{"schemaVersion":3,"id":"CVE-2017-2680","aliases":[],"status":"published","duplicateOf":null,"title":null,"description":"Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.","dates":{"published":"2017-05-11T01:00:00.000Z","modified":"2024-09-10T09:33:18.492Z","reserved":null,"kevAdded":[],"kevDue":[]},"cvss":{"headline":{"score":7.1,"severity":"high","version":"4.0","versionLabel":"v4.0","source":"CVE.org","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","computed":false,"selection":"backend-summary"},"metrics":[{"version":"4.0","versionLabel":"v4.0","source":"CVE.org","score":7.1,"severity":"high","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"CVE.org","score":6.5,"severity":"medium","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false},{"version":"4.0","versionLabel":"v4.0","source":"NVD","score":7.1,"severity":"high","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"NVD","score":6.5,"severity":"medium","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false},{"version":"2.0","versionLabel":"v2.0","source":"NVD","score":6.1,"severity":"medium","vector":"AV:A/AC:L/Au:N/C:N/I:N/A:C","exploitability":null,"impact":null,"computed":false}]},"epss":{"probability":0.01149,"percentile":0.66325,"severity":"low","asOf":"2026-10-18T00:00:00.000Z","change":{"pp":0,"baselineDate":"2026-09-18T00:00:00.000Z","baselineScore":0.01149},"history":[{"date":"2026-09-14T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-15T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-16T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-17T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-18T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01149,"percentile":0.66325}],"last30":[{"date":"2026-09-18T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01149,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01149,"percentile":0.66325}]},"kev":{"state":"not-listed","entries":[],"listedCount":0,"totalCatalogs":3,"catalogs":[{"source":"cisa","label":"CISA","listed":false,"entry":null},{"source":"enisa","label":"ENISA","listed":false,"entry":null},{"source":"circl","label":"CIRCL","listed":false,"entry":null}]},"ransomware":{"state":"none-recorded","sources":[]},"exploits":[],"exploitCount":0,"weaknesses":[{"id":"CWE-400","name":"Uncontrolled Resource Consumption","description":"The product does not properly control the allocation and maintenance of a limited resource.","type":"weakness","status":"Draft","abstraction":"Class","likelihoodOfExploit":"High","url":"https://cwe.mitre.org/data/definitions/400.html"}],"affected":[{"vendor":"siemens","product":"development/evaluation kits for profinet io: dk standard ethernet controller","name":"Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller","label":"development/evaluation kits for profinet io: dk standard ethernet controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.1.1 Patch04","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.1.1 Patch04","eol":null,"hubHref":null},{"vendor":"siemens","product":"development/evaluation kits for profinet io: ek-ertec 200","name":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200","label":"development/evaluation kits for profinet io: ek-ertec 200","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.2.1 Patch03","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.2.1 Patch03","eol":null,"hubHref":null},{"vendor":"siemens","product":"development/evaluation kits for profinet io: ek-ertec 200p","name":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P","label":"development/evaluation kits for profinet io: ek-ertec 200p","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.4.0 Patch01","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.4.0 Patch01","eol":null,"hubHref":null},{"vendor":"siemens","product":"dk_standard_ethernet_controller","name":"dk standard ethernet controller","label":"dk_standard_ethernet_controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.1.1","noFixRecorded":false,"fixedIn":null},{"text":"4.1.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.1.1 | 4.1.1","eol":null,"hubHref":"/vendor/siemens/dk_standard_ethernet_controller"},{"vendor":"siemens","product":"ek-ertec_200_pn_io_firmware","name":"ek-ertec 200 pn io firmware","label":"ek-ertec_200_pn_io_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.2.1","noFixRecorded":false,"fixedIn":null},{"text":"4.2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.2.1 | 4.2.1","eol":null,"hubHref":"/vendor/siemens/ek-ertec_200_pn_io"},{"vendor":"siemens","product":"ek-ertec_200p_pn_io_firmware","name":"ek-ertec 200p pn io firmware","label":"ek-ertec_200p_pn_io_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.4.0","noFixRecorded":false,"fixedIn":null},{"text":"4.4.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.4.0 | 4.4.0","eol":null,"hubHref":"/vendor/siemens/ek-ertec_200p_pn_io"},{"vendor":"siemens","product":"extension_unit_12_profinet_firmware","name":"extension unit 12 profinet firmware","label":"extension_unit_12_profinet_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V01.01.01","noFixRecorded":false,"fixedIn":null},{"text":"< 01.01.01","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V01.01.01 | < 01.01.01","eol":null,"hubHref":"/vendor/siemens/extension_unit_12_profinet"},{"vendor":"siemens","product":"extension_unit_15_profinet_firmware","name":"extension unit 15 profinet firmware","label":"extension_unit_15_profinet_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V01.01.01","noFixRecorded":false,"fixedIn":null},{"text":"< 01.01.01","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V01.01.01 | < 01.01.01","eol":null,"hubHref":"/vendor/siemens/extension_unit_15_profinet"},{"vendor":"siemens","product":"extension_unit_19_profinet_firmware","name":"extension unit 19 profinet firmware","label":"extension_unit_19_profinet_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V01.01.01","noFixRecorded":false,"fixedIn":null},{"text":"< 01.01.01","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V01.01.01 | < 01.01.01","eol":null,"hubHref":"/vendor/siemens/extension_unit_19_profinet"},{"vendor":"siemens","product":"extension_unit_22_profinet_firmware","name":"extension unit 22 profinet firmware","label":"extension_unit_22_profinet_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V01.01.01","noFixRecorded":false,"fixedIn":null},{"text":"< 01.01.01","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V01.01.01 | < 01.01.01","eol":null,"hubHref":"/vendor/siemens/extension_unit_22_profinet"},{"vendor":"siemens","product":"ie\\/as-i_link_pn_io_firmware","name":"ie\\/as-i link pn io firmware","label":"ie\\/as-i_link_pn_io_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/ieas-i_link_pn_io"},{"vendor":"siemens","product":"ie\\/pb-link_firmware","name":"ie\\/pb-link firmware","label":"ie\\/pb-link_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.0","eol":null,"hubHref":"/vendor/siemens/iepb-link"},{"vendor":"siemens","product":"ie/pb-link (incl. siplus net variants)","name":"IE/PB-Link (incl. SIPLUS NET variants)","label":"ie/pb-link (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.0","eol":null,"hubHref":"/vendor/siemens/iepb-link_incl_siplus_net_variants"},{"vendor":"siemens","product":"pn\\/pn_coupler_firmware","name":"pn\\/pn coupler firmware","label":"pn\\/pn_coupler_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.0","eol":null,"hubHref":"/vendor/siemens/pnpn_coupler"},{"vendor":"siemens","product":"scalance_m-800_firmware","name":"scalance m-800 firmware","label":"scalance_m-800_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.03","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.03","eol":null,"hubHref":"/vendor/siemens/scalance_m-800"},{"vendor":"siemens","product":"scalance m-800 family (incl. s615, mum-800 and rm1224)","name":"SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)","label":"scalance m-800 family (incl. s615, mum-800 and rm1224)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.03","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.03","eol":null,"hubHref":"/vendor/siemens/scalance_m-800_family_incl_s615_mum-800_and_rm1224"},{"vendor":"siemens","product":"scalance_s615_firmware","name":"scalance s615 firmware","label":"scalance_s615_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.03","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.03","eol":null,"hubHref":"/vendor/siemens/scalance_s615"},{"vendor":"siemens","product":"scalance w-700 ieee 802.11n family","name":"SCALANCE W-700 IEEE 802.11n family","label":"scalance w-700 ieee 802.11n family","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V6.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V6.1","eol":null,"hubHref":"/vendor/siemens/scalance_w-700_ieee_80211n_family"},{"vendor":"siemens","product":"scalance_w700_firmware","name":"scalance w700 firmware","label":"scalance_w700_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 6.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 6.1","eol":null,"hubHref":"/vendor/siemens/scalance_w700"},{"vendor":"siemens","product":"scalance x-200 family (incl. siplus net variants)","name":"SCALANCE X-200 family (incl. SIPLUS NET variants)","label":"scalance x-200 family (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V5.2.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V5.2.2","eol":null,"hubHref":"/vendor/siemens/scalance_x-200_family_incl_siplus_net_variants"},{"vendor":"siemens","product":"scalance x-200irt family (incl. siplus net variants)","name":"SCALANCE X-200IRT family (incl. SIPLUS NET variants)","label":"scalance x-200irt family (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V5.4.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V5.4.0","eol":null,"hubHref":"/vendor/siemens/scalance_x-200irt_family_incl_siplus_net_variants"},{"vendor":"siemens","product":"scalance x-300 family (incl. x408 and siplus net variants)","name":"SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)","label":"scalance x-300 family (incl. x408 and siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.1.0","eol":null,"hubHref":"/vendor/siemens/scalance_x-300_family_incl_x408_and_siplus_net_variants"},{"vendor":"siemens","product":"scalance_x200_firmware","name":"scalance x200 firmware","label":"scalance_x200_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.2","eol":null,"hubHref":"/vendor/siemens/scalance_x200"},{"vendor":"siemens","product":"scalance_x200_irt_firmware","name":"scalance x200 irt firmware","label":"scalance_x200_irt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.4.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.4.0","eol":null,"hubHref":"/vendor/siemens/scalance_x200_irt"},{"vendor":"siemens","product":"scalance_x300_firmware","name":"scalance x300 firmware","label":"scalance_x300_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.1.0","eol":null,"hubHref":"/vendor/siemens/scalance_x300"},{"vendor":"siemens","product":"scalance_x408_firmware","name":"scalance x408 firmware","label":"scalance_x408_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.1.0","eol":null,"hubHref":"/vendor/siemens/scalance_x408"},{"vendor":"siemens","product":"scalance x408 family","name":"SCALANCE X408 family","label":"scalance x408 family","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.1.0","eol":null,"hubHref":"/vendor/siemens/scalance_x408_family"},{"vendor":"siemens","product":"scalance_x414_firmware","name":"scalance x414 firmware","label":"scalance_x414_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.10.2","noFixRecorded":false,"fixedIn":null},{"text":"< 3.10.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.10.2 | < 3.10.2","eol":null,"hubHref":"/vendor/siemens/scalance_x414"},{"vendor":"siemens","product":"scalance xm-400 family","name":"SCALANCE XM-400 family","label":"scalance xm-400 family","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V6.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V6.1","eol":null,"hubHref":"/vendor/siemens/scalance_xm-400_family"},{"vendor":"siemens","product":"scalance_xm400_firmware","name":"scalance xm400 firmware","label":"scalance_xm400_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 6.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 6.1","eol":null,"hubHref":"/vendor/siemens/scalance_xm400"},{"vendor":"siemens","product":"scalance xr-500 family","name":"SCALANCE XR-500 family","label":"scalance xr-500 family","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V6.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V6.1","eol":null,"hubHref":"/vendor/siemens/scalance_xr-500_family"},{"vendor":"siemens","product":"scalance_xr500_firmware","name":"scalance xr500 firmware","label":"scalance_xr500_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 6.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 6.1","eol":null,"hubHref":"/vendor/siemens/scalance_xr500"},{"vendor":"siemens","product":"simatic_cm_1542-1_firmware","name":"simatic cm 1542-1 firmware","label":"simatic_cm_1542-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.0","noFixRecorded":false,"fixedIn":null},{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.0 | < 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_cm_1542-1"},{"vendor":"siemens","product":"simatic_cm_1542sp-1_firmware","name":"simatic cm 1542sp-1 firmware","label":"simatic_cm_1542sp-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.0.15","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.0.15","eol":null,"hubHref":"/vendor/siemens/simatic_cm_1542sp-1"},{"vendor":"siemens","product":"simatic_cp_1242-7_gprs_firmware","name":"simatic cp 1242-7 gprs firmware","label":"simatic_cp_1242-7_gprs_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1242-7_gprs"},{"vendor":"siemens","product":"simatic cp 1242-7 v2 (incl. siplus variants)","name":"SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)","label":"simatic cp 1242-7 v2 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1242-7_v2_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_cp_1243-1_firmware","name":"simatic cp 1243-1 firmware","label":"simatic_cp_1243-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-1"},{"vendor":"siemens","product":"simatic cp 1243-1 dnp3 (incl. siplus variants)","name":"SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)","label":"simatic cp 1243-1 dnp3 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-1_dnp3_incl_siplus_variants"},{"vendor":"siemens","product":"simatic cp 1243-1 iec (incl. siplus variants)","name":"SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)","label":"simatic cp 1243-1 iec (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-1_iec_incl_siplus_variants"},{"vendor":"siemens","product":"simatic cp 1243-1 (incl. siplus variants)","name":"SIMATIC CP 1243-1 (incl. SIPLUS variants)","label":"simatic cp 1243-1 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-1_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_cp_1243-1_irc_firmware","name":"simatic cp 1243-1 irc firmware","label":"simatic_cp_1243-1_irc_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-1_irc"},{"vendor":"siemens","product":"simatic_cp_1243-7_lte_us_firmware","name":"simatic cp 1243-7 lte us firmware","label":"simatic_cp_1243-7_lte_us_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-7_lte_us"},{"vendor":"siemens","product":"simatic_cp_1243-7_lte\\/us_firmware","name":"simatic cp 1243-7 lte\\/us firmware","label":"simatic_cp_1243-7_lte\\/us_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-7_lteus"},{"vendor":"siemens","product":"simatic_cp_1243-8_firmware","name":"simatic cp 1243-8 firmware","label":"simatic_cp_1243-8_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-8"},{"vendor":"siemens","product":"simatic_cp_1243-8_irc_firmware","name":"simatic cp 1243-8 irc firmware","label":"simatic_cp_1243-8_irc_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.1.82","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.1.82","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1243-8_irc"},{"vendor":"siemens","product":"simatic_cp_1542sp-1_firmware","name":"simatic cp 1542sp-1 firmware","label":"simatic_cp_1542sp-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.0.15","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.0.15","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1542sp-1"},{"vendor":"siemens","product":"simatic_cp_1542sp-1_irc_firmware","name":"simatic cp 1542sp-1 irc firmware","label":"simatic_cp_1542sp-1_irc_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.0.15","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.0.15","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1542sp-1_irc"},{"vendor":"siemens","product":"simatic cp 1542sp-1 irc (incl. siplus variants)","name":"SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)","label":"simatic cp 1542sp-1 irc (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.0.15","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.0.15","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1542sp-1_irc_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_cp_1543-1_firmware","name":"simatic cp 1543-1 firmware","label":"simatic_cp_1543-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.1","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1543-1"},{"vendor":"siemens","product":"simatic cp 1543-1 (incl. siplus variants)","name":"SIMATIC CP 1543-1 (incl. SIPLUS variants)","label":"simatic cp 1543-1 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.1","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1543-1_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_cp_1543sp-1_firmware","name":"simatic cp 1543sp-1 firmware","label":"simatic_cp_1543sp-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.0.15","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.0.15","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1543sp-1"},{"vendor":"siemens","product":"simatic cp 1543sp-1 (incl. siplus variants)","name":"SIMATIC CP 1543SP-1 (incl. SIPLUS variants)","label":"simatic cp 1543sp-1 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.0.15","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.0.15","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1543sp-1_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_cp_1604_firmware","name":"simatic cp 1604 firmware","label":"simatic_cp_1604_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.7","noFixRecorded":false,"fixedIn":null},{"text":"< 2.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.7 | < 2.7","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1604"},{"vendor":"siemens","product":"simatic_cp_1616_firmware","name":"simatic cp 1616 firmware","label":"simatic_cp_1616_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.7","noFixRecorded":false,"fixedIn":null},{"text":"< 2.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.7 | < 2.7","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1616"},{"vendor":"siemens","product":"simatic_cp_1626_firmware","name":"simatic cp 1626 firmware","label":"simatic_cp_1626_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.1","noFixRecorded":false,"fixedIn":null},{"text":"< 1.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.1 | < 1.1","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1626"},{"vendor":"siemens","product":"simatic cp 343-1 advanced (incl. siplus variants)","name":"SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)","label":"simatic cp 343-1 advanced (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_cp_343-1_advanced_incl_siplus_variants"},{"vendor":"siemens","product":"simatic cp 343-1 (incl. siplus variants)","name":"SIMATIC CP 343-1 (incl. SIPLUS variants)","label":"simatic cp 343-1 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.1.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.1.3","eol":null,"hubHref":"/vendor/siemens/simatic_cp_343-1_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_cp_343-1_lean_firmware","name":"simatic cp 343-1 lean firmware","label":"simatic_cp_343-1_lean_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.1.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.1.3","eol":null,"hubHref":"/vendor/siemens/simatic_cp_343-1_lean"},{"vendor":"siemens","product":"simatic cp 343-1 lean (incl. siplus variants)","name":"SIMATIC CP 343-1 Lean (incl. SIPLUS variants)","label":"simatic cp 343-1 lean (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.1.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.1.3","eol":null,"hubHref":"/vendor/siemens/simatic_cp_343-1_lean_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_cp_343-1_std_firmware","name":"simatic cp 343-1 std firmware","label":"simatic_cp_343-1_std_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.1.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.1.3","eol":null,"hubHref":"/vendor/siemens/simatic_cp_343-1_std"},{"vendor":"siemens","product":"simatic_cp_443-1_adv_firmware","name":"simatic cp 443-1 adv firmware","label":"simatic_cp_443-1_adv_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_cp_443-1_adv"},{"vendor":"siemens","product":"simatic cp 443-1 advanced (incl. siplus variants)","name":"SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)","label":"simatic cp 443-1 advanced (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_cp_443-1_advanced_incl_siplus_variants"},{"vendor":"siemens","product":"simatic cp 443-1 (incl. siplus variants)","name":"SIMATIC CP 443-1 (incl. SIPLUS variants)","label":"simatic cp 443-1 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_cp_443-1_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_cp_443-1_opc_ua_firmware","name":"simatic cp 443-1 opc ua firmware","label":"simatic_cp_443-1_opc_ua_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_cp_443-1_opc_ua"},{"vendor":"siemens","product":"simatic_cp_443-1_std_firmware","name":"simatic cp 443-1 std firmware","label":"simatic_cp_443-1_std_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_cp_443-1_std"},{"vendor":"siemens","product":"simatic_dk-1604_pn_io_firmware","name":"simatic dk-1604 pn io firmware","label":"simatic_dk-1604_pn_io_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.7","eol":null,"hubHref":"/vendor/siemens/simatic_dk-1604_pn_io"},{"vendor":"siemens","product":"simatic_dk-1616_pn_io_firmware","name":"simatic dk-1616 pn io firmware","label":"simatic_dk-1616_pn_io_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.7","eol":null,"hubHref":"/vendor/siemens/simatic_dk-1616_pn_io"},{"vendor":"siemens","product":"simatic_dk-16xx_pn_io_firmware","name":"simatic dk-16xx pn io firmware","label":"simatic_dk-16xx_pn_io_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.7","eol":null,"hubHref":"/vendor/siemens/simatic_dk-16xx_pn_io"},{"vendor":"siemens","product":"simatic_et_200al_firmware","name":"simatic et 200al firmware","label":"simatic_et_200al_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.0.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.0.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200al"},{"vendor":"siemens","product":"simatic et 200al im 157-1 pn","name":"SIMATIC ET 200AL IM 157-1 PN","label":"simatic et 200al im 157-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V1.0.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V1.0.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200al_im_157-1_pn"},{"vendor":"siemens","product":"simatic et 200m (incl. siplus variants)","name":"SIMATIC ET 200M (incl. SIPLUS variants)","label":"simatic et 200m (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200m_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_et_200mp_firmware","name":"simatic et 200mp firmware","label":"simatic_et_200mp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.0.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.0.1","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_ba_firmware","name":"simatic et 200mp im 155-5 pn ba firmware","label":"simatic_et_200mp_im_155-5_pn_ba_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.0.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.0.1","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_ba"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_hf_firmware","name":"simatic et 200mp im 155-5 pn hf firmware","label":"simatic_et_200mp_im_155-5_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_hf"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_st_firmware","name":"simatic et 200mp im 155-5 pn st firmware","label":"simatic_et_200mp_im_155-5_pn_st_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_st"},{"vendor":"siemens","product":"simatic et 200pro im 154-3 pn hf","name":"SIMATIC ET 200pro IM 154-3 PN HF","label":"simatic et 200pro im 154-3 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-3_pn_hf"},{"vendor":"siemens","product":"simatic et 200pro im 154-4 pn hf","name":"SIMATIC ET 200pro IM 154-4 PN HF","label":"simatic et 200pro im 154-4 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-4_pn_hf"},{"vendor":"siemens","product":"simatic_et_200sp_firmware","name":"simatic et 200sp firmware","label":"simatic_et_200sp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_ba_firmware","name":"simatic et 200sp im 155-6 pn ba firmware","label":"simatic_et_200sp_im_155-6_pn_ba_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_ba"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_hf_firmware","name":"simatic et 200sp im 155-6 pn hf firmware","label":"simatic_et_200sp_im_155-6_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_hf"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_hs_firmware","name":"simatic et 200sp im 155-6 pn hs firmware","label":"simatic_et_200sp_im_155-6_pn_hs_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.0.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.0.1","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_hs"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_st_firmware","name":"simatic et 200sp im 155-6 pn st firmware","label":"simatic_et_200sp_im_155-6_pn_st_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_st"},{"vendor":"siemens","product":"simatic et 200sp im 155-6 pn st ba","name":"SIMATIC ET 200SP IM 155-6 PN ST BA","label":"simatic et 200sp im 155-6 pn st ba","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_st_ba"},{"vendor":"siemens","product":"simatic et200ecopn, 16di, dc24v, 8xm12","name":"SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12","label":"simatic et200ecopn, 16di, dc24v, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_16di_dc24v_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 16do dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 16do dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_16do_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 4ao u/i 4xm12","name":"SIMATIC ET200ecoPN, 4AO U/I 4xM12","label":"simatic et200ecopn, 4ao u/i 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_4ao_ui_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8 dio, dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 8 dio, dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8_dio_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8 do, dc24v/2a, 8xm12","name":"SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12","label":"simatic et200ecopn, 8 do, dc24v/2a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8_do_dc24v2a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8ai; 4 u/i; 4 rtd/tc 8xm12","name":"SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12","label":"simatic et200ecopn, 8ai; 4 u/i; 4 rtd/tc 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8ai_4_ui_4_rtdtc_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8ai rtd/tc 8xm12","name":"SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12","label":"simatic et200ecopn, 8ai rtd/tc 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8ai_rtdtc_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8di, dc24v, 4xm12","name":"SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12","label":"simatic et200ecopn, 8di, dc24v, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8di_dc24v_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8di, dc24v, 8xm12","name":"SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12","label":"simatic et200ecopn, 8di, dc24v, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8di_dc24v_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/0,5a, 4xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12","label":"simatic et200ecopn, 8do, dc24v/0,5a, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v05a_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/1,3a, 4xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12","label":"simatic et200ecopn, 8do, dc24v/1,3a, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v13a_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 8do, dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn: io-link master","name":"SIMATIC ET200ecoPN: IO-Link Master","label":"simatic et200ecopn: io-link master","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":null},{"vendor":"siemens","product":"simatic et200s (incl. siplus variants)","name":"SIMATIC ET200S (incl. SIPLUS variants)","label":"simatic et200s (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200s_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_hmi_comfort_panels_firmware","name":"simatic hmi comfort panels firmware","label":"simatic_hmi_comfort_panels_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 15.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 15.1","eol":null,"hubHref":"/vendor/siemens/simatic_hmi_comfort_panels"},{"vendor":"siemens","product":"simatic hmi comfort panels, hmi multi panels, hmi mobile panels (incl. siplus variants)","name":"SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)","label":"simatic hmi comfort panels, hmi multi panels, hmi mobile panels (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V15.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V15.1","eol":null,"hubHref":"/vendor/siemens/simatic_hmi_comfort_panels_hmi_multi_panels_hmi_mobile_panels_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_hmi_mobile_panels","name":"simatic hmi mobile panels","label":"simatic_hmi_mobile_panels","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 15.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 15.1","eol":null,"hubHref":"/vendor/siemens/simatic_hmi_mobile_panels"},{"vendor":"siemens","product":"simatic_hmi_multi_panels","name":"simatic hmi multi panels","label":"simatic_hmi_multi_panels","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 15.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 15.1","eol":null,"hubHref":"/vendor/siemens/simatic_hmi_multi_panels"},{"vendor":"siemens","product":"simatic_mv420_sr-b_firmware","name":"simatic mv420 sr-b firmware","label":"simatic_mv420_sr-b_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V7.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_mv420_sr-b"},{"vendor":"siemens","product":"simatic_mv420_sr-b_body_firmware","name":"simatic mv420 sr-b body firmware","label":"simatic_mv420_sr-b_body_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V7.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_mv420_sr-b_body"},{"vendor":"siemens","product":"simatic_mv420_sr-p_firmware","name":"simatic mv420 sr-p firmware","label":"simatic_mv420_sr-p_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V7.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_mv420_sr-p"},{"vendor":"siemens","product":"simatic_mv420_sr-p_body_firmware","name":"simatic mv420 sr-p body firmware","label":"simatic_mv420_sr-p_body_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V7.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_mv420_sr-p_body"},{"vendor":"siemens","product":"simatic_mv440_hr_firmware","name":"simatic mv440 hr firmware","label":"simatic_mv440_hr_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V7.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_mv440_hr"},{"vendor":"siemens","product":"simatic_mv440_sr_firmware","name":"simatic mv440 sr firmware","label":"simatic_mv440_sr_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V7.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_mv440_sr"},{"vendor":"siemens","product":"simatic_mv440_ur_firmware","name":"simatic mv440 ur firmware","label":"simatic_mv440_ur_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V7.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_mv440_ur"},{"vendor":"siemens","product":"simatic pn/pn coupler (incl. siplus net variants)","name":"SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)","label":"simatic pn/pn coupler (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.0","eol":null,"hubHref":"/vendor/siemens/simatic_pnpn_coupler_incl_siplus_net_variants"},{"vendor":"siemens","product":"simatic_rf650r_firmware","name":"simatic rf650r firmware","label":"simatic_rf650r_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.0","noFixRecorded":false,"fixedIn":null},{"text":"< 3.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.0 | < 3.0","eol":null,"hubHref":"/vendor/siemens/simatic_rf650r"},{"vendor":"siemens","product":"simatic_rf680r_firmware","name":"simatic rf680r firmware","label":"simatic_rf680r_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.0","noFixRecorded":false,"fixedIn":null},{"text":"< 3.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.0 | < 3.0","eol":null,"hubHref":"/vendor/siemens/simatic_rf680r"},{"vendor":"siemens","product":"simatic_rf685r_firmware","name":"simatic rf685r firmware","label":"simatic_rf685r_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.0","noFixRecorded":false,"fixedIn":null},{"text":"< 3.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.0 | < 3.0","eol":null,"hubHref":"/vendor/siemens/simatic_rf685r"},{"vendor":"siemens","product":"simatic_s7-1200_firmware","name":"simatic s7-1200 firmware","label":"simatic_s7-1200_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.2.1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1200"},{"vendor":"siemens","product":"simatic s7-1200 cpu family (incl. siplus variants)","name":"SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","label":"simatic s7-1200 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.2.1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1200_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_s7-1500","name":"simatic s7-1500","label":"simatic_s7-1500","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500"},{"vendor":"siemens","product":"simatic s7-1500 cpu family (incl. related et200 cpus and siplus variants)","name":"SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)","label":"simatic s7-1500 cpu family (incl. related et200 cpus and siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_family_incl_related_et200_cpus_and_siplus_variants"},{"vendor":"siemens","product":"simatic_s7-1500_software_controller","name":"simatic s7-1500 software controller","label":"simatic_s7-1500_software_controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.1","noFixRecorded":false,"fixedIn":null},{"text":"< 2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.1 | < 2.1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_software_controller"},{"vendor":"siemens","product":"simatic_s7-200_smart_firmware","name":"simatic s7-200 smart firmware","label":"simatic_s7-200_smart_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.3","noFixRecorded":false,"fixedIn":null},{"text":"< 2.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.3 | < 2.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-200_smart"},{"vendor":"siemens","product":"simatic_s7-300_firmware","name":"simatic s7-300 firmware","label":"simatic_s7-300_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"na","noFixRecorded":false,"fixedIn":null}],"versionsText":"na","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300"},{"vendor":"siemens","product":"simatic s7-300 cpu family (incl. related et200 cpus and siplus variants)","name":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","label":"simatic s7-300 cpu family (incl. related et200 cpus and siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.X.14","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.X.14","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_family_incl_related_et200_cpus_and_siplus_variants"},{"vendor":"siemens","product":"simatic_s7-400_firmware","name":"simatic s7-400 firmware","label":"simatic_s7-400_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 6.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 6.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400"},{"vendor":"siemens","product":"simatic s7-400 h v6 cpu family (incl. siplus variants)","name":"SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)","label":"simatic s7-400 h v6 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.0.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.0.7","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_h_v6_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-400 pn/dp v6 cpu family (incl. siplus variants)","name":"SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)","label":"simatic s7-400 pn/dp v6 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.0.6","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_pndp_v6_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-400 pn/dp v7 cpu family (incl. siplus variants)","name":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","label":"simatic s7-400 pn/dp v7 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.2","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_pndp_v7_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-410 cpu family (incl. siplus variants)","name":"SIMATIC S7-410 CPU family (incl. SIPLUS variants)","label":"simatic s7-410 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V8.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V8.2","eol":null,"hubHref":"/vendor/siemens/simatic_s7-410_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_tdc_cp51m1_firmware","name":"simatic tdc cp51m1 firmware","label":"simatic_tdc_cp51m1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V1.1.8","noFixRecorded":false,"fixedIn":null},{"text":"< 1.1.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V1.1.8 | < 1.1.8","eol":null,"hubHref":"/vendor/siemens/simatic_tdc_cp51m1"},{"vendor":"siemens","product":"simatic_tdc_cpu555_firmware","name":"simatic tdc cpu555 firmware","label":"simatic_tdc_cpu555_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V1.1.1","noFixRecorded":false,"fixedIn":null},{"text":"< 1.1.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V1.1.1 | < 1.1.1","eol":null,"hubHref":"/vendor/siemens/simatic_tdc_cpu555"},{"vendor":"siemens","product":"simatic_teleservice_adapter_ie_advanced_firmware","name":"simatic teleservice adapter ie advanced firmware","label":"simatic_teleservice_adapter_ie_advanced_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_teleservice_adapter_ie_advanced"},{"vendor":"siemens","product":"simatic_teleservice_adapter_ie_basic_firmware","name":"simatic teleservice adapter ie basic firmware","label":"simatic_teleservice_adapter_ie_basic_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_teleservice_adapter_ie_basic"},{"vendor":"siemens","product":"simatic_teleservice_adapter_ie_standard_firmware","name":"simatic teleservice adapter ie standard firmware","label":"simatic_teleservice_adapter_ie_standard_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_teleservice_adapter_ie_standard"},{"vendor":"siemens","product":"simatic_winac_rtx_firmware","name":"simatic winac rtx firmware","label":"simatic_winac_rtx_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2010","noFixRecorded":false,"fixedIn":null},{"text":"2010","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2010 | 2010","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx"},{"vendor":"siemens","product":"simatic_winac_rtx_2010","name":"simatic winac rtx 2010","label":"simatic_winac_rtx_2010","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2010 SP3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2010 SP3","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_2010"},{"vendor":"siemens","product":"simatic_winac_rtx_\\(f\\)_2010_firmware","name":"simatic winac rtx \\(f\\) 2010 firmware","label":"simatic_winac_rtx_\\(f\\)_2010_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2010 SP3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2010 SP3","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_f_2010"},{"vendor":"siemens","product":"simocode_pro_v_profinet_firmware","name":"simocode pro v profinet firmware","label":"simocode_pro_v_profinet_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0.0","eol":null,"hubHref":"/vendor/siemens/simocode_pro_v_profinet"},{"vendor":"siemens","product":"simocode pro v profinet (incl. siplus variants)","name":"SIMOCODE pro V PROFINET (incl. SIPLUS variants)","label":"simocode pro v profinet (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.0.0","eol":null,"hubHref":"/vendor/siemens/simocode_pro_v_profinet_incl_siplus_variants"},{"vendor":"siemens","product":"simotion_firmware","name":"simotion firmware","label":"simotion_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.5 HF1","noFixRecorded":false,"fixedIn":null},{"text":"< 4.5","noFixRecorded":false,"fixedIn":null},{"text":"4.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.5 HF1 | < 4.5 | 4.5","eol":null,"hubHref":"/vendor/siemens/simotion"},{"vendor":"siemens","product":"simotion d4xx v4.4 for sinamics sm150i-2 w. profinet (incl. siplus variants)","name":"SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)","label":"simotion d4xx v4.4 for sinamics sm150i-2 w. profinet (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.4 HF26","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.4 HF26","eol":null,"hubHref":"/vendor/siemens/simotion_d4xx_v44_for_sinamics_sm150i-2_w_profinet_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics__s110_pn_firmware","name":"sinamics  s110 pn firmware","label":"sinamics__s110_pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.4","noFixRecorded":false,"fixedIn":null},{"text":"4.4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.4 | 4.4","eol":null,"hubHref":"/vendor/siemens/sinamics__s110_pn"},{"vendor":"siemens","product":"sinamics_dcm_firmware","name":"sinamics dcm firmware","label":"sinamics_dcm_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.4","noFixRecorded":false,"fixedIn":null},{"text":"1.4","noFixRecorded":false,"fixedIn":null},{"text":"1.4:sp1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.4 | 1.4 | 1.4:sp1","eol":null,"hubHref":"/vendor/siemens/sinamics_dcm"},{"vendor":"siemens","product":"sinamics dcm w. pn","name":"SINAMICS DCM w. PN","label":"sinamics dcm w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.4 SP1 HF5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.4 SP1 HF5","eol":null,"hubHref":"/vendor/siemens/sinamics_dcm_w_pn"},{"vendor":"siemens","product":"sinamics_dcp_firmware","name":"sinamics dcp firmware","label":"sinamics_dcp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.2","noFixRecorded":false,"fixedIn":null},{"text":"1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.2 | 1.2","eol":null,"hubHref":"/vendor/siemens/sinamics_dcp"},{"vendor":"siemens","product":"sinamics dcp w. pn","name":"SINAMICS DCP w. PN","label":"sinamics dcp w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.2 HF1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.2 HF1","eol":null,"hubHref":"/vendor/siemens/sinamics_dcp_w_pn"},{"vendor":"siemens","product":"sinamics_g110m_firmware","name":"sinamics g110m firmware","label":"sinamics_g110m_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_g110m"},{"vendor":"siemens","product":"sinamics g110m w. pn","name":"SINAMICS G110M w. PN","label":"sinamics g110m w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP6 HF3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP6 HF3","eol":null,"hubHref":"/vendor/siemens/sinamics_g110m_w_pn"},{"vendor":"siemens","product":"sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware","name":"sinamics g120\\(c\\/p\\/d\\) w. pn firmware","label":"sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_g120cpd_w_pn"},{"vendor":"siemens","product":"sinamics g120(c/p/d) w. pn (incl. siplus variants)","name":"SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)","label":"sinamics g120(c/p/d) w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP6 HF3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP6 HF3","eol":null,"hubHref":"/vendor/siemens/sinamics_g120cpd_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics_g130_firmware","name":"sinamics g130 firmware","label":"sinamics_g130_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_g130"},{"vendor":"siemens","product":"sinamics g130 v4.7 w. pn","name":"SINAMICS G130 V4.7 w. PN","label":"sinamics g130 v4.7 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF27","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF27","eol":null,"hubHref":"/vendor/siemens/sinamics_g130_v47_w_pn"},{"vendor":"siemens","product":"sinamics g130 v4.8 w. pn","name":"SINAMICS G130 V4.8 w. PN","label":"sinamics g130 v4.8 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 HF4","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 HF4","eol":null,"hubHref":"/vendor/siemens/sinamics_g130_v48_w_pn"},{"vendor":"siemens","product":"sinamics_g150_firmware","name":"sinamics g150 firmware","label":"sinamics_g150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_g150"},{"vendor":"siemens","product":"sinamics g150 v4.7 w. pn","name":"SINAMICS G150 V4.7 w. PN","label":"sinamics g150 v4.7 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"V4.7: All versions < V4.7 HF27","noFixRecorded":false,"fixedIn":null}],"versionsText":"V4.7: All versions < V4.7 HF27","eol":null,"hubHref":"/vendor/siemens/sinamics_g150_v47_w_pn"},{"vendor":"siemens","product":"sinamics g150 v4.8 w. pn","name":"SINAMICS G150 V4.8 w. PN","label":"sinamics g150 v4.8 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 HF4","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 HF4","eol":null,"hubHref":"/vendor/siemens/sinamics_g150_v48_w_pn"},{"vendor":"siemens","product":"sinamics_gh150_firmware","name":"sinamics gh150 firmware","label":"sinamics_gh150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_gh150"},{"vendor":"siemens","product":"sinamics gh150 v4.7 w. profinet","name":"SINAMICS GH150 V4.7 w. PROFINET","label":"sinamics gh150 v4.7 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP5 HF7","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP5 HF7","eol":null,"hubHref":"/vendor/siemens/sinamics_gh150_v47_w_profinet"},{"vendor":"siemens","product":"sinamics_gl150_firmware","name":"sinamics gl150 firmware","label":"sinamics_gl150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.8","noFixRecorded":false,"fixedIn":null},{"text":"4.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8 | 4.8","eol":null,"hubHref":"/vendor/siemens/sinamics_gl150"},{"vendor":"siemens","product":"sinamics gl150 v4.7 w. profinet","name":"SINAMICS GL150 V4.7 w. PROFINET","label":"sinamics gl150 v4.7 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP2","eol":null,"hubHref":"/vendor/siemens/sinamics_gl150_v47_w_profinet"},{"vendor":"siemens","product":"sinamics_gm150_firmware","name":"sinamics gm150 firmware","label":"sinamics_gm150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_gm150"},{"vendor":"siemens","product":"sinamics gm150 v4.7 w. profinet","name":"SINAMICS GM150 V4.7 w. PROFINET","label":"sinamics gm150 v4.7 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF31","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF31","eol":null,"hubHref":"/vendor/siemens/sinamics_gm150_v47_w_profinet"},{"vendor":"siemens","product":"sinamics s110 w. pn","name":"SINAMICS S110 w. PN","label":"sinamics s110 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.4 SP3 HF5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.4 SP3 HF5","eol":null,"hubHref":"/vendor/siemens/sinamics_s110_w_pn"},{"vendor":"siemens","product":"sinamics_s120_firmware","name":"sinamics s120 firmware","label":"sinamics_s120_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_s120"},{"vendor":"siemens","product":"sinamics s120 prior to v4.7 w. pn (incl. siplus variants)","name":"SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)","label":"sinamics s120 prior to v4.7 w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_prior_to_v47_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics s120 v4.7 sp1 w. pn (incl. siplus variants)","name":"SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)","label":"sinamics s120 v4.7 sp1 w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_v47_sp1_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics s120 v4.7 w. pn (incl. siplus variants)","name":"SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)","label":"sinamics s120 v4.7 w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF27","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF27","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_v47_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics s120 v4.8 w. pn (incl. siplus variants)","name":"SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)","label":"sinamics s120 v4.8 w. pn (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 HF4","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 HF4","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_v48_w_pn_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics_s150_firmware","name":"sinamics s150 firmware","label":"sinamics_s150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_s150"},{"vendor":"siemens","product":"sinamics s150 v4.7 w. pn","name":"SINAMICS S150 V4.7 w. PN","label":"sinamics s150 v4.7 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF27","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF27","eol":null,"hubHref":"/vendor/siemens/sinamics_s150_v47_w_pn"},{"vendor":"siemens","product":"sinamics s150 v4.8 w. pn","name":"SINAMICS S150 V4.8 w. PN","label":"sinamics s150 v4.8 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 HF4","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 HF4","eol":null,"hubHref":"/vendor/siemens/sinamics_s150_v48_w_pn"},{"vendor":"siemens","product":"sinamics_sl150_firmware","name":"sinamics sl150 firmware","label":"sinamics_sl150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.8","noFixRecorded":false,"fixedIn":null},{"text":"4.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8 | 4.8","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150"},{"vendor":"siemens","product":"sinamics sl150 v4.7.0 w. profinet","name":"SINAMICS SL150 V4.7.0 w. PROFINET","label":"sinamics sl150 v4.7.0 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF30","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF30","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150_v470_w_profinet"},{"vendor":"siemens","product":"sinamics sl150 v4.7.4 w. profinet","name":"SINAMICS SL150 V4.7.4 w. PROFINET","label":"sinamics sl150 v4.7.4 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP2","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150_v474_w_profinet"},{"vendor":"siemens","product":"sinamics sl150 v4.7.5 w. profinet","name":"SINAMICS SL150 V4.7.5 w. PROFINET","label":"sinamics sl150 v4.7.5 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP2","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150_v475_w_profinet"},{"vendor":"siemens","product":"sinamics_sm120_firmware","name":"sinamics sm120 firmware","label":"sinamics_sm120_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.8","noFixRecorded":false,"fixedIn":null},{"text":"4.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8 | 4.8","eol":null,"hubHref":"/vendor/siemens/sinamics_sm120"},{"vendor":"siemens","product":"sinamics sm120 v4.7 w. profinet","name":"SINAMICS SM120 V4.7 w. PROFINET","label":"sinamics sm120 v4.7 w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP2","eol":null,"hubHref":"/vendor/siemens/sinamics_sm120_v47_w_profinet"},{"vendor":"siemens","product":"sinamics_v90_pn_firmware","name":"sinamics v90 pn firmware","label":"sinamics_v90_pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.01","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.01","eol":null,"hubHref":"/vendor/siemens/sinamics_v90_pn"},{"vendor":"siemens","product":"sinamics v90 w. pn","name":"SINAMICS V90 w. PN","label":"sinamics v90 w. pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.01","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.01","eol":null,"hubHref":"/vendor/siemens/sinamics_v90_w_pn"},{"vendor":"siemens","product":"sinumerik_828d_firmware","name":"sinumerik 828d firmware","label":"sinumerik_828d_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.5","noFixRecorded":false,"fixedIn":null},{"text":"4.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.5 | 4.5","eol":null,"hubHref":"/vendor/siemens/sinumerik_828d"},{"vendor":"siemens","product":"sinumerik 828d v4.5 and prior","name":"SINUMERIK 828D V4.5 and prior","label":"sinumerik 828d v4.5 and prior","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.5 SP6 HF2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.5 SP6 HF2","eol":null,"hubHref":"/vendor/siemens/sinumerik_828d_v45_and_prior"},{"vendor":"siemens","product":"sinumerik_828d_v4.7_firmware","name":"sinumerik 828d v4.7 firmware","label":"sinumerik_828d_v4.7_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP4 HF1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP4 HF1","eol":null,"hubHref":"/vendor/siemens/sinumerik_828d_v47"},{"vendor":"siemens","product":"sinumerik_840d_sl","name":"sinumerik 840d sl","label":"sinumerik_840d_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.5","noFixRecorded":false,"fixedIn":null},{"text":"4.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.5 | 4.5","eol":null,"hubHref":"/vendor/siemens/sinumerik_840d_sl"},{"vendor":"siemens","product":"sinumerik 840d sl v4.5 and prior","name":"SINUMERIK 840D sl V4.5 and prior","label":"sinumerik 840d sl v4.5 and prior","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.5 SP6 HF2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.5 SP6 HF2","eol":null,"hubHref":"/vendor/siemens/sinumerik_840d_sl_v45_and_prior"},{"vendor":"siemens","product":"sinumerik_840d_sl_v4.7_firmware","name":"sinumerik 840d sl v4.7 firmware","label":"sinumerik_840d_sl_v4.7_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP4 HF1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP4 HF1","eol":null,"hubHref":"/vendor/siemens/sinumerik_840d_sl_v47"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn hf","name":"SIPLUS ET 200MP IM 155-5 PN HF","label":"siplus et 200mp im 155-5 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_hf"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn hf t1 rail","name":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","label":"siplus et 200mp im 155-5 pn hf t1 rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_hf_t1_rail"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn st","name":"SIPLUS ET 200MP IM 155-5 PN ST","label":"siplus et 200mp im 155-5 pn st","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_st"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn st tx rail","name":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","label":"siplus et 200mp im 155-5 pn st tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_st_tx_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf","name":"SIPLUS ET 200SP IM 155-6 PN HF","label":"siplus et 200sp im 155-6 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf t1 rail","name":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","label":"siplus et 200sp im 155-6 pn hf t1 rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf_t1_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st","name":"SIPLUS ET 200SP IM 155-6 PN ST","label":"siplus et 200sp im 155-6 pn st","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st ba","name":"SIPLUS ET 200SP IM 155-6 PN ST BA","label":"siplus et 200sp im 155-6 pn st ba","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_ba"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st ba tx rail","name":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","label":"siplus et 200sp im 155-6 pn st ba tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_ba_tx_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st tx rail","name":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","label":"siplus et 200sp im 155-6 pn st tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_tx_rail"},{"vendor":"siemens","product":"sirius_act_3su1_firmware","name":"sirius act 3su1 firmware","label":"sirius_act_3su1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.1.0","eol":null,"hubHref":"/vendor/siemens/sirius_act_3su1"},{"vendor":"siemens","product":"sirius act 3su1 interface module profinet","name":"SIRIUS ACT 3SU1 interface module PROFINET","label":"sirius act 3su1 interface module profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.1.0","eol":null,"hubHref":"/vendor/siemens/sirius_act_3su1_interface_module_profinet"},{"vendor":"siemens","product":"sirius_motor_starter_m200d_profinet_firmware","name":"sirius motor starter m200d profinet firmware","label":"sirius_motor_starter_m200d_profinet_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sirius_motor_starter_m200d_profinet"},{"vendor":"siemens","product":"sirius_soft_starter_3rw44_pn_firmware","name":"sirius soft starter 3rw44 pn firmware","label":"sirius_soft_starter_3rw44_pn_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sirius_soft_starter_3rw44_pn"},{"vendor":"siemens","product":"sitop_psu8600_firmware","name":"sitop psu8600 firmware","label":"sitop_psu8600_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 1.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 1.2.0","eol":null,"hubHref":"/vendor/siemens/sitop_psu8600"},{"vendor":"siemens","product":"sitop psu8600 profinet","name":"SITOP PSU8600 PROFINET","label":"sitop psu8600 profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.2.0","eol":null,"hubHref":"/vendor/siemens/sitop_psu8600_profinet"},{"vendor":"siemens","product":"sitop ups1600 profinet (incl. siplus variants)","name":"SITOP UPS1600 PROFINET (incl. SIPLUS variants)","label":"sitop ups1600 profinet (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.2.0","eol":null,"hubHref":"/vendor/siemens/sitop_ups1600_profinet_incl_siplus_variants"},{"vendor":"siemens","product":"softnet_profinet_io_firmware","name":"softnet profinet io firmware","label":"softnet_profinet_io_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 14","noFixRecorded":false,"fixedIn":null},{"text":"14","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 14 | 14","eol":null,"hubHref":"/vendor/siemens/softnet_profinet_io"},{"vendor":"siemens","product":"softnet profinet io for pc-based windows systems","name":"Softnet PROFINET IO for PC-based Windows systems","label":"softnet profinet io for pc-based windows systems","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V14 SP1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V14 SP1","eol":null,"hubHref":"/vendor/siemens/softnet_profinet_io_for_pc-based_windows_systems"},{"vendor":"siemens","product":"ups1600_profinet_firmware","name":"ups1600 profinet firmware","label":"ups1600_profinet_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.2.0","eol":null,"hubHref":"/vendor/siemens/ups1600_profinet"}],"affectedCount":201,"eol":{"hasEol":false,"count":0},"references":[{"url":"http://www.securitytracker.com/id/1038463","label":"www.securitytracker.com/id/1038463","hostname":"www.securitytracker.com","tags":["VDB Entry","X Refsource SECTRACK","Third Party Advisory"]},{"url":"http://www.securityfocus.com/bid/98369","label":"www.securityfocus.com/bid/98369","hostname":"www.securityfocus.com","tags":["VDB Entry","X Refsource BID","Third Party Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf","hostname":"cert-portal.siemens.com","tags":["X Refsource CONFIRM","Vendor Advisory"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02","label":"ics-cert.us-cert.gov/advisories/ICSA-18-023-02","hostname":"ics-cert.us-cert.gov","tags":["X Refsource MISC","Third Party Advisory","US Government Resource"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf","hostname":"cert-portal.siemens.com","tags":["X Refsource CONFIRM","Vendor Advisory"]},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf","label":"www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf","hostname":"www.siemens.com","tags":["X Refsource CONFIRM","Broken Link"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf","hostname":"cert-portal.siemens.com","tags":["X Refsource MISC","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-293562.html","label":"cert-portal.siemens.com/productcert/html/ssa-293562.html","hostname":"cert-portal.siemens.com","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-284673.html","label":"cert-portal.siemens.com/productcert/html/ssa-284673.html","hostname":"cert-portal.siemens.com","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-546832.html","label":"cert-portal.siemens.com/productcert/html/ssa-546832.html","hostname":"cert-portal.siemens.com","tags":[]}],"lineage":{"upstream":[],"downstream":[],"duplicates":[],"related":[]},"timeline":[{"kind":"published","date":"2017-05-11T01:00:00.000Z","label":"Published","detail":"Vulnerability first disclosed.","source":null},{"kind":"modified","date":"2024-09-10T09:33:18.492Z","label":"Last modified","detail":"Vulnerability information updated.","source":null}],"risk":{"score":29,"level":"medium","profile":"Default","thresholds":{"critical":75,"high":50,"medium":25,"low":10}},"meta":{"dataAsOf":"2026-10-19T10:00:37.110Z","stale":false,"partial":false}}