{"schemaVersion":3,"id":"CVE-2019-19300","aliases":[],"status":"published","duplicateOf":null,"title":null,"description":"A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET 200eco PN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET 200eco PN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.","dates":{"published":"2020-04-14T00:00:00.000Z","modified":"2025-07-08T10:32:10.489Z","reserved":null,"kevAdded":[],"kevDue":[]},"cvss":{"headline":{"score":7.5,"severity":"high","version":"3.1","versionLabel":"v3.1","source":"CVE.org","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C","computed":false,"selection":"backend-summary"},"metrics":[{"version":"3.1","versionLabel":"v3.1","source":"CVE.org","score":7.5,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"NVD","score":7.5,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false},{"version":"2.0","versionLabel":"v2.0","source":"NVD","score":5,"severity":"medium","vector":"AV:N/AC:L/Au:N/C:N/I:N/A:P","exploitability":null,"impact":null,"computed":false}]},"epss":{"probability":0.01722,"percentile":0.77153,"severity":"low","asOf":"2026-10-19T00:00:00.000Z","change":{"pp":0,"baselineDate":"2026-09-19T00:00:00.000Z","baselineScore":0.01722},"history":[{"date":"2026-09-14T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-15T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-16T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-17T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-18T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.01722,"percentile":0.77153}],"last30":[{"date":"2026-09-19T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01722,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.01722,"percentile":0.77153}]},"kev":{"state":"not-listed","entries":[],"listedCount":0,"totalCatalogs":3,"catalogs":[{"source":"cisa","label":"CISA","listed":false,"entry":null},{"source":"enisa","label":"ENISA","listed":false,"entry":null},{"source":"circl","label":"CIRCL","listed":false,"entry":null}]},"ransomware":{"state":"none-recorded","sources":[]},"exploits":[],"exploitCount":0,"weaknesses":[{"id":"CWE-400","name":"Uncontrolled Resource Consumption","description":"The product does not properly control the allocation and maintenance of a limited resource.","type":"weakness","status":"Draft","abstraction":"Class","likelihoodOfExploit":"High","url":"https://cwe.mitre.org/data/definitions/400.html"}],"affected":[{"vendor":"siemens","product":"development/evaluation kits for profinet io: ek-ertec 200","name":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200","label":"development/evaluation kits for profinet io: ek-ertec 200","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":null},{"vendor":"siemens","product":"development/evaluation kits for profinet io: ek-ertec 200p","name":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P","label":"development/evaluation kits for profinet io: ek-ertec 200p","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":null},{"vendor":"siemens","product":"ktk_ate530s_firmware","name":"ktk ate530s firmware","label":"ktk_ate530s_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/ktk_ate530s"},{"vendor":"siemens","product":"sidoor_atd430w_firmware","name":"sidoor atd430w firmware","label":"sidoor_atd430w_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sidoor_atd430w"},{"vendor":"siemens","product":"sidoor_ate530s_coated_firmware","name":"sidoor ate530s coated firmware","label":"sidoor_ate530s_coated_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sidoor_ate530s_coated"},{"vendor":"siemens","product":"sidoor_ate531s_firmware","name":"sidoor ate531s firmware","label":"sidoor_ate531s_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sidoor_ate531s"},{"vendor":"siemens","product":"simatic et 200al im 157-1 pn","name":"SIMATIC ET 200AL IM 157-1 PN","label":"simatic et 200al im 157-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200al_im_157-1_pn"},{"vendor":"siemens","product":"simatic et 200eco pn, ai 8xrtd/tc, m12-l","name":"SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L","label":"simatic et 200eco pn, ai 8xrtd/tc, m12-l","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V5.1.1, < V5.1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V5.1.1, < V5.1.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200eco_pn_ai_8xrtdtc_m12-l"},{"vendor":"siemens","product":"simatic et 200eco pn, cm 4x io-link, m12-l","name":"SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L","label":"simatic et 200eco pn, cm 4x io-link, m12-l","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V5.1.1, < V5.1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V5.1.1, < V5.1.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200eco_pn_cm_4x_io-link_m12-l"},{"vendor":"siemens","product":"simatic et 200eco pn, cm 8x io-link, m12-l","name":"SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L","label":"simatic et 200eco pn, cm 8x io-link, m12-l","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V5.1.1, < V5.1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V5.1.1, < V5.1.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200eco_pn_cm_8x_io-link_m12-l"},{"vendor":"siemens","product":"simatic et 200eco pn, di 16x24vdc, m12-l","name":"SIMATIC ET 200eco PN, DI 16x24VDC, M12-L","label":"simatic et 200eco pn, di 16x24vdc, m12-l","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V5.1.1, < V5.1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V5.1.1, < V5.1.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200eco_pn_di_16x24vdc_m12-l"},{"vendor":"siemens","product":"simatic et 200eco pn, di 8x24vdc, m12-l","name":"SIMATIC ET 200eco PN, DI 8x24VDC, M12-L","label":"simatic et 200eco pn, di 8x24vdc, m12-l","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V5.1.1, < V5.1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V5.1.1, < V5.1.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200eco_pn_di_8x24vdc_m12-l"},{"vendor":"siemens","product":"simatic et 200eco pn, diq 16x24vdc/2a, m12-l","name":"SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L","label":"simatic et 200eco pn, diq 16x24vdc/2a, m12-l","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V5.1.1, < V5.1.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V5.1.1, < V5.1.3","eol":null,"hubHref":"/vendor/siemens/simatic_et_200eco_pn_diq_16x24vdc2a_m12-l"},{"vendor":"siemens","product":"simatic et 200eco pn, dq 8x24vdc/0,5a, m12-l","name":"SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L","label":"simatic et 200eco pn, dq 8x24vdc/0,5a, m12-l","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V5.1.1, < V5.1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V5.1.1, < V5.1.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200eco_pn_dq_8x24vdc05a_m12-l"},{"vendor":"siemens","product":"simatic et 200eco pn, dq 8x24vdc/2a, m12-l","name":"SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L","label":"simatic et 200eco pn, dq 8x24vdc/2a, m12-l","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V5.1.1, < V5.1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V5.1.1, < V5.1.2","eol":null,"hubHref":"/vendor/siemens/simatic_et_200eco_pn_dq_8x24vdc2a_m12-l"},{"vendor":"siemens","product":"simatic_et_200mp_im_155-5_pn_hf_firmware","name":"simatic et 200mp im 155-5 pn hf firmware","label":"simatic_et_200mp_im_155-5_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200mp_im_155-5_pn_hf"},{"vendor":"siemens","product":"simatic et 200pro im 154-8 pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8 PN/DP CPU","label":"simatic et 200pro im 154-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200pro im 154-8f pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8F PN/DP CPU","label":"simatic et 200pro im 154-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8f_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200pro im 154-8fx pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8FX PN/DP CPU","label":"simatic et 200pro im 154-8fx pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8fx_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200s im 151-8 pn/dp cpu","name":"SIMATIC ET 200S IM 151-8 PN/DP CPU","label":"simatic et 200s im 151-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200s_im_151-8_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200s im 151-8f pn/dp cpu","name":"SIMATIC ET 200S IM 151-8F PN/DP CPU","label":"simatic et 200s im 151-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200s_im_151-8f_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200sp im 155-6 mf hf","name":"SIMATIC ET 200SP IM 155-6 MF HF","label":"simatic et 200sp im 155-6 mf hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_mf_hf"},{"vendor":"siemens","product":"simatic et 200sp im 155-6 pn ha (incl. siplus variants)","name":"SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)","label":"simatic et 200sp im 155-6 pn ha (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_ha_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn_hf_firmware","name":"simatic et 200sp im 155-6 pn hf firmware","label":"simatic_et_200sp_im_155-6_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn_hf"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn\\/2_hf_firmware","name":"simatic et 200sp im 155-6 pn\\/2 hf firmware","label":"simatic_et_200sp_im_155-6_pn\\/2_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn2_hf"},{"vendor":"siemens","product":"simatic_et_200sp_im_155-6_pn\\/3_hf_firmware","name":"simatic et 200sp im 155-6 pn\\/3 hf firmware","label":"simatic_et_200sp_im_155-6_pn\\/3_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_im_155-6_pn3_hf"},{"vendor":"siemens","product":"simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware","name":"simatic et 200sp open controller cpu 1515sp pc firmware","label":"simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_open_controller_cpu_1515sp_pc"},{"vendor":"siemens","product":"simatic et 200sp open controller cpu 1515sp pc (incl. siplus variants)","name":"SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)","label":"simatic et 200sp open controller cpu 1515sp pc (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_open_controller_cpu_1515sp_pc_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware","name":"simatic et 200sp open controller cpu 1515sp pc2 firmware","label":"simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_open_controller_cpu_1515sp_pc2"},{"vendor":"siemens","product":"simatic et 200sp open controller cpu 1515sp pc2 (incl. siplus variants)","name":"SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)","label":"simatic et 200sp open controller cpu 1515sp pc2 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.0","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_open_controller_cpu_1515sp_pc2_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_et200mp_im155-5_pn_hf_firmware","name":"simatic et200mp im155-5 pn hf firmware","label":"simatic_et200mp_im155-5_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≤ 4.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≤ 4.2","eol":null,"hubHref":"/vendor/siemens/simatic_et200mp_im155-5_pn_hf"},{"vendor":"siemens","product":"simatic_et200sp_im155-6_pn_hf_firmware","name":"simatic et200sp im155-6 pn hf firmware","label":"simatic_et200sp_im155-6_pn_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≤ 4.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≤ 4.2","eol":null,"hubHref":"/vendor/siemens/simatic_et200sp_im155-6_pn_hf"},{"vendor":"siemens","product":"simatic_et200sp_im155-6_pn\\/2_hf_firmware","name":"simatic et200sp im155-6 pn\\/2 hf firmware","label":"simatic_et200sp_im155-6_pn\\/2_hf_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"≤ 4.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"≤ 4.2","eol":null,"hubHref":"/vendor/siemens/simatic_et200sp_im155-6_pn2_hf"},{"vendor":"siemens","product":"simatic_micro-drive_pdc_firmware","name":"simatic micro-drive pdc firmware","label":"simatic_micro-drive_pdc_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_micro-drive_pdc"},{"vendor":"siemens","product":"simatic pn/mf coupler","name":"SIMATIC PN/MF Coupler","label":"simatic pn/mf coupler","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pnmf_coupler"},{"vendor":"siemens","product":"simatic_pn\\/pn_coupler_firmware","name":"simatic pn\\/pn coupler firmware","label":"simatic_pn\\/pn_coupler_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions >= V4.2","noFixRecorded":false,"fixedIn":null},{"text":"≤ 4.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions >= V4.2 | ≤ 4.2","eol":null,"hubHref":"/vendor/siemens/simatic_pnpn_coupler"},{"vendor":"siemens","product":"simatic s7-1200 cpu family (incl. siplus variants)","name":"SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","label":"simatic s7-1200 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V4.4.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V4.4.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1200_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_s7-1500","name":"simatic s7-1500","label":"simatic_s7-1500","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1511-1 pn","name":"SIMATIC S7-1500 CPU 1511-1 PN","label":"simatic s7-1500 cpu 1511-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1511-1_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1511f-1 pn","name":"SIMATIC S7-1500 CPU 1511F-1 PN","label":"simatic s7-1500 cpu 1511f-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1511f-1_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1513-1 pn","name":"SIMATIC S7-1500 CPU 1513-1 PN","label":"simatic s7-1500 cpu 1513-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1513-1_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1513f-1 pn","name":"SIMATIC S7-1500 CPU 1513F-1 PN","label":"simatic s7-1500 cpu 1513f-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1513f-1_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1515-2 pn","name":"SIMATIC S7-1500 CPU 1515-2 PN","label":"simatic s7-1500 cpu 1515-2 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1515-2_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1515f-2 pn","name":"SIMATIC S7-1500 CPU 1515F-2 PN","label":"simatic s7-1500 cpu 1515f-2 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1515f-2_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1516-3 pn/dp","name":"SIMATIC S7-1500 CPU 1516-3 PN/DP","label":"simatic s7-1500 cpu 1516-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1516-3_pndp"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1516f-3 pn/dp","name":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","label":"simatic s7-1500 cpu 1516f-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1516f-3_pndp"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1517-3 pn/dp","name":"SIMATIC S7-1500 CPU 1517-3 PN/DP","label":"simatic s7-1500 cpu 1517-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1517-3_pndp"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1517f-3 pn/dp","name":"SIMATIC S7-1500 CPU 1517F-3 PN/DP","label":"simatic s7-1500 cpu 1517f-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1517f-3_pndp"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1518-4 pn/dp","name":"SIMATIC S7-1500 CPU 1518-4 PN/DP","label":"simatic s7-1500 cpu 1518-4 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1518-4_pndp"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1518f-4 pn/dp","name":"SIMATIC S7-1500 CPU 1518F-4 PN/DP","label":"simatic s7-1500 cpu 1518f-4 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1518f-4_pndp"},{"vendor":"siemens","product":"simatic s7-1500 cpu family (incl. related et 200 cpus and siplus variants)","name":"SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants)","label":"simatic s7-1500 cpu family (incl. related et 200 cpus and siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_family_incl_related_et_200_cpus_and_siplus_variants"},{"vendor":"siemens","product":"simatic_s7-1500_software_controller","name":"simatic s7-1500 software controller","label":"simatic_s7-1500_software_controller","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V2.0","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_software_controller"},{"vendor":"siemens","product":"simatic s7-300 cpu 314c-2 pn/dp","name":"SIMATIC S7-300 CPU 314C-2 PN/DP","label":"simatic s7-300 cpu 314c-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_314c-2_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_315-2_pn\\/dp_firmware","name":"simatic s7-300 cpu 315-2 pn\\/dp firmware","label":"simatic_s7-300_cpu_315-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 315f-2 pn/dp","name":"SIMATIC S7-300 CPU 315F-2 PN/DP","label":"simatic s7-300 cpu 315f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315f-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 315t-3 pn/dp","name":"SIMATIC S7-300 CPU 315T-3 PN/DP","label":"simatic s7-300 cpu 315t-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315t-3_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_317-2_pn\\/dp_firmware","name":"simatic s7-300 cpu 317-2 pn\\/dp firmware","label":"simatic_s7-300_cpu_317-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317f-2 pn/dp","name":"SIMATIC S7-300 CPU 317F-2 PN/DP","label":"simatic s7-300 cpu 317f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317f-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317t-3 pn/dp","name":"SIMATIC S7-300 CPU 317T-3 PN/DP","label":"simatic s7-300 cpu 317t-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317t-3_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317tf-3 pn/dp","name":"SIMATIC S7-300 CPU 317TF-3 PN/DP","label":"simatic s7-300 cpu 317tf-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317tf-3_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_319-3_pn\\/dp_firmware","name":"simatic s7-300 cpu 319-3 pn\\/dp firmware","label":"simatic_s7-300_cpu_319-3_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_319-3_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 319f-3 pn/dp","name":"SIMATIC S7-300 CPU 319F-3 PN/DP","label":"simatic s7-300 cpu 319f-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_319f-3_pndp"},{"vendor":"siemens","product":"simatic s7-400 h v6 and below cpu family (incl. siplus variants)","name":"SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)","label":"simatic s7-400 h v6 and below cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_h_v6_and_below_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-400 pn/dp v7 cpu family (incl. siplus variants)","name":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","label":"simatic s7-400 pn/dp v7 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_pndp_v7_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-410 v10 cpu family (incl. siplus variants)","name":"SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)","label":"simatic s7-410 v10 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V10.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V10.2","eol":null,"hubHref":"/vendor/siemens/simatic_s7-410_v10_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-410 v8 cpu family (incl. siplus variants)","name":"SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)","label":"simatic s7-410 v8 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-410_v8_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic_tdc_cp51m1_firmware","name":"simatic tdc cp51m1 firmware","label":"simatic_tdc_cp51m1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_tdc_cp51m1"},{"vendor":"siemens","product":"simatic_tdc_cpu555_firmware","name":"simatic tdc cpu555 firmware","label":"simatic_tdc_cpu555_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_tdc_cpu555"},{"vendor":"siemens","product":"simatic_winac_rtx_2010","name":"simatic winac rtx 2010","label":"simatic_winac_rtx_2010","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_2010"},{"vendor":"siemens","product":"simatic_winac_rtx_\\(f\\)_2010_firmware","name":"simatic winac rtx \\(f\\) 2010 firmware","label":"simatic_winac_rtx_\\(f\\)_2010_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_winac_rtx_f_2010"},{"vendor":"siemens","product":"sinamics s/g control unit w. profinet","name":"SINAMICS S/G Control Unit w. PROFINET","label":"sinamics s/g control unit w. profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_sg_control_unit_w_profinet"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn hf","name":"SIPLUS ET 200MP IM 155-5 PN HF","label":"siplus et 200mp im 155-5 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_hf"},{"vendor":"siemens","product":"siplus et 200mp im 155-5 pn hf t1 rail","name":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","label":"siplus et 200mp im 155-5 pn hf t1 rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200mp_im_155-5_pn_hf_t1_rail"},{"vendor":"siemens","product":"siplus et 200s im 151-8 pn/dp cpu","name":"SIPLUS ET 200S IM 151-8 PN/DP CPU","label":"siplus et 200s im 151-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200s_im_151-8_pndp_cpu"},{"vendor":"siemens","product":"siplus et 200s im 151-8f pn/dp cpu","name":"SIPLUS ET 200S IM 151-8F PN/DP CPU","label":"siplus et 200s im 151-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200s_im_151-8f_pndp_cpu"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf","name":"SIPLUS ET 200SP IM 155-6 PN HF","label":"siplus et 200sp im 155-6 pn hf","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf t1 rail","name":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","label":"siplus et 200sp im 155-6 pn hf t1 rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf_t1_rail"},{"vendor":"siemens","product":"siplus et 200sp im 155-6 pn hf tx rail","name":"SIPLUS ET 200SP IM 155-6 PN HF TX RAIL","label":"siplus et 200sp im 155-6 pn hf tx rail","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V4.2.0","noFixRecorded":true,"fixedIn":null}],"versionsText":"≥ V4.2.0 (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200sp_im_155-6_pn_hf_tx_rail"},{"vendor":"siemens","product":"siplus net pn/pn coupler","name":"SIPLUS NET PN/PN Coupler","label":"siplus net pn/pn coupler","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions >= V4.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions >= V4.2","eol":null,"hubHref":"/vendor/siemens/siplus_net_pnpn_coupler"},{"vendor":"siemens","product":"siplus s7-300 cpu 314c-2 pn/dp","name":"SIPLUS S7-300 CPU 314C-2 PN/DP","label":"siplus s7-300 cpu 314c-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_314c-2_pndp"},{"vendor":"siemens","product":"siplus_s7-300_cpu_315-2_pn\\/dp_firmware","name":"siplus s7-300 cpu 315-2 pn\\/dp firmware","label":"siplus_s7-300_cpu_315-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_315-2_pndp"},{"vendor":"siemens","product":"siplus s7-300 cpu 315f-2 pn/dp","name":"SIPLUS S7-300 CPU 315F-2 PN/DP","label":"siplus s7-300 cpu 315f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_315f-2_pndp"},{"vendor":"siemens","product":"siplus_s7-300_cpu_317-2_pn\\/dp_firmware","name":"siplus s7-300 cpu 317-2 pn\\/dp firmware","label":"siplus_s7-300_cpu_317-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_317-2_pndp"},{"vendor":"siemens","product":"siplus s7-300 cpu 317f-2 pn/dp","name":"SIPLUS S7-300 CPU 317F-2 PN/DP","label":"siplus s7-300 cpu 317f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_317f-2_pndp"}],"affectedCount":84,"eol":{"hasEol":false,"count":0},"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf","hostname":"cert-portal.siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-593272.html","label":"cert-portal.siemens.com/productcert/html/ssa-593272.html","hostname":"cert-portal.siemens.com","tags":[]}],"lineage":{"upstream":[],"downstream":[],"duplicates":[],"related":[]},"timeline":[{"kind":"published","date":"2020-04-14T00:00:00.000Z","label":"Published","detail":"Vulnerability first disclosed.","source":null},{"kind":"modified","date":"2025-07-08T10:32:10.489Z","label":"Last modified","detail":"Vulnerability information updated.","source":null}],"risk":{"score":30,"level":"medium","profile":"Default","thresholds":{"critical":75,"high":50,"medium":25,"low":10}},"meta":{"dataAsOf":"2026-10-20T03:32:35.258Z","stale":false,"partial":false}}