{"schemaVersion":3,"id":"CVE-2022-47381","aliases":[],"status":"published","duplicateOf":null,"title":null,"description":"An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.","dates":{"published":"2023-05-15T09:41:51.613Z","modified":"2025-03-05T19:00:50.181Z","reserved":null,"kevAdded":[],"kevDue":[]},"cvss":{"headline":{"score":8.8,"severity":"high","version":"3.1","versionLabel":"v3.1","source":"CVE.org","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","computed":false,"selection":"backend-summary"},"metrics":[{"version":"3.1","versionLabel":"v3.1","source":"CVE.org","score":8.8,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"NVD","score":8.8,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","exploitability":null,"impact":null,"computed":false}]},"epss":{"probability":0.01323,"percentile":0.70475,"severity":"low","asOf":"2026-10-19T00:00:00.000Z","change":{"pp":0,"baselineDate":"2026-09-19T00:00:00.000Z","baselineScore":0.01323},"history":[{"date":"2026-09-14T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-15T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-16T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-17T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-18T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.01323,"percentile":0.70475}],"last30":[{"date":"2026-09-19T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.01323,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.01323,"percentile":0.70475}]},"kev":{"state":"not-listed","entries":[],"listedCount":0,"totalCatalogs":3,"catalogs":[{"source":"cisa","label":"CISA","listed":false,"entry":null},{"source":"enisa","label":"ENISA","listed":false,"entry":null},{"source":"circl","label":"CIRCL","listed":false,"entry":null}]},"ransomware":{"state":"none-recorded","sources":[]},"exploits":[],"exploitCount":0,"weaknesses":[{"id":"CWE-787","name":"Out-of-bounds Write","description":"The product writes data past the end, or before the beginning, of the intended buffer.","type":"weakness","status":"Draft","abstraction":"Base","likelihoodOfExploit":"High","url":"https://cwe.mitre.org/data/definitions/787.html"}],"affected":[{"vendor":"codesys","product":"codesys control for beaglebone sl","name":"CODESYS Control for BeagleBone SL","label":"codesys control for beaglebone sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_beaglebone_sl"},{"vendor":"codesys","product":"codesys control for empc-a/imx6 sl","name":"CODESYS Control for emPC-A/iMX6 SL","label":"codesys control for empc-a/imx6 sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_empc-aimx6_sl"},{"vendor":"codesys","product":"codesys control for iot2000 sl","name":"CODESYS Control for IOT2000 SL","label":"codesys control for iot2000 sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_iot2000_sl"},{"vendor":"codesys","product":"codesys control for linux sl","name":"CODESYS Control for Linux SL","label":"codesys control for linux sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_linux_sl"},{"vendor":"codesys","product":"codesys control for pfc100 sl","name":"CODESYS Control for PFC100 SL","label":"codesys control for pfc100 sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_pfc100_sl"},{"vendor":"codesys","product":"codesys control for pfc200 sl","name":"CODESYS Control for PFC200 SL","label":"codesys control for pfc200 sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_pfc200_sl"},{"vendor":"codesys","product":"codesys control for plcnext sl","name":"CODESYS Control for PLCnext SL","label":"codesys control for plcnext sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_plcnext_sl"},{"vendor":"codesys","product":"codesys control for raspberry pi sl","name":"CODESYS Control for Raspberry Pi SL","label":"codesys control for raspberry pi sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_raspberry_pi_sl"},{"vendor":"codesys","product":"codesys control for wago touch panels 600 sl","name":"CODESYS Control for WAGO Touch Panels 600 SL","label":"codesys control for wago touch panels 600 sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V4.8.0.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_for_wago_touch_panels_600_sl"},{"vendor":"codesys","product":"codesys control rte (for beckhoff cx) sl","name":"CODESYS Control RTE (for Beckhoff CX) SL","label":"codesys control rte (for beckhoff cx) sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V3.5.19.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_rte_for_beckhoff_cx_sl"},{"vendor":"codesys","product":"codesys control rte (sl)","name":"CODESYS Control RTE (SL)","label":"codesys control rte (sl)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V3.5.19.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_rte_sl"},{"vendor":"codesys","product":"codesys control runtime system toolkit","name":"CODESYS Control Runtime System Toolkit","label":"codesys control runtime system toolkit","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V3.5.19.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_runtime_system_toolkit"},{"vendor":"codesys","product":"codesys control win (sl)","name":"CODESYS Control Win (SL)","label":"codesys control win (sl)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V3.5.19.0","eol":null,"hubHref":"/vendor/codesys/codesys_control_win_sl"},{"vendor":"codesys","product":"codesys development system v3","name":"CODESYS Development System V3","label":"codesys development system v3","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V3.5.19.0","eol":null,"hubHref":"/vendor/codesys/codesys_development_system_v3"},{"vendor":"codesys","product":"codesys hmi (sl)","name":"CODESYS HMI (SL)","label":"codesys hmi (sl)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V3.5.19.0","eol":null,"hubHref":"/vendor/codesys/codesys_hmi_sl"},{"vendor":"codesys","product":"codesys safety sil2 psp","name":"CODESYS Safety SIL2 PSP","label":"codesys safety sil2 psp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V3.5.19.0","eol":null,"hubHref":"/vendor/codesys/codesys_safety_sil2_psp"},{"vendor":"codesys","product":"codesys safety sil2 runtime toolkit","name":"CODESYS Safety SIL2 Runtime Toolkit","label":"codesys safety sil2 runtime toolkit","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"≥ V0.0.0.0, < V3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"≥ V0.0.0.0, < V3.5.19.0","eol":null,"hubHref":"/vendor/codesys/codesys_safety_sil2_runtime_toolkit"},{"vendor":"codesys","product":"control_for_beaglebone_sl","name":"control for beaglebone sl","label":"control_for_beaglebone_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_beaglebone_sl"},{"vendor":"codesys","product":"control_for_empc-a\\/imx6_sl","name":"control for empc-a\\/imx6 sl","label":"control_for_empc-a\\/imx6_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_empc-aimx6_sl"},{"vendor":"codesys","product":"control_for_iot2000_sl","name":"control for iot2000 sl","label":"control_for_iot2000_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_iot2000_sl"},{"vendor":"codesys","product":"control_for_linux_sl","name":"control for linux sl","label":"control_for_linux_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_linux_sl"},{"vendor":"codesys","product":"control_for_pfc100_sl","name":"control for pfc100 sl","label":"control_for_pfc100_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_pfc100_sl"},{"vendor":"codesys","product":"control_for_pfc200_sl","name":"control for pfc200 sl","label":"control_for_pfc200_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_pfc200_sl"},{"vendor":"codesys","product":"control_for_plcnext_sl","name":"control for plcnext sl","label":"control_for_plcnext_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_plcnext_sl"},{"vendor":"codesys","product":"control_for_raspberry_pi_sl","name":"control for raspberry pi sl","label":"control_for_raspberry_pi_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_raspberry_pi_sl"},{"vendor":"codesys","product":"control_for_wago_touch_panels_600_sl","name":"control for wago touch panels 600 sl","label":"control_for_wago_touch_panels_600_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 4.8.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 4.8.0.0","eol":null,"hubHref":"/vendor/codesys/control_for_wago_touch_panels_600_sl"},{"vendor":"codesys","product":"control_rte_\\(for_beckhoff_cx\\)_sl","name":"control rte \\(for beckhoff cx\\) sl","label":"control_rte_\\(for_beckhoff_cx\\)_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.5.19.0","eol":null,"hubHref":"/vendor/codesys/control_rte_for_beckhoff_cx_sl"},{"vendor":"codesys","product":"control_rte_sl","name":"control rte sl","label":"control_rte_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.5.19.0","eol":null,"hubHref":"/vendor/codesys/control_rte_sl"},{"vendor":"codesys","product":"control_runtime_system_toolkit","name":"control runtime system toolkit","label":"control_runtime_system_toolkit","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.5.19.0","eol":null,"hubHref":"/vendor/codesys/control_runtime_system_toolkit"},{"vendor":"codesys","product":"control_win_sl","name":"control win sl","label":"control_win_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.5.19.0","eol":null,"hubHref":"/vendor/codesys/control_win_sl"},{"vendor":"codesys","product":"development_system_v3","name":"development system v3","label":"development_system_v3","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.5.19.0","eol":null,"hubHref":"/vendor/codesys/development_system_v3"},{"vendor":"codesys","product":"hmi_sl","name":"hmi sl","label":"hmi_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.5.19.0","eol":null,"hubHref":"/vendor/codesys/hmi_sl"},{"vendor":"codesys","product":"safety_sil2_psp","name":"safety sil2 psp","label":"safety_sil2_psp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.5.19.0","eol":null,"hubHref":"/vendor/codesys/safety_sil2_psp"},{"vendor":"codesys","product":"safety_sil2_runtime_toolkit","name":"safety sil2 runtime toolkit","label":"safety_sil2_runtime_toolkit","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< 3.5.19.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< 3.5.19.0","eol":null,"hubHref":"/vendor/codesys/safety_sil2_runtime_toolkit"}],"affectedCount":34,"eol":{"hasEol":false,"count":0},"references":[{"url":"https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17554&token=5444f53b4c90fe37043671a100dffa75305d1825&download=","label":"customers.codesys.com/index.php","hostname":"customers.codesys.com","tags":["Vendor Advisory"]}],"lineage":{"upstream":[],"downstream":[],"duplicates":[],"related":[]},"timeline":[{"kind":"published","date":"2023-05-15T09:41:51.613Z","label":"Published","detail":"Vulnerability first disclosed.","source":null},{"kind":"modified","date":"2025-03-05T19:00:50.181Z","label":"Last modified","detail":"Vulnerability information updated.","source":null}],"risk":{"score":35,"level":"medium","profile":"Default","thresholds":{"critical":75,"high":50,"medium":25,"low":10}},"meta":{"dataAsOf":"2026-10-20T06:46:06.358Z","stale":false,"partial":false}}