendor/siemens/sinamics_dcp_w_pn"},{"vendor":"siemens","product":"sinamics g110m w. pn","name":"SINAMICS G110M w. PN","label":"sinamics g110m w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP9 HF1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP9 HF1","eol":null,"hubHref":"/vendor/siemens/sinamics_g110m_w_pn"},{"vendor":"siemens","product":"sinamics_g110m\\/g120pn_firmware","name":"sinamics g110m\\/g120pn firmware","label":"sinamics_g110m\\/g120pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≤ 4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"≤ 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_g110mg120pn"},{"vendor":"siemens","product":"sinamics g120(c/p/d) w. pn (incl. siplus variants)","name":"SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)","label":"sinamics g120(c/p/d) w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP9 HF1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP9 HF1","eol":null,"hubHref":"/vendor/siemens/sinamics_g120cpd_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics_g130_firmware","name":"sinamics g130 firmware","label":"sinamics_g130_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_g130"},{"vendor":"siemens","product":"sinamics g130 v4.7 w. pn","name":"SINAMICS G130 V4.7 w. PN","label":"sinamics g130 v4.7 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF29","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF29","eol":null,"hubHref":"/vendor/siemens/sinamics_g130_v47_w_pn"},{"vendor":"siemens","product":"sinamics g130 v4.8 w. pn","name":"SINAMICS G130 V4.8 w. PN","label":"sinamics g130 v4.8 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 HF4","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 HF4","eol":null,"hubHref":"/vendor/siemens/sinamics_g130_v48_w_pn"},{"vendor":"siemens","product":"sinamics_g150_firmware","name":"sinamics g150 firmware","label":"sinamics_g150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_g150"},{"vendor":"siemens","product":"sinamics g150 v4.7 w. pn","name":"SINAMICS G150 V4.7 w. PN","label":"sinamics g150 v4.7 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF29","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF29","eol":null,"hubHref":"/vendor/siemens/sinamics_g150_v47_w_pn"},{"vendor":"siemens","product":"sinamics g150 v4.8 w. pn","name":"SINAMICS G150 V4.8 w. PN","label":"sinamics g150 v4.8 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 HF4","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 HF4","eol":null,"hubHref":"/vendor/siemens/sinamics_g150_v48_w_pn"},{"vendor":"siemens","product":"sinamics gh150 v4.7 w. profinet","name":"SINAMICS GH150 V4.7 w. PROFINET","label":"sinamics gh150 v4.7 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP5 HF7","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP5 HF7","eol":null,"hubHref":"/vendor/siemens/sinamics_gh150_v47_w_profinet"},{"vendor":"siemens","product":"sinamics gl150 v4.7 w. profinet","name":"SINAMICS GL150 V4.7 w. PROFINET","label":"sinamics gl150 v4.7 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP2","eol":null,"hubHref":"/vendor/siemens/sinamics_gl150_v47_w_profinet"},{"vendor":"siemens","product":"sinamics gm150 v4.7 w. profinet","name":"SINAMICS GM150 V4.7 w. PROFINET","label":"sinamics gm150 v4.7 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF31","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF31","eol":null,"hubHref":"/vendor/siemens/sinamics_gm150_v47_w_profinet"},{"vendor":"siemens","product":"sinamics s110 w. pn","name":"SINAMICS S110 w. PN","label":"sinamics s110 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.4 SP3 HF6","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.4 SP3 HF6","eol":null,"hubHref":"/vendor/siemens/sinamics_s110_w_pn"},{"vendor":"siemens","product":"sinamics_s110pn_firmware","name":"sinamics s110pn firmware","label":"sinamics_s110pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_s110pn"},{"vendor":"siemens","product":"sinamics_s120_firmware","name":"sinamics s120 firmware","label":"sinamics_s120_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_s120"},{"vendor":"siemens","product":"sinamics s120 prior to v4.7 w. pn (incl. siplus variants)","name":"SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)","label":"sinamics s120 prior to v4.7 w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_prior_to_v47_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics s120 v4.7 sp1 w. pn (incl. siplus variants)","name":"SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)","label":"sinamics s120 v4.7 sp1 w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_v47_sp1_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics s120 v4.7 w. pn (incl. siplus variants)","name":"SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)","label":"sinamics s120 v4.7 w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF29","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF29","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_v47_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics s120 v4.8 w. pn (incl. siplus variants)","name":"SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)","label":"sinamics s120 v4.8 w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 HF5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 HF5","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_v48_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics_s150_v4.7_firmware","name":"sinamics s150 v4.7 firmware","label":"sinamics_s150_v4.7_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_s150_v47"},{"vendor":"siemens","product":"sinamics s150 v4.7 w. pn","name":"SINAMICS S150 V4.7 w. PN","label":"sinamics s150 v4.7 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF29","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF29","eol":null,"hubHref":"/vendor/siemens/sinamics_s150_v47_w_pn"},{"vendor":"siemens","product":"sinamics_s150_v4.8_firmware","name":"sinamics s150 v4.8 firmware","label":"sinamics_s150_v4.8_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_s150_v48"},{"vendor":"siemens","product":"sinamics s150 v4.8 w. pn","name":"SINAMICS S150 V4.8 w. PN","label":"sinamics s150 v4.8 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 HF4","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 HF4","eol":null,"hubHref":"/vendor/siemens/sinamics_s150_v48_w_pn"},{"vendor":"siemens","product":"sinamics sl150 v4.7.0 w. profinet","name":"SINAMICS SL150 V4.7.0 w. PROFINET","label":"sinamics sl150 v4.7.0 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF30","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF30","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150_v470_w_profinet"},{"vendor":"siemens","product":"sinamics sl150 v4.7.4 w. profinet","name":"SINAMICS SL150 V4.7.4 w. PROFINET","label":"sinamics sl150 v4.7.4 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP2","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150_v474_w_profinet"},{"vendor":"siemens","product":"sinamics sl150 v4.7.5 w. profinet","name":"SINAMICS SL150 V4.7.5 w. PROFINET","label":"sinamics sl150 v4.7.5 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP2","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150_v475_w_profinet"},{"vendor":"siemens","product":"sinamics sm120 v4.7 w. profinet","name":"SINAMICS SM120 V4.7 w. PROFINET","label":"sinamics sm120 v4.7 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP2","eol":null,"hubHref":"/vendor/siemens/sinamics_sm120_v47_w_profinet"},{"vendor":"siemens","product":"sinamics v90 w. pn","name":"SINAMICS V90 w. PN","label":"sinamics v90 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.02","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.02","eol":null,"hubHref":"/vendor/siemens/sinamics_v90_w_pn"},{"vendor":"siemens","product":"sinamics_v90pn_firmware","name":"sinamics v90pn firmware","label":"sinamics_v90pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sinamics_v90pn"},{"vendor":"siemens","product":"sinumerik_840d_sl","name":"sinumerik 840d sl","label":"sinumerik_840d_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP3","noFixRecorded":false,"fixedIn":null},{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP3 | na","eol":null,"hubHref":"/vendor/siemens/sinumerik_840d_sl"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn hf","name":"SIPLUS ET 200MP IM 155-5 PN HF","label":"siplus et 200mp im 155-5 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_hf"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn hf t1 rail","name":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","label":"siplus et 200mp im 155-5 pn hf t1 rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_hf_t1_rail"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn st","name":"SIPLUS ET 200MP IM 155-5 PN ST","label":"siplus et 200mp im 155-5 pn st","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_st"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn st tx rail","name":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","label":"siplus et 200mp im 155-5 pn st tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_st_tx_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf","name":"SIPLUS ET 200SP IM 155-6 PN HF","label":"siplus et 200sp im 155-6 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf t1 rail","name":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","label":"siplus et 200sp im 155-6 pn hf t1 rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf_t1_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st","name":"SIPLUS ET 200SP IM 155-6 PN ST","label":"siplus et 200sp im 155-6 pn st","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st ba","name":"SIPLUS ET 200SP IM 155-6 PN ST BA","label":"siplus et 200sp im 155-6 pn st ba","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_ba"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st ba tx rail","name":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","label":"siplus et 200sp im 155-6 pn st ba tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_ba_tx_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st tx rail","name":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","label":"siplus et 200sp im 155-6 pn st tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_tx_rail"},{"vendor":"siemens","product":"sirius_soft_starter_3rw44_pn_firmware","name":"sirius soft starter 3rw44 pn firmware","label":"sirius_soft_starter_3rw44_pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sirius_soft_starter_3rw44_pn"},{"vendor":"siemens","product":"sirius_soft_starter_3rw44pn_firmware","name":"sirius soft starter 3rw44pn firmware","label":"sirius_soft_starter_3rw44pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/sirius_soft_starter_3rw44pn"}],"affectedCount":119,"eol":{"hasEol":false,"count":0},"references":[{"url":"https://www.securityfocus.com/bid/101964","label":"www.securityfocus.com/bid/101964","hostname":"www.securityfocus.com","tags":["VDB Entry","X Refsource BID"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf","hostname":"cert-portal.siemens.com","tags":["X Refsource CONFIRM"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf","hostname":"cert-portal.siemens.com","tags":["X Refsource CONFIRM"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf","hostname":"cert-portal.siemens.com","tags":["X Refsource CONFIRM"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-346262.html","label":"cert-portal.siemens.com/productcert/html/ssa-346262.html","hostname":"cert-portal.siemens.com","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-546832.html","label":"cert-portal.siemens.com/productcert/html/ssa-546832.html","hostname":"cert-portal.siemens.com","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-141614.html","label":"cert-portal.siemens.com/productcert/html/ssa-141614.html","hostname":"cert-portal.siemens.com","tags":[]}],"lineage":{"upstream":[],"downstream":[],"duplicates":[],"related":[]},"timeline":[{"kind":"published","date":"2017-12-26T04:00:00.000Z","label":"Published","detail":"Vulnerability first disclosed.","source":null},{"kind":"modified","date":"2024-08-05T18:51:06.315Z","label":"Last modified","detail":"Vulnerability information updated.","source":null}],"risk":{"score":35,"level":"medium","profile":"Default","thresholds":{"critical":75,"high":50,"medium":25,"low":10}},"meta":{"dataAsOf":"2026-10-19T20:50:48.042Z","stale":false,"partial":false}}