{"schemaVersion":3,"id":"CVE-2019-10923","aliases":[],"status":"published","duplicateOf":null,"title":null,"description":"An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.","dates":{"published":"2019-10-10T13:49:24.000Z","modified":"2025-02-11T10:26:23.281Z","reserved":null,"kevAdded":[],"kevDue":[]},"cvss":{"headline":{"score":7.5,"severity":"high","version":"3.1","versionLabel":"v3.1","source":"CVE.org","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C","computed":false,"selection":"backend-summary"},"metrics":[{"version":"3.1","versionLabel":"v3.1","source":"CVE.org","score":7.5,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"NVD","score":7.5,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false},{"version":"2.0","versionLabel":"v2.0","source":"NVD","score":5,"severity":"medium","vector":"AV:N/AC:L/Au:N/C:N/I:N/A:P","exploitability":null,"impact":null,"computed":false}]},"epss":{"probability":0.01401,"percentile":0.72059,"severity":"low","asOf":"2026-10-18T00:00:00.000Z","change":{"pp":0,"baselineDate":"2026-09-18T00:00:00.000Z","baselineScore":0.01401},"history":[{"date":"2026-09-14T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-15T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-16T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-17T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-18T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01401,"percentile":0.72059}],"last30":[{"date":"2026-09-18T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01401,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01401,"percentile":0.72059}]},"kev":{"state":"not-listed","entries":[],"listedCount":0,"totalCatalogs":3,"catalogs":[{"source":"cisa","label":"CISA","listed":false,"entry":null},{"source":"enisa","label":"ENISA","listed":false,"entry":null},{"source":"circl","label":"CIRCL","listed":false,"entry":null}]},"ransomware":{"state":"none-recorded","sources":[]},"exploits":[],"exploitCount":0,"weaknesses":[{"id":"CWE-400","name":"Uncontrolled Resource Consumption","description":"The product does not properly control the allocation and maintenance of a limited resource.","type":"weakness","status":"Draft","abstraction":"Class","likelihoodOfExploit":"High","url":"https://cwe.mitre.org/data/definitions/400.html"}],"affected":[{"vendor":"siemens","product":"cp1604_firmware","name":"cp1604 firmware","label":"cp1604_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.8","eol":null,"hubHref":"/vendor/siemens/cp1604"},{"vendor":"siemens","product":"cp1616_firmware","name":"cp1616 firmware","label":"cp1616_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.8","eol":null,"hubHref":"/vendor/siemens/cp1616"},{"vendor":"siemens","product":"development/evaluation kits for profinet io: dk standard ethernet controller","name":"Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller","label":"development/evaluation kits for profinet io: dk standard ethernet controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.1.1 Patch 05","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.1.1 Patch 05","eol":null,"hubHref":null},{"vendor":"siemens","product":"development/evaluation kits for profinet io: ek-ertec 200","name":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200","label":"development/evaluation kits for profinet io: ek-ertec 200","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.5.0 Patch 01","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.5.0 Patch 01","eol":null,"hubHref":null},{"vendor":"siemens","product":"development/evaluation kits for profinet io: ek-ertec 200p","name":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P","label":"development/evaluation kits for profinet io: ek-ertec 200p","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.5.0","eol":null,"hubHref":null},{"vendor":"siemens","product":"dk_standard_ethernet_controller","name":"dk standard ethernet controller","label":"dk_standard_ethernet_controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.1.1","noFixRecorded":false,"fixedIn":null},{"text":"4.1.1","noFixRecorded":false,"fixedIn":null},{"text":"4.1.1:p4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.1.1 | 4.1.1 | 4.1.1:p4","eol":null,"hubHref":"/vendor/siemens/dk_standard_ethernet_controller"},{"vendor":"siemens","product":"ek-ertec_200_firmware","name":"ek-ertec 200 firmware","label":"ek-ertec_200_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.5.0","noFixRecorded":false,"fixedIn":null},{"text":"4.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.5.0 | 4.5.0","eol":null,"hubHref":"/vendor/siemens/ek-ertec_200"},{"vendor":"siemens","product":"ek-ertec_200p_firmware","name":"ek-ertec 200p firmware","label":"ek-ertec_200p_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.5.0","eol":null,"hubHref":"/vendor/siemens/ek-ertec_200p"},{"vendor":"siemens","product":"scalance_x-200irt_firmware","name":"scalance x-200irt firmware","label":"scalance_x-200irt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.1","eol":null,"hubHref":"/vendor/siemens/scalance_x-200irt"},{"vendor":"siemens","product":"scalance x-200irt family (incl. siplus net variants)","name":"SCALANCE X-200IRT family (incl. SIPLUS NET variants)","label":"scalance x-200irt family (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V5.2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V5.2.1","eol":null,"hubHref":"/vendor/siemens/scalance_x-200irt_family_incl_siplus_net_variants"},{"vendor":"siemens","product":"simatic_cp_1604_firmware","name":"simatic cp 1604 firmware","label":"simatic_cp_1604_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.8","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1604"},{"vendor":"siemens","product":"simatic_cp_1616_firmware","name":"simatic cp 1616 firmware","label":"simatic_cp_1616_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.8","eol":null,"hubHref":"/vendor/siemens/simatic_cp_1616"},{"vendor":"siemens","product":"simatic et 200m (incl. siplus variants)","name":"SIMATIC ET 200M (incl. SIPLUS variants)","label":"simatic et 200m (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200m_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_hf_firmware","name":"simatic et 200mp im 155-5 pn hf firmware","label":"simatic_et_200mp_im_155-5_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_hf"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_st_firmware","name":"simatic et 200mp im 155-5 pn st firmware","label":"simatic_et_200mp_im_155-5_pn_st_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_st"},{"vendor":"siemens","product":"simatic et 200pro im 154-3 pn hf","name":"SIMATIC ET 200pro IM 154-3 PN HF","label":"simatic et 200pro im 154-3 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-3_pn_hf"},{"vendor":"siemens","product":"simatic et 200pro im 154-4 pn hf","name":"SIMATIC ET 200pro IM 154-4 PN HF","label":"simatic et 200pro im 154-4 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-4_pn_hf"},{"vendor":"siemens","product":"simatic et 200pro im 154-8 pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8 PN/DP CPU","label":"simatic et 200pro im 154-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200pro im 154-8f pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8F PN/DP CPU","label":"simatic et 200pro im 154-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8f_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200pro im 154-8fx pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8FX PN/DP CPU","label":"simatic et 200pro im 154-8fx pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8fx_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200s im 151-8 pn/dp cpu","name":"SIMATIC ET 200S IM 151-8 PN/DP CPU","label":"simatic et 200s im 151-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_et_200s_im_151-8_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200s im 151-8f pn/dp cpu","name":"SIMATIC ET 200S IM 151-8F PN/DP CPU","label":"simatic et 200s im 151-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_et_200s_im_151-8f_pndp_cpu"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_hf_firmware","name":"simatic et 200sp im 155-6 pn hf firmware","label":"simatic_et_200sp_im_155-6_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_hf"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_st_firmware","name":"simatic et 200sp im 155-6 pn st firmware","label":"simatic_et_200sp_im_155-6_pn_st_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_st"},{"vendor":"siemens","product":"simatic et 200sp im 155-6 pn st ba","name":"SIMATIC ET 200SP IM 155-6 PN ST BA","label":"simatic et 200sp im 155-6 pn st ba","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_st_ba"},{"vendor":"siemens","product":"simatic et200ecopn, 16di, dc24v, 8xm12","name":"SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12","label":"simatic et200ecopn, 16di, dc24v, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_16di_dc24v_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 16do dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 16do dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_16do_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 4ao u/i 4xm12","name":"SIMATIC ET200ecoPN, 4AO U/I 4xM12","label":"simatic et200ecopn, 4ao u/i 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_4ao_ui_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8 dio, dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 8 dio, dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8_dio_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8 do, dc24v/2a, 8xm12","name":"SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12","label":"simatic et200ecopn, 8 do, dc24v/2a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8_do_dc24v2a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8ai; 4 u/i; 4 rtd/tc 8xm12","name":"SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12","label":"simatic et200ecopn, 8ai; 4 u/i; 4 rtd/tc 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8ai_4_ui_4_rtdtc_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8ai rtd/tc 8xm12","name":"SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12","label":"simatic et200ecopn, 8ai rtd/tc 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8ai_rtdtc_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8di, dc24v, 4xm12","name":"SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12","label":"simatic et200ecopn, 8di, dc24v, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8di_dc24v_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8di, dc24v, 8xm12","name":"SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12","label":"simatic et200ecopn, 8di, dc24v, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8di_dc24v_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/0,5a, 4xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12","label":"simatic et200ecopn, 8do, dc24v/0,5a, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v05a_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/1,3a, 4xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12","label":"simatic et200ecopn, 8do, dc24v/1,3a, 4xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v13a_4xm12"},{"vendor":"siemens","product":"simatic et200ecopn, 8do, dc24v/1,3a, 8xm12","name":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12","label":"simatic et200ecopn, 8do, dc24v/1,3a, 8xm12","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200ecopn_8do_dc24v13a_8xm12"},{"vendor":"siemens","product":"simatic et200ecopn: io-link master","name":"SIMATIC ET200ecoPN: IO-Link Master","label":"simatic et200ecopn: io-link master","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":null},{"vendor":"siemens","product":"simatic et200s (incl. siplus variants)","name":"SIMATIC ET200S (incl. SIPLUS variants)","label":"simatic et200s (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et200s_incl_siplus_variants"},{"vendor":"siemens","product":"simatic pn/pn coupler (incl. siplus net variants)","name":"SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)","label":"simatic pn/pn coupler (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pnpn_coupler_incl_siplus_net_variants"},{"vendor":"siemens","product":"simatic_s7-300_cpu_firmware","name":"simatic s7-300 cpu firmware","label":"simatic_s7-300_cpu_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu"},{"vendor":"siemens","product":"simatic_s7-300_cpu_312_ifm_firmware","name":"simatic s7-300 cpu 312 ifm firmware","label":"simatic_s7-300_cpu_312_ifm_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_312_ifm"},{"vendor":"siemens","product":"simatic_s7-300_cpu_313_firmware","name":"simatic s7-300 cpu 313 firmware","label":"simatic_s7-300_cpu_313_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_313"},{"vendor":"siemens","product":"simatic_s7-300_cpu_314_firmware","name":"simatic s7-300 cpu 314 firmware","label":"simatic_s7-300_cpu_314_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_314"},{"vendor":"siemens","product":"simatic_s7-300_cpu_314_ifm_firmware","name":"simatic s7-300 cpu 314 ifm firmware","label":"simatic_s7-300_cpu_314_ifm_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_314_ifm"},{"vendor":"siemens","product":"simatic s7-300 cpu 314c-2 pn/dp","name":"SIMATIC S7-300 CPU 314C-2 PN/DP","label":"simatic s7-300 cpu 314c-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_314c-2_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_315_firmware","name":"simatic s7-300 cpu 315 firmware","label":"simatic_s7-300_cpu_315_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315"},{"vendor":"siemens","product":"simatic_s7-300_cpu_315-2_dp_firmware","name":"simatic s7-300 cpu 315-2 dp firmware","label":"simatic_s7-300_cpu_315-2_dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315-2_dp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_315-2_pn\\/dp_firmware","name":"simatic s7-300 cpu 315-2 pn\\/dp firmware","label":"simatic_s7-300_cpu_315-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 315f-2 pn/dp","name":"SIMATIC S7-300 CPU 315F-2 PN/DP","label":"simatic s7-300 cpu 315f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315f-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 315t-3 pn/dp","name":"SIMATIC S7-300 CPU 315T-3 PN/DP","label":"simatic s7-300 cpu 315t-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315t-3_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_316-2_dp_firmware","name":"simatic s7-300 cpu 316-2 dp firmware","label":"simatic_s7-300_cpu_316-2_dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_316-2_dp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_317-2_pn\\/dp_firmware","name":"simatic s7-300 cpu 317-2 pn\\/dp firmware","label":"simatic_s7-300_cpu_317-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317f-2 pn/dp","name":"SIMATIC S7-300 CPU 317F-2 PN/DP","label":"simatic s7-300 cpu 317f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317f-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317t-3 pn/dp","name":"SIMATIC S7-300 CPU 317T-3 PN/DP","label":"simatic s7-300 cpu 317t-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317t-3_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317tf-3 pn/dp","name":"SIMATIC S7-300 CPU 317TF-3 PN/DP","label":"simatic s7-300 cpu 317tf-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317tf-3_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_318-2_firmware","name":"simatic s7-300 cpu 318-2 firmware","label":"simatic_s7-300_cpu_318-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.3.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_318-2"},{"vendor":"siemens","product":"simatic_s7-300_cpu_319-3_pn\\/dp_firmware","name":"simatic s7-300 cpu 319-3 pn\\/dp firmware","label":"simatic_s7-300_cpu_319-3_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_319-3_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 319f-3 pn/dp","name":"SIMATIC S7-300 CPU 319F-3 PN/DP","label":"simatic s7-300 cpu 319f-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_319f-3_pndp"},{"vendor":"siemens","product":"simatic s7-400 cpu 412-2 pn v7","name":"SIMATIC S7-400 CPU 412-2 PN V7","label":"simatic s7-400 cpu 412-2 pn v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_412-2_pn_v7"},{"vendor":"siemens","product":"simatic s7-400 cpu 414-3 pn/dp v7","name":"SIMATIC S7-400 CPU 414-3 PN/DP V7","label":"simatic s7-400 cpu 414-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_414-3_pndp_v7"},{"vendor":"siemens","product":"simatic s7-400 cpu 414f-3 pn/dp v7","name":"SIMATIC S7-400 CPU 414F-3 PN/DP V7","label":"simatic s7-400 cpu 414f-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_414f-3_pndp_v7"},{"vendor":"siemens","product":"simatic s7-400 cpu 416-3 pn/dp v7","name":"SIMATIC S7-400 CPU 416-3 PN/DP V7","label":"simatic s7-400 cpu 416-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_416-3_pndp_v7"},{"vendor":"siemens","product":"simatic s7-400 cpu 416f-3 pn/dp v7","name":"SIMATIC S7-400 CPU 416F-3 PN/DP V7","label":"simatic s7-400 cpu 416f-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_416f-3_pndp_v7"},{"vendor":"siemens","product":"simatic s7-400 pn/dp v6 and below cpu family (incl. siplus variants)","name":"SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)","label":"simatic s7-400 pn/dp v6 and below cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_pndp_v6_and_below_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_winac_rtx_2010","name":"simatic winac rtx 2010","label":"simatic_winac_rtx_2010","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2010 SP3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2010 SP3","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_2010"},{"vendor":"siemens","product":"simatic_winac_rtx_\\(f\\)_firmware","name":"simatic winac rtx \\(f\\) firmware","label":"simatic_winac_rtx_\\(f\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2010","noFixRecorded":false,"fixedIn":null},{"text":"2010","noFixRecorded":false,"fixedIn":null},{"text":"2010:sp1","noFixRecorded":false,"fixedIn":null},{"text":"2010:sp2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2010 | 2010 | 2010:sp1 | 2010:sp2","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_f"},{"vendor":"siemens","product":"simatic_winac_rtx_\\(f\\)_2010_firmware","name":"simatic winac rtx \\(f\\) 2010 firmware","label":"simatic_winac_rtx_\\(f\\)_2010_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V2010 SP3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2010 SP3","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_f_2010"},{"vendor":"siemens","product":"simotion_firmware","name":"simotion firmware","label":"simotion_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simotion"},{"vendor":"siemens","product":"sinamics_dcm_firmware","name":"sinamics dcm firmware","label":"sinamics_dcm_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.5 HF1","noFixRecorded":false,"fixedIn":null},{"text":"< 1.5","noFixRecorded":false,"fixedIn":null},{"text":"1.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.5 HF1 | < 1.5 | 1.5","eol":null,"hubHref":"/vendor/siemens/sinamics_dcm"},{"vendor":"siemens","product":"sinamics_dcp_firmware","name":"sinamics dcp firmware","label":"sinamics_dcp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V1.3","noFixRecorded":false,"fixedIn":null},{"text":"< 1.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V1.3 | < 1.3","eol":null,"hubHref":"/vendor/siemens/sinamics_dcp"},{"vendor":"siemens","product":"sinamics_g110m_firmware","name":"sinamics g110m firmware","label":"sinamics_g110m_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_g110m"},{"vendor":"siemens","product":"sinamics g110m v4.7 control unit","name":"SINAMICS G110M V4.7 Control Unit","label":"sinamics g110m v4.7 control unit","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP10 HF5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP10 HF5","eol":null,"hubHref":"/vendor/siemens/sinamics_g110m_v47_control_unit"},{"vendor":"siemens","product":"sinamics_g120_firmware","name":"sinamics g120 firmware","label":"sinamics_g120_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_g120"},{"vendor":"siemens","product":"sinamics g120 v4.7 control unit (incl. siplus variants)","name":"SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants)","label":"sinamics g120 v4.7 control unit (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 SP10 HF5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 SP10 HF5","eol":null,"hubHref":"/vendor/siemens/sinamics_g120_v47_control_unit_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics_g130_firmware","name":"sinamics g130 firmware","label":"sinamics_g130_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.7 HF29","noFixRecorded":false,"fixedIn":null},{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.7 HF29 | < 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_g130"},{"vendor":"siemens","product":"sinamics_g150_firmware","name":"sinamics g150 firmware","label":"sinamics_g150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.7 HF29","noFixRecorded":false,"fixedIn":null},{"text":"< 4.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.7 HF29 | < 4.8","eol":null,"hubHref":"/vendor/siemens/sinamics_g150"},{"vendor":"siemens","product":"sinamics_gh150_firmware","name":"sinamics gh150 firmware","label":"sinamics_gh150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.8","noFixRecorded":false,"fixedIn":null},{"text":"4.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8 | 4.8","eol":null,"hubHref":"/vendor/siemens/sinamics_gh150"},{"vendor":"siemens","product":"sinamics gh150 v4.7 (control unit)","name":"SINAMICS GH150 V4.7 (Control Unit)","label":"sinamics gh150 v4.7 (control unit)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_gh150_v47_control_unit"},{"vendor":"siemens","product":"sinamics_gl150_firmware","name":"sinamics gl150 firmware","label":"sinamics_gl150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.8","noFixRecorded":false,"fixedIn":null},{"text":"4.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8 | 4.8","eol":null,"hubHref":"/vendor/siemens/sinamics_gl150"},{"vendor":"siemens","product":"sinamics gl150 v4.7 (control unit)","name":"SINAMICS GL150 V4.7 (Control Unit)","label":"sinamics gl150 v4.7 (control unit)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_gl150_v47_control_unit"},{"vendor":"siemens","product":"sinamics_gm150_firmware","name":"sinamics gm150 firmware","label":"sinamics_gm150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.8","noFixRecorded":false,"fixedIn":null},{"text":"4.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8 | 4.8","eol":null,"hubHref":"/vendor/siemens/sinamics_gm150"},{"vendor":"siemens","product":"sinamics gm150 v4.7 (control unit)","name":"SINAMICS GM150 V4.7 (Control Unit)","label":"sinamics gm150 v4.7 (control unit)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_gm150_v47_control_unit"},{"vendor":"siemens","product":"sinamics s110 control unit","name":"SINAMICS S110 Control Unit","label":"sinamics s110 control unit","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_s110_control_unit"},{"vendor":"siemens","product":"sinamics_s120_firmware","name":"sinamics s120 firmware","label":"sinamics_s120_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_s120"},{"vendor":"siemens","product":"sinamics s120 v4.7 control unit and cbe20 (incl. siplus variants)","name":"SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants)","label":"sinamics s120 v4.7 control unit and cbe20 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF34","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF34","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_v47_control_unit_and_cbe20_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics_s150_firmware","name":"sinamics s150 firmware","label":"sinamics_s150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V4.7 HF29","noFixRecorded":false,"fixedIn":null},{"text":"< 4.8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.7 HF29 | < 4.8","eol":null,"hubHref":"/vendor/siemens/sinamics_s150"},{"vendor":"siemens","product":"sinamics_sl150_firmware","name":"sinamics sl150 firmware","label":"sinamics_sl150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 4.7","noFixRecorded":false,"fixedIn":null},{"text":"4.7","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.7 | 4.7","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150"},{"vendor":"siemens","product":"sinamics sl150 v4.7 (control unit)","name":"SINAMICS SL150 V4.7 (Control Unit)","label":"sinamics sl150 v4.7 (control unit)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.7 HF33","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.7 HF33","eol":null,"hubHref":"/vendor/siemens/sinamics_sl150_v47_control_unit"},{"vendor":"siemens","product":"sinamics sm120 v4.7 (control unit)","name":"SINAMICS SM120 V4.7 (Control Unit)","label":"sinamics sm120 v4.7 (control unit)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_sm120_v47_control_unit"},{"vendor":"siemens","product":"sinumerik_828d_firmware","name":"sinumerik 828d firmware","label":"sinumerik_828d_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP5","noFixRecorded":false,"fixedIn":null},{"text":"< 4.8","noFixRecorded":false,"fixedIn":null},{"text":"4.8","noFixRecorded":false,"fixedIn":null},{"text":"4.8:sp1","noFixRecorded":false,"fixedIn":null},{"text":"4.8:sp2","noFixRecorded":false,"fixedIn":null},{"text":"4.8:sp3","noFixRecorded":false,"fixedIn":null},{"text":"4.8:sp4","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP5 | < 4.8 | 4.8 | 4.8:sp1 | 4.8:sp2 | 4.8:sp3 | 4.8:sp4","eol":null,"hubHref":"/vendor/siemens/sinumerik_828d"},{"vendor":"siemens","product":"sinumerik_840d_sl","name":"sinumerik 840d sl","label":"sinumerik_840d_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.8 SP5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.8 SP5","eol":null,"hubHref":"/vendor/siemens/sinumerik_840d_sl"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn hf","name":"SIPLUS ET 200MP IM 155-5 PN HF","label":"siplus et 200mp im 155-5 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_hf"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn hf t1 rail","name":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","label":"siplus et 200mp im 155-5 pn hf t1 rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_hf_t1_rail"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn st","name":"SIPLUS ET 200MP IM 155-5 PN ST","label":"siplus et 200mp im 155-5 pn st","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_st"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn st tx rail","name":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","label":"siplus et 200mp im 155-5 pn st tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_st_tx_rail"},{"vendor":"siemens","product":"siplus et 200s im 151-8 pn/dp cpu","name":"SIPLUS ET 200S IM 151-8 PN/DP CPU","label":"siplus et 200s im 151-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/siplus_et_200s_im_151-8_pndp_cpu"},{"vendor":"siemens","product":"siplus et 200s im 151-8f pn/dp cpu","name":"SIPLUS ET 200S IM 151-8F PN/DP CPU","label":"siplus et 200s im 151-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/siplus_et_200s_im_151-8f_pndp_cpu"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf","name":"SIPLUS ET 200SP IM 155-6 PN HF","label":"siplus et 200sp im 155-6 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf t1 rail","name":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","label":"siplus et 200sp im 155-6 pn hf t1 rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.2.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf_t1_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st","name":"SIPLUS ET 200SP IM 155-6 PN ST","label":"siplus et 200sp im 155-6 pn st","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st ba","name":"SIPLUS ET 200SP IM 155-6 PN ST BA","label":"siplus et 200sp im 155-6 pn st ba","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_ba"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st ba tx rail","name":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","label":"siplus et 200sp im 155-6 pn st ba tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_ba_tx_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn st tx rail","name":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","label":"siplus et 200sp im 155-6 pn st tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_st_tx_rail"},{"vendor":"siemens","product":"siplus s7-300 cpu 314c-2 pn/dp","name":"SIPLUS S7-300 CPU 314C-2 PN/DP","label":"siplus s7-300 cpu 314c-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.3.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.3.17","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_314c-2_pndp"},{"vendor":"siemens","product":"siplus_s7-300_cpu_315-2_pn\\/dp_firmware","name":"siplus s7-300 cpu 315-2 pn\\/dp firmware","label":"siplus_s7-300_cpu_315-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_315-2_pndp"},{"vendor":"siemens","product":"siplus s7-300 cpu 315f-2 pn/dp","name":"SIPLUS S7-300 CPU 315F-2 PN/DP","label":"siplus s7-300 cpu 315f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_315f-2_pndp"},{"vendor":"siemens","product":"siplus_s7-300_cpu_317-2_pn\\/dp_firmware","name":"siplus s7-300 cpu 317-2 pn\\/dp firmware","label":"siplus_s7-300_cpu_317-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_317-2_pndp"},{"vendor":"siemens","product":"siplus s7-300 cpu 317f-2 pn/dp","name":"SIPLUS S7-300 CPU 317F-2 PN/DP","label":"siplus s7-300 cpu 317f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V3.2.17","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V3.2.17","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_317f-2_pndp"},{"vendor":"siemens","product":"siplus s7-400 cpu 414-3 pn/dp v7","name":"SIPLUS S7-400 CPU 414-3 PN/DP V7","label":"siplus s7-400 cpu 414-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.3","eol":null,"hubHref":"/vendor/siemens/siplus_s7-400_cpu_414-3_pndp_v7"},{"vendor":"siemens","product":"siplus s7-400 cpu 416-3 pn/dp v7","name":"SIPLUS S7-400 CPU 416-3 PN/DP V7","label":"siplus s7-400 cpu 416-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0.3","eol":null,"hubHref":"/vendor/siemens/siplus_s7-400_cpu_416-3_pndp_v7"}],"affectedCount":111,"eol":{"hasEol":false,"count":0},"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf","hostname":"cert-portal.siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-349422.html","label":"cert-portal.siemens.com/productcert/html/ssa-349422.html","hostname":"cert-portal.siemens.com","tags":[]}],"lineage":{"upstream":[],"downstream":[],"duplicates":[],"related":[]},"timeline":[{"kind":"published","date":"2019-10-10T13:49:24.000Z","label":"Published","detail":"Vulnerability first disclosed.","source":null},{"kind":"modified","date":"2025-02-11T10:26:23.281Z","label":"Last modified","detail":"Vulnerability information updated.","source":null}],"risk":{"score":30,"level":"medium","profile":"Default","thresholds":{"critical":75,"high":50,"medium":25,"low":10}},"meta":{"dataAsOf":"2026-10-19T12:11:33.928Z","stale":false,"partial":false}}