{"schemaVersion":3,"id":"CVE-2020-25226","aliases":[],"status":"published","duplicateOf":null,"title":null,"description":"A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.","dates":{"published":"2021-01-12T20:18:33.000Z","modified":"2024-08-04T15:33:04.885Z","reserved":null,"kevAdded":[],"kevDue":[]},"cvss":{"headline":{"score":10,"severity":"high","version":"2.0","versionLabel":"v2.0","source":"NVD","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","computed":false,"selection":"backend-summary"},"metrics":[{"version":"3.1","versionLabel":"v3.1","source":"NVD","score":9.8,"severity":"critical","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","exploitability":null,"impact":null,"computed":false},{"version":"2.0","versionLabel":"v2.0","source":"NVD","score":10,"severity":"high","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","exploitability":null,"impact":null,"computed":false}]},"epss":{"probability":0.01736,"percentile":0.77345,"severity":"low","asOf":"2026-10-19T00:00:00.000Z","change":{"pp":0.021000000000000185,"baselineDate":"2026-09-19T00:00:00.000Z","baselineScore":0.01715},"history":[{"date":"2026-09-14T00:00:00.000Z","score":0.01907,"percentile":null},{"date":"2026-09-15T00:00:00.000Z","score":0.01907,"percentile":null},{"date":"2026-09-16T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-17T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-18T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.01736,"percentile":0.77345}],"last30":[{"date":"2026-09-19T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01715,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01736,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.01736,"percentile":0.77345}]},"kev":{"state":"not-listed","entries":[],"listedCount":0,"totalCatalogs":3,"catalogs":[{"source":"cisa","label":"CISA","listed":false,"entry":null},{"source":"enisa","label":"ENISA","listed":false,"entry":null},{"source":"circl","label":"CIRCL","listed":false,"entry":null}]},"ransomware":{"state":"none-recorded","sources":[]},"exploits":[],"exploitCount":0,"weaknesses":[{"id":"CWE-122","name":"Heap-based Buffer Overflow","description":"A heap overflow condition is a buffer overflow, where the buffer that can be overwritten is allocated in the heap portion of memory, generally meaning that the buffer was allocated using a routine such as malloc().","type":"weakness","status":"Draft","abstraction":"Variant","likelihoodOfExploit":"High","url":"https://cwe.mitre.org/data/definitions/122.html"},{"id":"CWE-787","name":"Out-of-bounds Write","description":"The product writes data past the end, or before the beginning, of the intended buffer.","type":"weakness","status":"Draft","abstraction":"Base","likelihoodOfExploit":"High","url":"https://cwe.mitre.org/data/definitions/787.html"}],"affected":[{"vendor":"siemens","product":"scalance x-200 switch family (incl. siplus net variants)","name":"SCALANCE X-200 switch family (incl. SIPLUS NET variants)","label":"scalance x-200 switch family (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_x-200_switch_family_incl_siplus_net_variants"},{"vendor":"siemens","product":"scalance x-200irt switch family (incl. siplus net variants)","name":"SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)","label":"scalance x-200irt switch family (incl. siplus net variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions < V5.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"All versions < V5.5.0","eol":null,"hubHref":"/vendor/siemens/scalance_x-200irt_switch_family_incl_siplus_net_variants"},{"vendor":"siemens","product":"scalance_x200-4pirt_firmware","name":"scalance x200-4pirt firmware","label":"scalance_x200-4pirt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.5.0","eol":null,"hubHref":"/vendor/siemens/scalance_x200-4pirt"},{"vendor":"siemens","product":"scalance_x201-3pirt_firmware","name":"scalance x201-3pirt firmware","label":"scalance_x201-3pirt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.5.0","eol":null,"hubHref":"/vendor/siemens/scalance_x201-3pirt"},{"vendor":"siemens","product":"scalance_x202-2irt_firmware","name":"scalance x202-2irt firmware","label":"scalance_x202-2irt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.5.0","eol":null,"hubHref":"/vendor/siemens/scalance_x202-2irt"},{"vendor":"siemens","product":"scalance_x202-2pirt_firmware","name":"scalance x202-2pirt firmware","label":"scalance_x202-2pirt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.5.0","eol":null,"hubHref":"/vendor/siemens/scalance_x202-2pirt"},{"vendor":"siemens","product":"scalance_x202-2pirt_siplus_net_firmware","name":"scalance x202-2pirt siplus net firmware","label":"scalance_x202-2pirt_siplus_net_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.5.0","eol":null,"hubHref":"/vendor/siemens/scalance_x202-2pirt_siplus_net"},{"vendor":"siemens","product":"scalance_x204irt_firmware","name":"scalance x204irt firmware","label":"scalance_x204irt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.5.0","eol":null,"hubHref":"/vendor/siemens/scalance_x204irt"},{"vendor":"siemens","product":"scalance_xb205-3_firmware","name":"scalance xb205-3 firmware","label":"scalance_xb205-3_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xb205-3"},{"vendor":"siemens","product":"scalance_xb205-3ld_firmware","name":"scalance xb205-3ld firmware","label":"scalance_xb205-3ld_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xb205-3ld"},{"vendor":"siemens","product":"scalance_xb208_firmware","name":"scalance xb208 firmware","label":"scalance_xb208_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xb208"},{"vendor":"siemens","product":"scalance_xb213-3_firmware","name":"scalance xb213-3 firmware","label":"scalance_xb213-3_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xb213-3"},{"vendor":"siemens","product":"scalance_xb213-3ld_firmware","name":"scalance xb213-3ld firmware","label":"scalance_xb213-3ld_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xb213-3ld"},{"vendor":"siemens","product":"scalance_xb216_firmware","name":"scalance xb216 firmware","label":"scalance_xb216_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xb216"},{"vendor":"siemens","product":"scalance_xc206-2_firmware","name":"scalance xc206-2 firmware","label":"scalance_xc206-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc206-2"},{"vendor":"siemens","product":"scalance_xc206-2g_poe__firmware","name":"scalance xc206-2g poe  firmware","label":"scalance_xc206-2g_poe__firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc206-2g_poe_"},{"vendor":"siemens","product":"scalance_xc206-2g_poe_eec_firmware","name":"scalance xc206-2g poe eec firmware","label":"scalance_xc206-2g_poe_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc206-2g_poe_eec"},{"vendor":"siemens","product":"scalance_xc206-2sfp_firmware","name":"scalance xc206-2sfp firmware","label":"scalance_xc206-2sfp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc206-2sfp"},{"vendor":"siemens","product":"scalance_xc206-2sfp_eec_firmware","name":"scalance xc206-2sfp eec firmware","label":"scalance_xc206-2sfp_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc206-2sfp_eec"},{"vendor":"siemens","product":"scalance_xc206-2sfp_g_firmware","name":"scalance xc206-2sfp g firmware","label":"scalance_xc206-2sfp_g_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc206-2sfp_g"},{"vendor":"siemens","product":"scalance_xc206-2sfp_g_eec_firmware","name":"scalance xc206-2sfp g eec firmware","label":"scalance_xc206-2sfp_g_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc206-2sfp_g_eec"},{"vendor":"siemens","product":"scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware","name":"scalance xc206-2sfp g \\(e\\/ip\\) firmware","label":"scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc206-2sfp_g_eip"},{"vendor":"siemens","product":"scalance_xc208_firmware","name":"scalance xc208 firmware","label":"scalance_xc208_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc208"},{"vendor":"siemens","product":"scalance_xc208eec_firmware","name":"scalance xc208eec firmware","label":"scalance_xc208eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc208eec"},{"vendor":"siemens","product":"scalance_xc208g_firmware","name":"scalance xc208g firmware","label":"scalance_xc208g_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc208g"},{"vendor":"siemens","product":"scalance_xc208g_eec_firmware","name":"scalance xc208g eec firmware","label":"scalance_xc208g_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc208g_eec"},{"vendor":"siemens","product":"scalance_xc208g_\\(e\\/ip\\)_firmware","name":"scalance xc208g \\(e\\/ip\\) firmware","label":"scalance_xc208g_\\(e\\/ip\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc208g_eip"},{"vendor":"siemens","product":"scalance_xc208g_poe_firmware","name":"scalance xc208g poe firmware","label":"scalance_xc208g_poe_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc208g_poe"},{"vendor":"siemens","product":"scalance_xc216_firmware","name":"scalance xc216 firmware","label":"scalance_xc216_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc216"},{"vendor":"siemens","product":"scalance_xc216-4c_firmware","name":"scalance xc216-4c firmware","label":"scalance_xc216-4c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc216-4c"},{"vendor":"siemens","product":"scalance_xc216-4c_g_firmware","name":"scalance xc216-4c g firmware","label":"scalance_xc216-4c_g_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc216-4c_g"},{"vendor":"siemens","product":"scalance_xc216-4c_g_eec_firmware","name":"scalance xc216-4c g eec firmware","label":"scalance_xc216-4c_g_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc216-4c_g_eec"},{"vendor":"siemens","product":"scalance_xc216-4c_g_\\(e\\/ip\\)_firmware","name":"scalance xc216-4c g \\(e\\/ip\\) firmware","label":"scalance_xc216-4c_g_\\(e\\/ip\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc216-4c_g_eip"},{"vendor":"siemens","product":"scalance_xc216eec_firmware","name":"scalance xc216eec firmware","label":"scalance_xc216eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc216eec"},{"vendor":"siemens","product":"scalance_xc224__firmware","name":"scalance xc224  firmware","label":"scalance_xc224__firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc224_"},{"vendor":"siemens","product":"scalance_xc224-4c_g__firmware","name":"scalance xc224-4c g  firmware","label":"scalance_xc224-4c_g__firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc224-4c_g_"},{"vendor":"siemens","product":"scalance_xc224-4c_g_eec_firmware","name":"scalance xc224-4c g eec firmware","label":"scalance_xc224-4c_g_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc224-4c_g_eec"},{"vendor":"siemens","product":"scalance_xc224-4c_g_\\(e\\/ip\\)_firmware","name":"scalance xc224-4c g \\(e\\/ip\\) firmware","label":"scalance_xc224-4c_g_\\(e\\/ip\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xc224-4c_g_eip"},{"vendor":"siemens","product":"scalance_xf201-3p_irt_firmware","name":"scalance xf201-3p irt firmware","label":"scalance_xf201-3p_irt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf201-3p_irt"},{"vendor":"siemens","product":"scalance_xf202-2p_irt_firmware","name":"scalance xf202-2p irt firmware","label":"scalance_xf202-2p_irt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf202-2p_irt"},{"vendor":"siemens","product":"scalance_xf204_firmware","name":"scalance xf204 firmware","label":"scalance_xf204_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf204"},{"vendor":"siemens","product":"scalance_xf204_dna_firmware","name":"scalance xf204 dna firmware","label":"scalance_xf204_dna_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf204_dna"},{"vendor":"siemens","product":"scalance_xf204-2_firmware","name":"scalance xf204-2 firmware","label":"scalance_xf204-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf204-2"},{"vendor":"siemens","product":"scalance_xf204-2ba_dna_firmware","name":"scalance xf204-2ba dna firmware","label":"scalance_xf204-2ba_dna_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf204-2ba_dna"},{"vendor":"siemens","product":"scalance_xf204-2ba_irt_firmware","name":"scalance xf204-2ba irt firmware","label":"scalance_xf204-2ba_irt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf204-2ba_irt"},{"vendor":"siemens","product":"scalance_xf204irt_firmware","name":"scalance xf204irt firmware","label":"scalance_xf204irt_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf204irt"},{"vendor":"siemens","product":"scalance_xf206-1_firmware","name":"scalance xf206-1 firmware","label":"scalance_xf206-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf206-1"},{"vendor":"siemens","product":"scalance_xf208_firmware","name":"scalance xf208 firmware","label":"scalance_xf208_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xf208"},{"vendor":"siemens","product":"scalance_xp208_firmware","name":"scalance xp208 firmware","label":"scalance_xp208_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xp208"},{"vendor":"siemens","product":"scalance_xp208_\\(eip\\)_firmware","name":"scalance xp208 \\(eip\\) firmware","label":"scalance_xp208_\\(eip\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xp208_eip"},{"vendor":"siemens","product":"scalance_xp208eec_firmware","name":"scalance xp208eec firmware","label":"scalance_xp208eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xp208eec"},{"vendor":"siemens","product":"scalance_xp208poe_eec_firmware","name":"scalance xp208poe eec firmware","label":"scalance_xp208poe_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xp208poe_eec"},{"vendor":"siemens","product":"scalance_xp216_firmware","name":"scalance xp216 firmware","label":"scalance_xp216_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xp216"},{"vendor":"siemens","product":"scalance_xp216_\\(eip\\)_firmware","name":"scalance xp216 \\(eip\\) firmware","label":"scalance_xp216_\\(eip\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xp216_eip"},{"vendor":"siemens","product":"scalance_xp216eec_firmware","name":"scalance xp216eec firmware","label":"scalance_xp216eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xp216eec"},{"vendor":"siemens","product":"scalance_xp216poe_eec_firmware","name":"scalance xp216poe eec firmware","label":"scalance_xp216poe_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< 5.2.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 5.2.5","eol":null,"hubHref":"/vendor/siemens/scalance_xp216poe_eec"}],"affectedCount":56,"eol":{"hasEol":false,"count":0},"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf","label":"cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf","hostname":"cert-portal.siemens.com","tags":["X Refsource MISC","Vendor Advisory"]}],"lineage":{"upstream":[],"downstream":[],"duplicates":[],"related":[]},"timeline":[{"kind":"published","date":"2021-01-12T20:18:33.000Z","label":"Published","detail":"Vulnerability first disclosed.","source":null},{"kind":"modified","date":"2024-08-04T15:33:04.885Z","label":"Last modified","detail":"Vulnerability information updated.","source":null}],"risk":{"score":70,"level":"high","profile":"Default","thresholds":{"critical":75,"high":50,"medium":25,"low":10}},"meta":{"dataAsOf":"2026-10-19T19:35:49.136Z","stale":false,"partial":false}}