{"schemaVersion":3,"id":"CVE-2025-30033","aliases":[],"status":"published","duplicateOf":null,"title":null,"description":"The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.","dates":{"published":"2025-08-12T11:16:56.565Z","modified":"2026-10-13T09:18:18.488Z","reserved":null,"kevAdded":[],"kevDue":[]},"cvss":{"headline":{"score":8.5,"severity":"high","version":"4.0","versionLabel":"v4.0","source":"CVE.org","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","computed":false,"selection":"backend-summary"},"metrics":[{"version":"4.0","versionLabel":"v4.0","source":"CVE.org","score":8.5,"severity":"high","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"CVE.org","score":7.8,"severity":"high","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","exploitability":null,"impact":null,"computed":false},{"version":"4.0","versionLabel":"v4.0","source":"NVD","score":8.5,"severity":"high","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"NVD","score":7.8,"severity":"high","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","exploitability":null,"impact":null,"computed":false}]},"epss":{"probability":0.00207,"percentile":0.10138,"severity":"low","asOf":"2026-10-18T00:00:00.000Z","change":{"pp":0.0009999999999999593,"baselineDate":"2026-09-18T00:00:00.000Z","baselineScore":0.00206},"history":[{"date":"2026-09-14T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-15T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-16T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-17T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-18T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.00207,"percentile":0.10138}],"last30":[{"date":"2026-09-18T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.00206,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.00207,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.00207,"percentile":0.10138}]},"kev":{"state":"not-listed","entries":[],"listedCount":0,"totalCatalogs":3,"catalogs":[{"source":"cisa","label":"CISA","listed":false,"entry":null},{"source":"enisa","label":"ENISA","listed":false,"entry":null},{"source":"circl","label":"CIRCL","listed":false,"entry":null}]},"ransomware":{"state":"none-recorded","sources":[]},"exploits":[],"exploitCount":0,"weaknesses":[{"id":"CWE-427","name":"Uncontrolled Search Path Element","description":"The product uses a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors.","type":"weakness","status":"Draft","abstraction":"Base","likelihoodOfExploit":null,"url":"https://cwe.mitre.org/data/definitions/427.html"}],"affected":[{"vendor":"siemens","product":"automation license manager v6.0","name":"Automation License Manager V6.0","label":"automation license manager v6.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/automation_license_manager_v60"},{"vendor":"siemens","product":"automation license manager v6.2","name":"Automation License Manager V6.2","label":"automation license manager v6.2","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.2 Upd3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.2 Upd3","eol":null,"hubHref":"/vendor/siemens/automation_license_manager_v62"},{"vendor":"siemens","product":"cemat v10.0","name":"CEMAT V10.0","label":"cemat v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/cemat_v100"},{"vendor":"siemens","product":"cp ptp param configuring interface","name":"CP PtP Param configuring interface","label":"cp ptp param configuring interface","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/cp_ptp_param_configuring_interface"},{"vendor":"siemens","product":"create myconfig (cmc)","name":"Create MyConfig (CMC)","label":"create myconfig (cmc)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.9","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.9","eol":null,"hubHref":"/vendor/siemens/create_myconfig_cmc"},{"vendor":"siemens","product":"energy support library (ensl)","name":"Energy Support Library (EnSL)","label":"energy support library (ensl)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/energy_support_library_ensl"},{"vendor":"siemens","product":"fm configuration package","name":"FM Configuration Package","label":"fm configuration package","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/fm_configuration_package"},{"vendor":"siemens","product":"modular pid ctrl tool","name":"Modular PID CTRL Tool","label":"modular pid ctrl tool","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/modular_pid_ctrl_tool"},{"vendor":"siemens","product":"multifieldbus configuration tool (mfct)","name":"MultiFieldbus Configuration Tool (MFCT)","label":"multifieldbus configuration tool (mfct)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V1.5.5.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V1.5.5.0","eol":null,"hubHref":"/vendor/siemens/multifieldbus_configuration_tool_mfct"},{"vendor":"siemens","product":"openpcs 7 v10.0","name":"OpenPCS 7 V10.0","label":"openpcs 7 v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/openpcs_7_v100"},{"vendor":"siemens","product":"openpcs 7 v9.1","name":"OpenPCS 7 V9.1","label":"openpcs 7 v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/openpcs_7_v91"},{"vendor":"siemens","product":"siemens network planner (sinetplan)","name":"Siemens Network Planner (SINETPLAN)","label":"siemens network planner (sinetplan)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V2.0 SP2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.0 SP2","eol":null,"hubHref":"/vendor/siemens/siemens_network_planner_sinetplan"},{"vendor":"siemens","product":"simatic automation tool","name":"SIMATIC Automation Tool","label":"simatic automation tool","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V5.0 SP4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V5.0 SP4","eol":null,"hubHref":"/vendor/siemens/simatic_automation_tool"},{"vendor":"siemens","product":"simatic automation tool sdk windows","name":"SIMATIC Automation Tool SDK Windows","label":"simatic automation tool sdk windows","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V5.0 SP4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V5.0 SP4","eol":null,"hubHref":"/vendor/siemens/simatic_automation_tool_sdk_windows"},{"vendor":"siemens","product":"simatic batch v10.0","name":"SIMATIC BATCH V10.0","label":"simatic batch v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_batch_v100"},{"vendor":"siemens","product":"simatic batch v9.1","name":"SIMATIC BATCH V9.1","label":"simatic batch v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_batch_v91"},{"vendor":"siemens","product":"simatic control function library (cfl) v1.x","name":"SIMATIC Control Function Library (CFL) V1.x","label":"simatic control function library (cfl) v1.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_control_function_library_cfl_v1x"},{"vendor":"siemens","product":"simatic control function library (cfl) v2.x","name":"SIMATIC Control Function Library (CFL) V2.x","label":"simatic control function library (cfl) v2.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_control_function_library_cfl_v2x"},{"vendor":"siemens","product":"simatic control function library (cfl) v3.x","name":"SIMATIC Control Function Library (CFL) V3.x","label":"simatic control function library (cfl) v3.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.1.0.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.1.0.2","eol":null,"hubHref":"/vendor/siemens/simatic_control_function_library_cfl_v3x"},{"vendor":"siemens","product":"simatic control function library (cfl) v4.x","name":"SIMATIC Control Function Library (CFL) V4.x","label":"simatic control function library (cfl) v4.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1","eol":null,"hubHref":"/vendor/siemens/simatic_control_function_library_cfl_v4x"},{"vendor":"siemens","product":"simatic d7-sys","name":"SIMATIC D7-SYS","label":"simatic d7-sys","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V10.0 SP1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V10.0 SP1","eol":null,"hubHref":"/vendor/siemens/simatic_d7-sys"},{"vendor":"siemens","product":"simatic easie core package","name":"SIMATIC eaSie Core Package","label":"simatic easie core package","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_easie_core_package"},{"vendor":"siemens","product":"simatic easie document skills","name":"SIMATIC eaSie Document Skills","label":"simatic easie document skills","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_easie_document_skills"},{"vendor":"siemens","product":"simatic easie pcs 7 skill package","name":"SIMATIC eaSie PCS 7 Skill Package","label":"simatic easie pcs 7 skill package","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_easie_pcs_7_skill_package"},{"vendor":"siemens","product":"simatic easie workflow skills","name":"SIMATIC eaSie Workflow Skills","label":"simatic easie workflow skills","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_easie_workflow_skills"},{"vendor":"siemens","product":"simatic energy suite v17","name":"SIMATIC Energy Suite V17","label":"simatic energy suite v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_energy_suite_v17"},{"vendor":"siemens","product":"simatic energy suite v18","name":"SIMATIC Energy Suite V18","label":"simatic energy suite v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_energy_suite_v18"},{"vendor":"siemens","product":"simatic energy suite v19","name":"SIMATIC Energy Suite V19","label":"simatic energy suite v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V19 Update 4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V19 Update 4","eol":null,"hubHref":"/vendor/siemens/simatic_energy_suite_v19"},{"vendor":"siemens","product":"simatic logon v1.6","name":"SIMATIC Logon V1.6","label":"simatic logon v1.6","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_logon_v16"},{"vendor":"siemens","product":"simatic logon v2.0","name":"SIMATIC Logon V2.0","label":"simatic logon v2.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V2.0 Upd3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.0 Upd3","eol":null,"hubHref":"/vendor/siemens/simatic_logon_v20"},{"vendor":"siemens","product":"simatic management agent","name":"SIMATIC Management Agent","label":"simatic management agent","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.1 SP1 Upd8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.1 SP1 Upd8","eol":null,"hubHref":"/vendor/siemens/simatic_management_agent"},{"vendor":"siemens","product":"simatic management console","name":"SIMATIC Management Console","label":"simatic management console","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.1 SP1 Upd8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.1 SP1 Upd8","eol":null,"hubHref":"/vendor/siemens/simatic_management_console"},{"vendor":"siemens","product":"simatic mtp creator v2.x","name":"SIMATIC MTP CREATOR V2.x","label":"simatic mtp creator v2.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V2.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.1","eol":null,"hubHref":"/vendor/siemens/simatic_mtp_creator_v2x"},{"vendor":"siemens","product":"simatic mtp creator v3.x","name":"SIMATIC MTP CREATOR V3.x","label":"simatic mtp creator v3.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_mtp_creator_v3x"},{"vendor":"siemens","product":"simatic mtp creator v4.x","name":"SIMATIC MTP CREATOR V4.x","label":"simatic mtp creator v4.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.0.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.0.1","eol":null,"hubHref":"/vendor/siemens/simatic_mtp_creator_v4x"},{"vendor":"siemens","product":"simatic mtp creator v5.x","name":"SIMATIC MTP CREATOR V5.x","label":"simatic mtp creator v5.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V5.0.0.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V5.0.0.1","eol":null,"hubHref":"/vendor/siemens/simatic_mtp_creator_v5x"},{"vendor":"siemens","product":"simatic mtp integrator v1.x","name":"SIMATIC MTP Integrator V1.x","label":"simatic mtp integrator v1.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_mtp_integrator_v1x"},{"vendor":"siemens","product":"simatic mtp integrator v2.x","name":"SIMATIC MTP Integrator V2.x","label":"simatic mtp integrator v2.x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_mtp_integrator_v2x"},{"vendor":"siemens","product":"simatic net pc software v16","name":"SIMATIC NET PC Software V16","label":"simatic net pc software v16","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_net_pc_software_v16"},{"vendor":"siemens","product":"simatic net pc software v17","name":"SIMATIC NET PC Software V17","label":"simatic net pc software v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_net_pc_software_v17"},{"vendor":"siemens","product":"simatic net pc software v18","name":"SIMATIC NET PC Software V18","label":"simatic net pc software v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_net_pc_software_v18"},{"vendor":"siemens","product":"simatic net pc software v19","name":"SIMATIC NET PC Software V19","label":"simatic net pc software v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_net_pc_software_v19"},{"vendor":"siemens","product":"simatic net pc software v20","name":"SIMATIC NET PC Software V20","label":"simatic net pc software v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V20.0 Update 1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V20.0 Update 1","eol":null,"hubHref":"/vendor/siemens/simatic_net_pc_software_v20"},{"vendor":"siemens","product":"simatic odk 1500s","name":"SIMATIC ODK 1500S","label":"simatic odk 1500s","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_odk_1500s"},{"vendor":"siemens","product":"simatic pcs 7 advanced process faceplates v9.1","name":"SIMATIC PCS 7 Advanced Process Faceplates V9.1","label":"simatic pcs 7 advanced process faceplates v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.1 SP2 Upd4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.1 SP2 Upd4","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_advanced_process_faceplates_v91"},{"vendor":"siemens","product":"simatic pcs 7 advanced process functions v2.1","name":"SIMATIC PCS 7 Advanced Process Functions V2.1","label":"simatic pcs 7 advanced process functions v2.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_advanced_process_functions_v21"},{"vendor":"siemens","product":"simatic pcs 7 advanced process functions v2.2","name":"SIMATIC PCS 7 Advanced Process Functions V2.2","label":"simatic pcs 7 advanced process functions v2.2","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_advanced_process_functions_v22"},{"vendor":"siemens","product":"simatic pcs 7 advanced process graphics v10.0","name":"SIMATIC PCS 7 Advanced Process Graphics V10.0","label":"simatic pcs 7 advanced process graphics v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_advanced_process_graphics_v100"},{"vendor":"siemens","product":"simatic pcs 7 advanced process graphics v9.1","name":"SIMATIC PCS 7 Advanced Process Graphics V9.1","label":"simatic pcs 7 advanced process graphics v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_advanced_process_graphics_v91"},{"vendor":"siemens","product":"simatic pcs 7 advanced process library incl. faceplates v10.0","name":"SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0","label":"simatic pcs 7 advanced process library incl. faceplates v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_advanced_process_library_incl_faceplates_v100"},{"vendor":"siemens","product":"simatic pcs 7 advanced process library v9.1","name":"SIMATIC PCS 7 Advanced Process Library V9.1","label":"simatic pcs 7 advanced process library v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.1 SP2 Upd6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.1 SP2 Upd6","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_advanced_process_library_v91"},{"vendor":"siemens","product":"simatic pcs 7 basis faceplates v9.1","name":"SIMATIC PCS 7 Basis Faceplates V9.1","label":"simatic pcs 7 basis faceplates v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.1 SP2 Upd2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.1 SP2 Upd2","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_basis_faceplates_v91"},{"vendor":"siemens","product":"simatic pcs 7 basis library v10.0","name":"SIMATIC PCS 7 Basis Library V10.0","label":"simatic pcs 7 basis library v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V10.0 SP1 Upd2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V10.0 SP1 Upd2","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_basis_library_v100"},{"vendor":"siemens","product":"simatic pcs 7 basis library v9.1","name":"SIMATIC PCS 7 Basis Library V9.1","label":"simatic pcs 7 basis library v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.1 SP2 Upd8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.1 SP2 Upd8","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_basis_library_v91"},{"vendor":"siemens","product":"simatic pcs 7 industry library v10.0","name":"SIMATIC PCS 7 Industry Library V10.0","label":"simatic pcs 7 industry library v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_industry_library_v100"},{"vendor":"siemens","product":"simatic pcs 7 industry library v9.0","name":"SIMATIC PCS 7 Industry Library V9.0","label":"simatic pcs 7 industry library v9.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_industry_library_v90"},{"vendor":"siemens","product":"simatic pcs 7 industry library v9.1","name":"SIMATIC PCS 7 Industry Library V9.1","label":"simatic pcs 7 industry library v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_industry_library_v91"},{"vendor":"siemens","product":"simatic pcs 7 logic matrix v10.0","name":"SIMATIC PCS 7 Logic Matrix V10.0","label":"simatic pcs 7 logic matrix v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_logic_matrix_v100"},{"vendor":"siemens","product":"simatic pcs 7 logic matrix v9.1","name":"SIMATIC PCS 7 Logic Matrix V9.1","label":"simatic pcs 7 logic matrix v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.1 Upd8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.1 Upd8","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_logic_matrix_v91"},{"vendor":"siemens","product":"simatic pcs 7 mpc configurator","name":"SIMATIC PCS 7 MPC Configurator","label":"simatic pcs 7 mpc configurator","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_mpc_configurator"},{"vendor":"siemens","product":"simatic pcs 7 powercontrol v9.1","name":"SIMATIC PCS 7 PowerControl V9.1","label":"simatic pcs 7 powercontrol v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_powercontrol_v91"},{"vendor":"siemens","product":"simatic pcs 7 standard chemical library v10.0","name":"SIMATIC PCS 7 Standard Chemical Library V10.0","label":"simatic pcs 7 standard chemical library v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_standard_chemical_library_v100"},{"vendor":"siemens","product":"simatic pcs 7 standard chemical library v9.1","name":"SIMATIC PCS 7 Standard Chemical Library V9.1","label":"simatic pcs 7 standard chemical library v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_standard_chemical_library_v91"},{"vendor":"siemens","product":"simatic pcs 7 telecontrol v9.1","name":"SIMATIC PCS 7 TeleControl V9.1","label":"simatic pcs 7 telecontrol v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_telecontrol_v91"},{"vendor":"siemens","product":"simatic pcs 7 v10.0","name":"SIMATIC PCS 7 V10.0","label":"simatic pcs 7 v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V10.0 SP1 UC01","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V10.0 SP1 UC01","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_v100"},{"vendor":"siemens","product":"simatic pcs 7 v9.1","name":"SIMATIC PCS 7 V9.1","label":"simatic pcs 7 v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.1 SP1 UC08","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.1 SP1 UC08","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7_v91"},{"vendor":"siemens","product":"simatic pcs 7/open os v9.1","name":"SIMATIC PCS 7/OPEN OS V9.1","label":"simatic pcs 7/open os v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_7open_os_v91"},{"vendor":"siemens","product":"simatic pcs neo v5.0","name":"SIMATIC PCS neo V5.0","label":"simatic pcs neo v5.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_neo_v50"},{"vendor":"siemens","product":"simatic pcs neo v6.0","name":"SIMATIC PCS neo V6.0","label":"simatic pcs neo v6.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.0 SP1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.0 SP1","eol":null,"hubHref":"/vendor/siemens/simatic_pcs_neo_v60"},{"vendor":"siemens","product":"simatic pdm maintenance station v5.0","name":"SIMATIC PDM Maintenance Station V5.0","label":"simatic pdm maintenance station v5.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pdm_maintenance_station_v50"},{"vendor":"siemens","product":"simatic pdm v9.2","name":"SIMATIC PDM V9.2","label":"simatic pdm v9.2","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_pdm_v92"},{"vendor":"siemens","product":"simatic pdm v9.3","name":"SIMATIC PDM V9.3","label":"simatic pdm v9.3","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V9.3 SP1 Upd2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V9.3 SP1 Upd2","eol":null,"hubHref":"/vendor/siemens/simatic_pdm_v93"},{"vendor":"siemens","product":"simatic process function library (pfl) v4.0","name":"SIMATIC Process Function Library (PFL) V4.0","label":"simatic process function library (pfl) v4.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_process_function_library_pfl_v40"},{"vendor":"siemens","product":"simatic process historian 2020","name":"SIMATIC Process Historian 2020","label":"simatic process historian 2020","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_process_historian_2020"},{"vendor":"siemens","product":"simatic process historian 2022","name":"SIMATIC Process Historian 2022","label":"simatic process historian 2022","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_process_historian_2022"},{"vendor":"siemens","product":"simatic process historian 2024","name":"SIMATIC Process Historian 2024","label":"simatic process historian 2024","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V2024 SP1 Upd2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2024 SP1 Upd2","eol":null,"hubHref":"/vendor/siemens/simatic_process_historian_2024"},{"vendor":"siemens","product":"simatic prosave v17","name":"SIMATIC ProSave V17","label":"simatic prosave v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V17 Update 9","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V17 Update 9","eol":null,"hubHref":"/vendor/siemens/simatic_prosave_v17"},{"vendor":"siemens","product":"simatic prosave v18","name":"SIMATIC ProSave V18","label":"simatic prosave v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_prosave_v18"},{"vendor":"siemens","product":"simatic prosave v19","name":"SIMATIC ProSave V19","label":"simatic prosave v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V19 Update 4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V19 Update 4","eol":null,"hubHref":"/vendor/siemens/simatic_prosave_v19"},{"vendor":"siemens","product":"simatic prosave v20","name":"SIMATIC ProSave V20","label":"simatic prosave v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_prosave_v20"},{"vendor":"siemens","product":"simatic route control v10.0","name":"SIMATIC Route Control V10.0","label":"simatic route control v10.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_route_control_v100"},{"vendor":"siemens","product":"simatic route control v9.1","name":"SIMATIC Route Control V9.1","label":"simatic route control v9.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_route_control_v91"},{"vendor":"siemens","product":"simatic s7 f systems v6.3","name":"SIMATIC S7 F Systems V6.3","label":"simatic s7 f systems v6.3","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7_f_systems_v63"},{"vendor":"siemens","product":"simatic s7 f systems v6.4","name":"SIMATIC S7 F Systems V6.4","label":"simatic s7 f systems v6.4","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7_f_systems_v64"},{"vendor":"siemens","product":"simatic s7-1500 software controller v2","name":"SIMATIC S7-1500 Software Controller V2","label":"simatic s7-1500 software controller v2","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_software_controller_v2"},{"vendor":"siemens","product":"simatic s7-1500 software controller v3","name":"SIMATIC S7-1500 Software Controller V3","label":"simatic s7-1500 software controller v3","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V31.1.5","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V31.1.5","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_software_controller_v3"},{"vendor":"siemens","product":"simatic s7-fail-safe configuration tool (s7-fct)","name":"SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)","label":"simatic s7-fail-safe configuration tool (s7-fct)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.0.1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.0.1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-fail-safe_configuration_tool_s7-fct"},{"vendor":"siemens","product":"simatic s7-pct","name":"SIMATIC S7-PCT","label":"simatic s7-pct","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.5 SP4 Update 1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.5 SP4 Update 1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-pct"},{"vendor":"siemens","product":"simatic s7-plcsim advanced","name":"SIMATIC S7-PLCSIM Advanced","label":"simatic s7-plcsim advanced","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.0 Update 1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.0 Update 1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-plcsim_advanced"},{"vendor":"siemens","product":"simatic s7-plcsim v17","name":"SIMATIC S7-PLCSIM V17","label":"simatic s7-plcsim v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-plcsim_v17"},{"vendor":"siemens","product":"simatic s7-plcsim v18","name":"SIMATIC S7-PLCSIM V18","label":"simatic s7-plcsim v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-plcsim_v18"},{"vendor":"siemens","product":"simatic s7-plcsim v19","name":"SIMATIC S7-PLCSIM V19","label":"simatic s7-plcsim v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-plcsim_v19"},{"vendor":"siemens","product":"simatic s7-plcsim v20","name":"SIMATIC S7-PLCSIM V20","label":"simatic s7-plcsim v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V20 Update 1","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V20 Update 1","eol":null,"hubHref":"/vendor/siemens/simatic_s7-plcsim_v20"},{"vendor":"siemens","product":"simatic safety matrix v6.3","name":"SIMATIC Safety Matrix V6.3","label":"simatic safety matrix v6.3","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_safety_matrix_v63"},{"vendor":"siemens","product":"simatic step 7 cfc v19","name":"SIMATIC STEP 7 CFC V19","label":"simatic step 7 cfc v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_step_7_cfc_v19"},{"vendor":"siemens","product":"simatic step 7 cfc v20","name":"SIMATIC STEP 7 CFC V20","label":"simatic step 7 cfc v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_step_7_cfc_v20"},{"vendor":"siemens","product":"simatic step 7 v5.7","name":"SIMATIC STEP 7 V5.7","label":"simatic step 7 v5.7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_step_7_v57"},{"vendor":"siemens","product":"simatic target","name":"SIMATIC Target","label":"simatic target","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.0 SP3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.0 SP3","eol":null,"hubHref":"/vendor/siemens/simatic_target"},{"vendor":"siemens","product":"simatic wincc flexible es","name":"SIMATIC WinCC flexible ES","label":"simatic wincc flexible es","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_flexible_es"},{"vendor":"siemens","product":"simatic wincc runtime advanced","name":"SIMATIC WinCC Runtime Advanced","label":"simatic wincc runtime advanced","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V17 Update 9","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V17 Update 9","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_runtime_advanced"},{"vendor":"siemens","product":"simatic wincc runtime professional","name":"SIMATIC WinCC Runtime Professional","label":"simatic wincc runtime professional","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V21","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V21","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_runtime_professional"},{"vendor":"siemens","product":"simatic wincc runtime professional v20","name":"SIMATIC WinCC Runtime Professional V20","label":"simatic wincc runtime professional v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_runtime_professional_v20"},{"vendor":"siemens","product":"simatic wincc telecontrol","name":"SIMATIC WinCC TeleControl","label":"simatic wincc telecontrol","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_telecontrol"},{"vendor":"siemens","product":"simatic wincc unified line coordination","name":"SIMATIC WinCC Unified Line Coordination","label":"simatic wincc unified line coordination","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V20","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V20","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_unified_line_coordination"},{"vendor":"siemens","product":"simatic wincc unified pc runtime v18","name":"SIMATIC WinCC Unified PC Runtime V18","label":"simatic wincc unified pc runtime v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_unified_pc_runtime_v18"},{"vendor":"siemens","product":"simatic wincc unified pc runtime v19","name":"SIMATIC WinCC Unified PC Runtime V19","label":"simatic wincc unified pc runtime v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_unified_pc_runtime_v19"},{"vendor":"siemens","product":"simatic wincc unified pc runtime v20","name":"SIMATIC WinCC Unified PC Runtime V20","label":"simatic wincc unified pc runtime v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_unified_pc_runtime_v20"},{"vendor":"siemens","product":"simatic wincc unified sequence","name":"SIMATIC WinCC Unified Sequence","label":"simatic wincc unified sequence","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V20","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V20","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_unified_sequence"},{"vendor":"siemens","product":"simatic wincc v7.5","name":"SIMATIC WinCC V7.5","label":"simatic wincc v7.5","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V7.5 SP2 Update 20","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V7.5 SP2 Update 20","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_v75"},{"vendor":"siemens","product":"simatic wincc v8.0","name":"SIMATIC WinCC V8.0","label":"simatic wincc v8.0","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V8.0 Update 8","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.0 Update 8","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_v80"},{"vendor":"siemens","product":"simatic wincc v8.1","name":"SIMATIC WinCC V8.1","label":"simatic wincc v8.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V8.1 Update 3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.1 Update 3","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_v81"},{"vendor":"siemens","product":"simatic wincc visualization architect (sivarc) v17","name":"SIMATIC WinCC Visualization Architect (SiVArc) V17","label":"simatic wincc visualization architect (sivarc) v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V17 Update 9","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V17 Update 9","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_visualization_architect_sivarc_v17"},{"vendor":"siemens","product":"simatic wincc visualization architect (sivarc) v18","name":"SIMATIC WinCC Visualization Architect (SiVArc) V18","label":"simatic wincc visualization architect (sivarc) v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_visualization_architect_sivarc_v18"},{"vendor":"siemens","product":"simatic wincc visualization architect (sivarc) v19","name":"SIMATIC WinCC Visualization Architect (SiVArc) V19","label":"simatic wincc visualization architect (sivarc) v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V19 Update 4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V19 Update 4","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_visualization_architect_sivarc_v19"},{"vendor":"siemens","product":"simatic wincc visualization architect (sivarc) v20","name":"SIMATIC WinCC Visualization Architect (SiVArc) V20","label":"simatic wincc visualization architect (sivarc) v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V20 Update 3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V20 Update 3","eol":null,"hubHref":"/vendor/siemens/simatic_wincc_visualization_architect_sivarc_v20"},{"vendor":"siemens","product":"simit rapid tester","name":"SIMIT Rapid Tester","label":"simit rapid tester","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simit_rapid_tester"},{"vendor":"siemens","product":"simit simulation platform","name":"SIMIT Simulation Platform","label":"simit simulation platform","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simit_simulation_platform"},{"vendor":"siemens","product":"sinamics startdrive v17","name":"SINAMICS Startdrive V17","label":"sinamics startdrive v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_startdrive_v17"},{"vendor":"siemens","product":"sinamics startdrive v18","name":"SINAMICS Startdrive V18","label":"sinamics startdrive v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_startdrive_v18"},{"vendor":"siemens","product":"sinamics startdrive v19","name":"SINAMICS Startdrive V19","label":"sinamics startdrive v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_startdrive_v19"},{"vendor":"siemens","product":"sinamics startdrive v20","name":"SINAMICS Startdrive V20","label":"sinamics startdrive v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_startdrive_v20"},{"vendor":"siemens","product":"sinec nms","name":"SINEC NMS","label":"sinec nms","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.0","eol":null,"hubHref":"/vendor/siemens/sinec_nms"},{"vendor":"siemens","product":"sinema remote connect client","name":"SINEMA Remote Connect Client","label":"sinema remote connect client","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinema_remote_connect_client"},{"vendor":"siemens","product":"sitrans","name":"SITRANS","label":"sitrans","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitrans"},{"vendor":"siemens","product":"standard pid ctrl tool","name":"Standard PID CTRL Tool","label":"standard pid ctrl tool","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/standard_pid_ctrl_tool"},{"vendor":"siemens","product":"telecontrol server basic v3.1","name":"TeleControl Server Basic V3.1","label":"telecontrol server basic v3.1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.1.2.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.1.2.2","eol":null,"hubHref":"/vendor/siemens/telecontrol_server_basic_v31"},{"vendor":"siemens","product":"tia administrator","name":"TIA Administrator","label":"tia administrator","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.0.6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.0.6","eol":null,"hubHref":"/vendor/siemens/tia_administrator"},{"vendor":"siemens","product":"tia portal cloud connector","name":"TIA Portal Cloud Connector","label":"tia portal cloud connector","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V2.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.3","eol":null,"hubHref":"/vendor/siemens/tia_portal_cloud_connector"},{"vendor":"siemens","product":"tia portal test suite v17","name":"TIA Portal Test Suite V17","label":"tia portal test suite v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/tia_portal_test_suite_v17"},{"vendor":"siemens","product":"tia portal test suite v18","name":"TIA Portal Test Suite V18","label":"tia portal test suite v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/tia_portal_test_suite_v18"},{"vendor":"siemens","product":"tia portal test suite v19","name":"TIA Portal Test Suite V19","label":"tia portal test suite v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V19 Update 4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V19 Update 4","eol":null,"hubHref":"/vendor/siemens/tia_portal_test_suite_v19"},{"vendor":"siemens","product":"tia portal test suite v20","name":"TIA Portal Test Suite V20","label":"tia portal test suite v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V20 Update 3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V20 Update 3","eol":null,"hubHref":"/vendor/siemens/tia_portal_test_suite_v20"},{"vendor":"siemens","product":"tia project-server","name":"TIA Project-Server","label":"tia project-server","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V2.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.2","eol":null,"hubHref":"/vendor/siemens/tia_project-server"},{"vendor":"siemens","product":"tia project-server v17","name":"TIA Project-Server V17","label":"tia project-server v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/tia_project-server_v17"},{"vendor":"siemens","product":"totally integrated automation portal (tia portal) v17","name":"Totally Integrated Automation Portal (TIA Portal) V17","label":"totally integrated automation portal (tia portal) v17","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V17 Update 9","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V17 Update 9","eol":null,"hubHref":"/vendor/siemens/totally_integrated_automation_portal_tia_portal_v17"},{"vendor":"siemens","product":"totally integrated automation portal (tia portal) v18","name":"Totally Integrated Automation Portal (TIA Portal) V18","label":"totally integrated automation portal (tia portal) v18","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V18 Update 6","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V18 Update 6","eol":null,"hubHref":"/vendor/siemens/totally_integrated_automation_portal_tia_portal_v18"},{"vendor":"siemens","product":"totally integrated automation portal (tia portal) v19","name":"Totally Integrated Automation Portal (TIA Portal) V19","label":"totally integrated automation portal (tia portal) v19","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V19 Update 4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V19 Update 4","eol":null,"hubHref":"/vendor/siemens/totally_integrated_automation_portal_tia_portal_v19"},{"vendor":"siemens","product":"totally integrated automation portal (tia portal) v20","name":"Totally Integrated Automation Portal (TIA Portal) V20","label":"totally integrated automation portal (tia portal) v20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V20 Update 4","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V20 Update 4","eol":null,"hubHref":"/vendor/siemens/totally_integrated_automation_portal_tia_portal_v20"},{"vendor":"siemens","product":"wincc panel image setup","name":"WinCC Panel Image Setup","label":"wincc panel image setup","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V17 Update 9","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V17 Update 9","eol":null,"hubHref":"/vendor/siemens/wincc_panel_image_setup"}],"affectedCount":139,"eol":{"hasEol":false,"count":0},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-282044.html","label":"cert-portal.siemens.com/productcert/html/ssa-282044.html","hostname":"cert-portal.siemens.com","tags":[]}],"lineage":{"upstream":[],"downstream":[],"duplicates":[],"related":[]},"timeline":[{"kind":"published","date":"2025-08-12T11:16:56.565Z","label":"Published","detail":"Vulnerability first disclosed.","source":null},{"kind":"modified","date":"2026-10-13T09:18:18.488Z","label":"Last modified","detail":"Vulnerability information updated.","source":null}],"risk":{"score":34,"level":"medium","profile":"Default","thresholds":{"critical":75,"high":50,"medium":25,"low":10}},"meta":{"dataAsOf":"2026-10-19T13:28:55.431Z","stale":false,"partial":false}}