{"schemaVersion":3,"id":"CVE-2025-40833","aliases":[],"status":"published","duplicateOf":null,"title":null,"description":"The affected devices contain a null pointer dereference vulnerability while processing specially crafted IPv4 requests. This could allow an attacker to cause denial of service condition. A manual restart is required to recover the system.","dates":{"published":"2026-05-12T08:20:46.879Z","modified":"2026-08-11T12:20:12.548Z","reserved":null,"kevAdded":[],"kevDue":[]},"cvss":{"headline":{"score":8.7,"severity":"high","version":"4.0","versionLabel":"v4.0","source":"CVE.org","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","computed":false,"selection":"backend-summary"},"metrics":[{"version":"4.0","versionLabel":"v4.0","source":"CVE.org","score":8.7,"severity":"high","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"CVE.org","score":7.5,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false},{"version":"4.0","versionLabel":"v4.0","source":"NVD","score":8.7,"severity":"high","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","exploitability":null,"impact":null,"computed":false},{"version":"3.1","versionLabel":"v3.1","source":"NVD","score":7.5,"severity":"high","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","exploitability":null,"impact":null,"computed":false}]},"epss":{"probability":0.00324,"percentile":0.23968,"severity":"low","asOf":"2026-10-19T00:00:00.000Z","change":{"pp":0,"baselineDate":"2026-09-19T00:00:00.000Z","baselineScore":0.00324},"history":[{"date":"2026-09-14T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-15T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-16T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-17T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-18T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-19T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.00324,"percentile":0.23968}],"last30":[{"date":"2026-09-19T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-20T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-21T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-22T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-23T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-24T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-25T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-26T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-27T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-28T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-29T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-09-30T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-01T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-02T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-03T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-04T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-05T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-06T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-07T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-08T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-09T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-10T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-11T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-12T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-13T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-14T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-15T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-16T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-17T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-18T00:00:00.000Z","score":0.00324,"percentile":null},{"date":"2026-10-19T00:00:00.000Z","score":0.00324,"percentile":0.23968}]},"kev":{"state":"not-listed","entries":[],"listedCount":0,"totalCatalogs":3,"catalogs":[{"source":"cisa","label":"CISA","listed":false,"entry":null},{"source":"enisa","label":"ENISA","listed":false,"entry":null},{"source":"circl","label":"CIRCL","listed":false,"entry":null}]},"ransomware":{"state":"none-recorded","sources":[]},"exploits":[],"exploitCount":0,"weaknesses":[{"id":"CWE-476","name":"NULL Pointer Dereference","description":"The product dereferences a pointer that it expects to be valid but is NULL.","type":"weakness","status":"Stable","abstraction":"Base","likelihoodOfExploit":"Medium","url":"https://cwe.mitre.org/data/definitions/476.html"}],"affected":[{"vendor":"siemens","product":"ie/pb link ha","name":"IE/PB LINK HA","label":"ie/pb link ha","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V4.1.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V4.1.2","eol":null,"hubHref":"/vendor/siemens/iepb_link_ha"},{"vendor":"siemens","product":"ie/pb link pn io","name":"IE/PB link PN IO","label":"ie/pb link pn io","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/iepb_link_pn_io"},{"vendor":"siemens","product":"ruggedcom_rm1224_lte\\(4g\\)_eu_firmware","name":"ruggedcom rm1224 lte\\(4g\\) eu firmware","label":"ruggedcom_rm1224_lte\\(4g\\)_eu_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/ruggedcom_rm1224_lte4g_eu"},{"vendor":"siemens","product":"ruggedcom_rm1224_lte\\(4g\\)_nam_firmware","name":"ruggedcom rm1224 lte\\(4g\\) nam firmware","label":"ruggedcom_rm1224_lte\\(4g\\)_nam_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/ruggedcom_rm1224_lte4g_nam"},{"vendor":"siemens","product":"scalance_m804pb_firmware","name":"scalance m804pb firmware","label":"scalance_m804pb_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m804pb"},{"vendor":"siemens","product":"scalance_m812-1_adsl-router_firmware","name":"scalance m812-1 adsl-router firmware","label":"scalance_m812-1_adsl-router_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m812-1_adsl-router"},{"vendor":"siemens","product":"scalance_m816-1_adsl-router_firmware","name":"scalance m816-1 adsl-router firmware","label":"scalance_m816-1_adsl-router_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m816-1_adsl-router"},{"vendor":"siemens","product":"scalance_m826-2_shdsl-router_firmware","name":"scalance m826-2 shdsl-router firmware","label":"scalance_m826-2_shdsl-router_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m826-2_shdsl-router"},{"vendor":"siemens","product":"scalance_m874-2_firmware","name":"scalance m874-2 firmware","label":"scalance_m874-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m874-2"},{"vendor":"siemens","product":"scalance_m874-3_firmware","name":"scalance m874-3 firmware","label":"scalance_m874-3_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m874-3"},{"vendor":"siemens","product":"scalance_m874-3_3g-router_\\(cn\\)_firmware","name":"scalance m874-3 3g-router \\(cn\\) firmware","label":"scalance_m874-3_3g-router_\\(cn\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m874-3_3g-router_cn"},{"vendor":"siemens","product":"scalance_m876-3_firmware","name":"scalance m876-3 firmware","label":"scalance_m876-3_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m876-3"},{"vendor":"siemens","product":"scalance_m876-3_\\(rok\\)_firmware","name":"scalance m876-3 \\(rok\\) firmware","label":"scalance_m876-3_\\(rok\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m876-3_rok"},{"vendor":"siemens","product":"scalance_m876-4_firmware","name":"scalance m876-4 firmware","label":"scalance_m876-4_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m876-4"},{"vendor":"siemens","product":"scalance_m876-4_\\(eu\\)_firmware","name":"scalance m876-4 \\(eu\\) firmware","label":"scalance_m876-4_\\(eu\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m876-4_eu"},{"vendor":"siemens","product":"scalance_m876-4_\\(nam\\)_firmware","name":"scalance m876-4 \\(nam\\) firmware","label":"scalance_m876-4_\\(nam\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_m876-4_nam"},{"vendor":"siemens","product":"scalance mub852-1 (a1)","name":"SCALANCE MUB852-1 (A1)","label":"scalance mub852-1 (a1)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mub852-1_a1"},{"vendor":"siemens","product":"scalance mub852-1 (b1)","name":"SCALANCE MUB852-1 (B1)","label":"scalance mub852-1 (b1)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mub852-1_b1"},{"vendor":"siemens","product":"scalance_mum853-1_\\(a1\\)_firmware","name":"scalance mum853-1 \\(a1\\) firmware","label":"scalance_mum853-1_\\(a1\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mum853-1_a1"},{"vendor":"siemens","product":"scalance_mum853-1_\\(b1\\)_firmware","name":"scalance mum853-1 \\(b1\\) firmware","label":"scalance_mum853-1_\\(b1\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mum853-1_b1"},{"vendor":"siemens","product":"scalance_mum853-1_\\(eu\\)_firmware","name":"scalance mum853-1 \\(eu\\) firmware","label":"scalance_mum853-1_\\(eu\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mum853-1_eu"},{"vendor":"siemens","product":"scalance_mum856-1_\\(a1\\)_firmware","name":"scalance mum856-1 \\(a1\\) firmware","label":"scalance_mum856-1_\\(a1\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mum856-1_a1"},{"vendor":"siemens","product":"scalance_mum856-1_\\(b1\\)_firmware","name":"scalance mum856-1 \\(b1\\) firmware","label":"scalance_mum856-1_\\(b1\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mum856-1_b1"},{"vendor":"siemens","product":"scalance_mum856-1_\\(cn\\)_firmware","name":"scalance mum856-1 \\(cn\\) firmware","label":"scalance_mum856-1_\\(cn\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mum856-1_cn"},{"vendor":"siemens","product":"scalance_mum856-1_\\(eu\\)_firmware","name":"scalance mum856-1 \\(eu\\) firmware","label":"scalance_mum856-1_\\(eu\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mum856-1_eu"},{"vendor":"siemens","product":"scalance_mum856-1_\\(row\\)_firmware","name":"scalance mum856-1 \\(row\\) firmware","label":"scalance_mum856-1_\\(row\\)_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_mum856-1_row"},{"vendor":"siemens","product":"scalance_s615_eec_lan-router_firmware","name":"scalance s615 eec lan-router firmware","label":"scalance_s615_eec_lan-router_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_s615_eec_lan-router"},{"vendor":"siemens","product":"scalance_s615_lan-router_firmware","name":"scalance s615 lan-router firmware","label":"scalance_s615_lan-router_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/scalance_s615_lan-router"},{"vendor":"siemens","product":"scalance_sc622-2c_firmware","name":"scalance sc622-2c firmware","label":"scalance_sc622-2c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2","eol":null,"hubHref":"/vendor/siemens/scalance_sc622-2c"},{"vendor":"siemens","product":"scalance_sc626-2c_firmware","name":"scalance sc626-2c firmware","label":"scalance_sc626-2c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2","eol":null,"hubHref":"/vendor/siemens/scalance_sc626-2c"},{"vendor":"siemens","product":"scalance_sc632-2c_firmware","name":"scalance sc632-2c firmware","label":"scalance_sc632-2c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2","eol":null,"hubHref":"/vendor/siemens/scalance_sc632-2c"},{"vendor":"siemens","product":"scalance_sc636-2c_firmware","name":"scalance sc636-2c firmware","label":"scalance_sc636-2c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2","eol":null,"hubHref":"/vendor/siemens/scalance_sc636-2c"},{"vendor":"siemens","product":"scalance_sc642-2c_firmware","name":"scalance sc642-2c firmware","label":"scalance_sc642-2c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2","eol":null,"hubHref":"/vendor/siemens/scalance_sc642-2c"},{"vendor":"siemens","product":"scalance_sc646-2c_firmware","name":"scalance sc646-2c firmware","label":"scalance_sc646-2c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2","eol":null,"hubHref":"/vendor/siemens/scalance_sc646-2c"},{"vendor":"siemens","product":"scalance_w1748-1_m12_firmware","name":"scalance w1748-1 m12 firmware","label":"scalance_w1748-1_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_w1748-1_m12"},{"vendor":"siemens","product":"scalance_w1788-1_m12_firmware","name":"scalance w1788-1 m12 firmware","label":"scalance_w1788-1_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_w1788-1_m12"},{"vendor":"siemens","product":"scalance_w1788-2_eec_m12_firmware","name":"scalance w1788-2 eec m12 firmware","label":"scalance_w1788-2_eec_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_w1788-2_eec_m12"},{"vendor":"siemens","product":"scalance_w1788-2_m12_firmware","name":"scalance w1788-2 m12 firmware","label":"scalance_w1788-2_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_w1788-2_m12"},{"vendor":"siemens","product":"scalance_w1788-2ia_m12_firmware","name":"scalance w1788-2ia m12 firmware","label":"scalance_w1788-2ia_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_w1788-2ia_m12"},{"vendor":"siemens","product":"scalance_w721-1_rj45_firmware","name":"scalance w721-1 rj45 firmware","label":"scalance_w721-1_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w721-1_rj45"},{"vendor":"siemens","product":"scalance_w722-1_rj45_firmware","name":"scalance w722-1 rj45 firmware","label":"scalance_w722-1_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w722-1_rj45"},{"vendor":"siemens","product":"scalance_w734-1_rj45_firmware","name":"scalance w734-1 rj45 firmware","label":"scalance_w734-1_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w734-1_rj45"},{"vendor":"siemens","product":"scalance w734-1 rj45 (usa)","name":"SCALANCE W734-1 RJ45 (USA)","label":"scalance w734-1 rj45 (usa)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w734-1_rj45_usa"},{"vendor":"siemens","product":"scalance_w738-1_m12_firmware","name":"scalance w738-1 m12 firmware","label":"scalance_w738-1_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w738-1_m12"},{"vendor":"siemens","product":"scalance_w748-1_m12_firmware","name":"scalance w748-1 m12 firmware","label":"scalance_w748-1_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w748-1_m12"},{"vendor":"siemens","product":"scalance w748-1 rj45","name":"SCALANCE W748-1 RJ45","label":"scalance w748-1 rj45","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w748-1_rj45"},{"vendor":"siemens","product":"scalance_w761-1_rj45_firmware","name":"scalance w761-1 rj45 firmware","label":"scalance_w761-1_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w761-1_rj45"},{"vendor":"siemens","product":"scalance_w774-1_m12_eec_firmware","name":"scalance w774-1 m12 eec firmware","label":"scalance_w774-1_m12_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w774-1_m12_eec"},{"vendor":"siemens","product":"scalance_w774-1_rj45_firmware","name":"scalance w774-1 rj45 firmware","label":"scalance_w774-1_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w774-1_rj45"},{"vendor":"siemens","product":"scalance w774-1 rj45 (usa)","name":"SCALANCE W774-1 RJ45 (USA)","label":"scalance w774-1 rj45 (usa)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w774-1_rj45_usa"},{"vendor":"siemens","product":"scalance_w778-1_m12_firmware","name":"scalance w778-1 m12 firmware","label":"scalance_w778-1_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w778-1_m12"},{"vendor":"siemens","product":"scalance_w778-1_m12_eec_firmware","name":"scalance w778-1 m12 eec firmware","label":"scalance_w778-1_m12_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w778-1_m12_eec"},{"vendor":"siemens","product":"scalance w778-1 m12 eec (usa)","name":"SCALANCE W778-1 M12 EEC (USA)","label":"scalance w778-1 m12 eec (usa)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w778-1_m12_eec_usa"},{"vendor":"siemens","product":"scalance_w786-1_rj45_firmware","name":"scalance w786-1 rj45 firmware","label":"scalance_w786-1_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w786-1_rj45"},{"vendor":"siemens","product":"scalance_w786-2_rj45_firmware","name":"scalance w786-2 rj45 firmware","label":"scalance_w786-2_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w786-2_rj45"},{"vendor":"siemens","product":"scalance_w786-2_sfp_firmware","name":"scalance w786-2 sfp firmware","label":"scalance_w786-2_sfp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w786-2_sfp"},{"vendor":"siemens","product":"scalance_w786-2ia_rj45_firmware","name":"scalance w786-2ia rj45 firmware","label":"scalance_w786-2ia_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w786-2ia_rj45"},{"vendor":"siemens","product":"scalance_w788-1_m12_firmware","name":"scalance w788-1 m12 firmware","label":"scalance_w788-1_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w788-1_m12"},{"vendor":"siemens","product":"scalance_w788-1_rj45_firmware","name":"scalance w788-1 rj45 firmware","label":"scalance_w788-1_rj45_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w788-1_rj45"},{"vendor":"siemens","product":"scalance_w788-2_m12_firmware","name":"scalance w788-2 m12 firmware","label":"scalance_w788-2_m12_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w788-2_m12"},{"vendor":"siemens","product":"scalance_w788-2_m12_eec_firmware","name":"scalance w788-2 m12 eec firmware","label":"scalance_w788-2_m12_eec_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w788-2_m12_eec"},{"vendor":"siemens","product":"scalance w788-2 rj45","name":"SCALANCE W788-2 RJ45","label":"scalance w788-2 rj45","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V6.6.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V6.6.0","eol":null,"hubHref":"/vendor/siemens/scalance_w788-2_rj45"},{"vendor":"siemens","product":"scalance wab762-1","name":"SCALANCE WAB762-1","label":"scalance wab762-1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wab762-1"},{"vendor":"siemens","product":"scalance_wam763-1_firmware","name":"scalance wam763-1 firmware","label":"scalance_wam763-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam763-1"},{"vendor":"siemens","product":"scalance wam763-1 (me)","name":"SCALANCE WAM763-1 (ME)","label":"scalance wam763-1 (me)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam763-1_me"},{"vendor":"siemens","product":"scalance wam763-1 (us)","name":"SCALANCE WAM763-1 (US)","label":"scalance wam763-1 (us)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam763-1_us"},{"vendor":"siemens","product":"scalance_wam766-1_firmware","name":"scalance wam766-1 firmware","label":"scalance_wam766-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam766-1"},{"vendor":"siemens","product":"scalance wam766-1 eec","name":"SCALANCE WAM766-1 EEC","label":"scalance wam766-1 eec","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam766-1_eec"},{"vendor":"siemens","product":"scalance wam766-1 eec (me)","name":"SCALANCE WAM766-1 EEC (ME)","label":"scalance wam766-1 eec (me)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam766-1_eec_me"},{"vendor":"siemens","product":"scalance wam766-1 eec (us)","name":"SCALANCE WAM766-1 EEC (US)","label":"scalance wam766-1 eec (us)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam766-1_eec_us"},{"vendor":"siemens","product":"scalance wam766-1 (me)","name":"SCALANCE WAM766-1 (ME)","label":"scalance wam766-1 (me)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam766-1_me"},{"vendor":"siemens","product":"scalance wam766-1 (us)","name":"SCALANCE WAM766-1 (US)","label":"scalance wam766-1 (us)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wam766-1_us"},{"vendor":"siemens","product":"scalance wub762-1","name":"SCALANCE WUB762-1","label":"scalance wub762-1","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wub762-1"},{"vendor":"siemens","product":"scalance wub762-1 ifeatures","name":"SCALANCE WUB762-1 iFeatures","label":"scalance wub762-1 ifeatures","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wub762-1_ifeatures"},{"vendor":"siemens","product":"scalance_wum763-1_firmware","name":"scalance wum763-1 firmware","label":"scalance_wum763-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wum763-1"},{"vendor":"siemens","product":"scalance wum763-1 (us)","name":"SCALANCE WUM763-1 (US)","label":"scalance wum763-1 (us)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wum763-1_us"},{"vendor":"siemens","product":"scalance_wum766-1_firmware","name":"scalance wum766-1 firmware","label":"scalance_wum766-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wum766-1"},{"vendor":"siemens","product":"scalance wum766-1 (me)","name":"SCALANCE WUM766-1 (ME)","label":"scalance wum766-1 (me)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wum766-1_me"},{"vendor":"siemens","product":"scalance wum766-1 (usa)","name":"SCALANCE WUM766-1 (USA)","label":"scalance wum766-1 (usa)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V3.2.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V3.2.0","eol":null,"hubHref":"/vendor/siemens/scalance_wum766-1_usa"},{"vendor":"siemens","product":"scalance_x204-2_firmware","name":"scalance x204-2 firmware","label":"scalance_x204-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x204-2"},{"vendor":"siemens","product":"scalance_x204-2fm_firmware","name":"scalance x204-2fm firmware","label":"scalance_x204-2fm_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x204-2fm"},{"vendor":"siemens","product":"scalance_x204-2ld_firmware","name":"scalance x204-2ld firmware","label":"scalance_x204-2ld_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x204-2ld"},{"vendor":"siemens","product":"scalance_x204-2ld_ts_firmware","name":"scalance x204-2ld ts firmware","label":"scalance_x204-2ld_ts_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x204-2ld_ts"},{"vendor":"siemens","product":"scalance_x204-2ts_firmware","name":"scalance x204-2ts firmware","label":"scalance_x204-2ts_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x204-2ts"},{"vendor":"siemens","product":"scalance_x206-1_firmware","name":"scalance x206-1 firmware","label":"scalance_x206-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x206-1"},{"vendor":"siemens","product":"scalance_x206-1ld_firmware","name":"scalance x206-1ld firmware","label":"scalance_x206-1ld_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x206-1ld"},{"vendor":"siemens","product":"scalance_x208_firmware","name":"scalance x208 firmware","label":"scalance_x208_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x208"},{"vendor":"siemens","product":"scalance_x208pro_firmware","name":"scalance x208pro firmware","label":"scalance_x208pro_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x208pro"},{"vendor":"siemens","product":"scalance_x212-2_firmware","name":"scalance x212-2 firmware","label":"scalance_x212-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x212-2"},{"vendor":"siemens","product":"scalance_x212-2ld_firmware","name":"scalance x212-2ld firmware","label":"scalance_x212-2ld_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x212-2ld"},{"vendor":"siemens","product":"scalance_x216_firmware","name":"scalance x216 firmware","label":"scalance_x216_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x216"},{"vendor":"siemens","product":"scalance_x224_firmware","name":"scalance x224 firmware","label":"scalance_x224_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x224"},{"vendor":"siemens","product":"scalance x302-7 eec (230v)","name":"SCALANCE X302-7 EEC (230V)","label":"scalance x302-7 eec (230v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x302-7_eec_230v"},{"vendor":"siemens","product":"scalance x302-7 eec (230v, coated)","name":"SCALANCE X302-7 EEC (230V, coated)","label":"scalance x302-7 eec (230v, coated)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x302-7_eec_230v_coated"},{"vendor":"siemens","product":"scalance x302-7 eec (24v)","name":"SCALANCE X302-7 EEC (24V)","label":"scalance x302-7 eec (24v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x302-7_eec_24v"},{"vendor":"siemens","product":"scalance x302-7 eec (24v, coated)","name":"SCALANCE X302-7 EEC (24V, coated)","label":"scalance x302-7 eec (24v, coated)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x302-7_eec_24v_coated"},{"vendor":"siemens","product":"scalance x302-7 eec (2x 230v)","name":"SCALANCE X302-7 EEC (2x 230V)","label":"scalance x302-7 eec (2x 230v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x302-7_eec_2x_230v"},{"vendor":"siemens","product":"scalance x302-7 eec (2x 230v, coated)","name":"SCALANCE X302-7 EEC (2x 230V, coated)","label":"scalance x302-7 eec (2x 230v, coated)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x302-7_eec_2x_230v_coated"},{"vendor":"siemens","product":"scalance x302-7 eec (2x 24v)","name":"SCALANCE X302-7 EEC (2x 24V)","label":"scalance x302-7 eec (2x 24v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x302-7_eec_2x_24v"},{"vendor":"siemens","product":"scalance x302-7 eec (2x 24v, coated)","name":"SCALANCE X302-7 EEC (2x 24V, coated)","label":"scalance x302-7 eec (2x 24v, coated)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x302-7_eec_2x_24v_coated"},{"vendor":"siemens","product":"scalance_x304-2fe_firmware","name":"scalance x304-2fe firmware","label":"scalance_x304-2fe_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x304-2fe"},{"vendor":"siemens","product":"scalance x306-1ld fe","name":"SCALANCE X306-1LD FE","label":"scalance x306-1ld fe","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x306-1ld_fe"},{"vendor":"siemens","product":"scalance x307-2 eec (230v)","name":"SCALANCE X307-2 EEC (230V)","label":"scalance x307-2 eec (230v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-2_eec_230v"},{"vendor":"siemens","product":"scalance x307-2 eec (230v, coated)","name":"SCALANCE X307-2 EEC (230V, coated)","label":"scalance x307-2 eec (230v, coated)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-2_eec_230v_coated"},{"vendor":"siemens","product":"scalance x307-2 eec (24v)","name":"SCALANCE X307-2 EEC (24V)","label":"scalance x307-2 eec (24v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-2_eec_24v"},{"vendor":"siemens","product":"scalance x307-2 eec (24v, coated)","name":"SCALANCE X307-2 EEC (24V, coated)","label":"scalance x307-2 eec (24v, coated)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-2_eec_24v_coated"},{"vendor":"siemens","product":"scalance x307-2 eec (2x 230v)","name":"SCALANCE X307-2 EEC (2x 230V)","label":"scalance x307-2 eec (2x 230v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-2_eec_2x_230v"},{"vendor":"siemens","product":"scalance x307-2 eec (2x 230v, coated)","name":"SCALANCE X307-2 EEC (2x 230V, coated)","label":"scalance x307-2 eec (2x 230v, coated)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-2_eec_2x_230v_coated"},{"vendor":"siemens","product":"scalance x307-2 eec (2x 24v)","name":"SCALANCE X307-2 EEC (2x 24V)","label":"scalance x307-2 eec (2x 24v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-2_eec_2x_24v"},{"vendor":"siemens","product":"scalance x307-2 eec (2x 24v, coated)","name":"SCALANCE X307-2 EEC (2x 24V, coated)","label":"scalance x307-2 eec (2x 24v, coated)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-2_eec_2x_24v_coated"},{"vendor":"siemens","product":"scalance_x307-3_firmware","name":"scalance x307-3 firmware","label":"scalance_x307-3_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-3"},{"vendor":"siemens","product":"scalance_x307-3ld_firmware","name":"scalance x307-3ld firmware","label":"scalance_x307-3ld_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x307-3ld"},{"vendor":"siemens","product":"scalance_x308-2_firmware","name":"scalance x308-2 firmware","label":"scalance_x308-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x308-2"},{"vendor":"siemens","product":"scalance x308-2 rd (inkl. siplus variants)","name":"SCALANCE X308-2 RD (inkl. SIPLUS variants)","label":"scalance x308-2 rd (inkl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x308-2_rd_inkl_siplus_variants"},{"vendor":"siemens","product":"scalance_x308-2ld_firmware","name":"scalance x308-2ld firmware","label":"scalance_x308-2ld_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x308-2ld"},{"vendor":"siemens","product":"scalance_x308-2lh_firmware","name":"scalance x308-2lh firmware","label":"scalance_x308-2lh_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x308-2lh"},{"vendor":"siemens","product":"scalance_x308-2m_firmware","name":"scalance x308-2m firmware","label":"scalance_x308-2m_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x308-2m"},{"vendor":"siemens","product":"scalance_x308-2m_poe_firmware","name":"scalance x308-2m poe firmware","label":"scalance_x308-2m_poe_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x308-2m_poe"},{"vendor":"siemens","product":"scalance_x308-2m_ts_firmware","name":"scalance x308-2m ts firmware","label":"scalance_x308-2m_ts_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x308-2m_ts"},{"vendor":"siemens","product":"scalance_x310_firmware","name":"scalance x310 firmware","label":"scalance_x310_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x310"},{"vendor":"siemens","product":"scalance_x310fe_firmware","name":"scalance x310fe firmware","label":"scalance_x310fe_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x310fe"},{"vendor":"siemens","product":"scalance x320-1 fe","name":"SCALANCE X320-1 FE","label":"scalance x320-1 fe","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x320-1_fe"},{"vendor":"siemens","product":"scalance x320-1-2ld fe","name":"SCALANCE X320-1-2LD FE","label":"scalance x320-1-2ld fe","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x320-1-2ld_fe"},{"vendor":"siemens","product":"scalance_x408-2_firmware","name":"scalance x408-2 firmware","label":"scalance_x408-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_x408-2"},{"vendor":"siemens","product":"scalance_xf204_firmware","name":"scalance xf204 firmware","label":"scalance_xf204_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xf204"},{"vendor":"siemens","product":"scalance_xf204-2_firmware","name":"scalance xf204-2 firmware","label":"scalance_xf204-2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xf204-2"},{"vendor":"siemens","product":"scalance_xf206-1_firmware","name":"scalance xf206-1 firmware","label":"scalance_xf206-1_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xf206-1"},{"vendor":"siemens","product":"scalance_xf208_firmware","name":"scalance xf208 firmware","label":"scalance_xf208_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xf208"},{"vendor":"siemens","product":"scalance_xm408-4c_firmware","name":"scalance xm408-4c firmware","label":"scalance_xm408-4c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xm408-4c"},{"vendor":"siemens","product":"scalance xm408-4c (l3 int.)","name":"SCALANCE XM408-4C (L3 int.)","label":"scalance xm408-4c (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xm408-4c_l3_int"},{"vendor":"siemens","product":"scalance_xm408-8c_firmware","name":"scalance xm408-8c firmware","label":"scalance_xm408-8c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xm408-8c"},{"vendor":"siemens","product":"scalance xm408-8c (l3 int.)","name":"SCALANCE XM408-8C (L3 int.)","label":"scalance xm408-8c (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xm408-8c_l3_int"},{"vendor":"siemens","product":"scalance_xm416-4c_firmware","name":"scalance xm416-4c firmware","label":"scalance_xm416-4c_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xm416-4c"},{"vendor":"siemens","product":"scalance xm416-4c (l3 int.)","name":"SCALANCE XM416-4C (L3 int.)","label":"scalance xm416-4c (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xm416-4c_l3_int"},{"vendor":"siemens","product":"scalance xr324-12m (230v, ports on front)","name":"SCALANCE XR324-12M (230V, ports on front)","label":"scalance xr324-12m (230v, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-12m_230v_ports_on_front"},{"vendor":"siemens","product":"scalance xr324-12m (230v, ports on rear)","name":"SCALANCE XR324-12M (230V, ports on rear)","label":"scalance xr324-12m (230v, ports on rear)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-12m_230v_ports_on_rear"},{"vendor":"siemens","product":"scalance xr324-12m (24v, ports on front)","name":"SCALANCE XR324-12M (24V, ports on front)","label":"scalance xr324-12m (24v, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-12m_24v_ports_on_front"},{"vendor":"siemens","product":"scalance xr324-12m (24v, ports on rear)","name":"SCALANCE XR324-12M (24V, ports on rear)","label":"scalance xr324-12m (24v, ports on rear)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-12m_24v_ports_on_rear"},{"vendor":"siemens","product":"scalance xr324-12m ts (24v)","name":"SCALANCE XR324-12M TS (24V)","label":"scalance xr324-12m ts (24v)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-12m_ts_24v"},{"vendor":"siemens","product":"scalance xr324-4m eec (100-240vac/60-250vdc, ports on front)","name":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","label":"scalance xr324-4m eec (100-240vac/60-250vdc, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_eec_100-240vac60-250vdc_ports_on_front"},{"vendor":"siemens","product":"scalance xr324-4m eec (100-240vac/60-250vdc, ports on rear)","name":"SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","label":"scalance xr324-4m eec (100-240vac/60-250vdc, ports on rear)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_eec_100-240vac60-250vdc_ports_on_rear"},{"vendor":"siemens","product":"scalance xr324-4m eec (24v, ports on front)","name":"SCALANCE XR324-4M EEC (24V, ports on front)","label":"scalance xr324-4m eec (24v, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_eec_24v_ports_on_front"},{"vendor":"siemens","product":"scalance xr324-4m eec (24v, ports on rear)","name":"SCALANCE XR324-4M EEC (24V, ports on rear)","label":"scalance xr324-4m eec (24v, ports on rear)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_eec_24v_ports_on_rear"},{"vendor":"siemens","product":"scalance xr324-4m eec (2x 100-240vac/60-250vdc, ports on front)","name":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","label":"scalance xr324-4m eec (2x 100-240vac/60-250vdc, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_eec_2x_100-240vac60-250vdc_ports_on_front"},{"vendor":"siemens","product":"scalance xr324-4m eec (2x 100-240vac/60-250vdc, ports on rear)","name":"SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","label":"scalance xr324-4m eec (2x 100-240vac/60-250vdc, ports on rear)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_eec_2x_100-240vac60-250vdc_ports_on_rear"},{"vendor":"siemens","product":"scalance xr324-4m eec (2x 24v, ports on front)","name":"SCALANCE XR324-4M EEC (2x 24V, ports on front)","label":"scalance xr324-4m eec (2x 24v, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_eec_2x_24v_ports_on_front"},{"vendor":"siemens","product":"scalance xr324-4m eec (2x 24v, ports on rear)","name":"SCALANCE XR324-4M EEC (2x 24V, ports on rear)","label":"scalance xr324-4m eec (2x 24v, ports on rear)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_eec_2x_24v_ports_on_rear"},{"vendor":"siemens","product":"scalance xr324-4m poe (230v, ports on front)","name":"SCALANCE XR324-4M PoE (230V, ports on front)","label":"scalance xr324-4m poe (230v, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_poe_230v_ports_on_front"},{"vendor":"siemens","product":"scalance xr324-4m poe (230v, ports on rear)","name":"SCALANCE XR324-4M PoE (230V, ports on rear)","label":"scalance xr324-4m poe (230v, ports on rear)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_poe_230v_ports_on_rear"},{"vendor":"siemens","product":"scalance xr324-4m poe (24v, ports on front)","name":"SCALANCE XR324-4M PoE (24V, ports on front)","label":"scalance xr324-4m poe (24v, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_poe_24v_ports_on_front"},{"vendor":"siemens","product":"scalance xr324-4m poe (24v, ports on rear)","name":"SCALANCE XR324-4M PoE (24V, ports on rear)","label":"scalance xr324-4m poe (24v, ports on rear)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_poe_24v_ports_on_rear"},{"vendor":"siemens","product":"scalance xr324-4m poe ts (24v, ports on front)","name":"SCALANCE XR324-4M PoE TS (24V, ports on front)","label":"scalance xr324-4m poe ts (24v, ports on front)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr324-4m_poe_ts_24v_ports_on_front"},{"vendor":"siemens","product":"scalance xr524-8c, 1x230v","name":"SCALANCE XR524-8C, 1x230V","label":"scalance xr524-8c, 1x230v","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr524-8c_1x230v"},{"vendor":"siemens","product":"scalance xr524-8c, 1x230v (l3 int.)","name":"SCALANCE XR524-8C, 1x230V (L3 int.)","label":"scalance xr524-8c, 1x230v (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr524-8c_1x230v_l3_int"},{"vendor":"siemens","product":"scalance xr524-8c, 24v","name":"SCALANCE XR524-8C, 24V","label":"scalance xr524-8c, 24v","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr524-8c_24v"},{"vendor":"siemens","product":"scalance xr524-8c, 24v (l3 int.)","name":"SCALANCE XR524-8C, 24V (L3 int.)","label":"scalance xr524-8c, 24v (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr524-8c_24v_l3_int"},{"vendor":"siemens","product":"scalance xr524-8c, 2x230v","name":"SCALANCE XR524-8C, 2x230V","label":"scalance xr524-8c, 2x230v","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr524-8c_2x230v"},{"vendor":"siemens","product":"scalance xr524-8c, 2x230v (l3 int.)","name":"SCALANCE XR524-8C, 2x230V (L3 int.)","label":"scalance xr524-8c, 2x230v (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr524-8c_2x230v_l3_int"},{"vendor":"siemens","product":"scalance xr526-8c, 1x230v","name":"SCALANCE XR526-8C, 1x230V","label":"scalance xr526-8c, 1x230v","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr526-8c_1x230v"},{"vendor":"siemens","product":"scalance xr526-8c, 1x230v (l3 int.)","name":"SCALANCE XR526-8C, 1x230V (L3 int.)","label":"scalance xr526-8c, 1x230v (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr526-8c_1x230v_l3_int"},{"vendor":"siemens","product":"scalance xr526-8c, 24v","name":"SCALANCE XR526-8C, 24V","label":"scalance xr526-8c, 24v","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr526-8c_24v"},{"vendor":"siemens","product":"scalance xr526-8c, 24v (l3 int.)","name":"SCALANCE XR526-8C, 24V (L3 int.)","label":"scalance xr526-8c, 24v (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr526-8c_24v_l3_int"},{"vendor":"siemens","product":"scalance xr526-8c, 2x230v","name":"SCALANCE XR526-8C, 2x230V","label":"scalance xr526-8c, 2x230v","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr526-8c_2x230v"},{"vendor":"siemens","product":"scalance xr526-8c, 2x230v (l3 int.)","name":"SCALANCE XR526-8C, 2x230V (L3 int.)","label":"scalance xr526-8c, 2x230v (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr526-8c_2x230v_l3_int"},{"vendor":"siemens","product":"scalance_xr528-6m_firmware","name":"scalance xr528-6m firmware","label":"scalance_xr528-6m_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr528-6m"},{"vendor":"siemens","product":"scalance_xr528-6m_2hr2_firmware","name":"scalance xr528-6m 2hr2 firmware","label":"scalance_xr528-6m_2hr2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr528-6m_2hr2"},{"vendor":"siemens","product":"scalance xr528-6m (2hr2, l3 int.)","name":"SCALANCE XR528-6M (2HR2, L3 int.)","label":"scalance xr528-6m (2hr2, l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr528-6m_2hr2_l3_int"},{"vendor":"siemens","product":"scalance xr528-6m (l3 int.)","name":"SCALANCE XR528-6M (L3 int.)","label":"scalance xr528-6m (l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr528-6m_l3_int"},{"vendor":"siemens","product":"scalance_xr552-12m_firmware","name":"scalance xr552-12m firmware","label":"scalance_xr552-12m_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr552-12m"},{"vendor":"siemens","product":"scalance_xr552-12m_2hr2_firmware","name":"scalance xr552-12m 2hr2 firmware","label":"scalance_xr552-12m_2hr2_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr552-12m_2hr2"},{"vendor":"siemens","product":"scalance xr552-12m (2hr2, l3 int.)","name":"SCALANCE XR552-12M (2HR2, L3 int.)","label":"scalance xr552-12m (2hr2, l3 int.)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/scalance_xr552-12m_2hr2_l3_int"},{"vendor":"siemens","product":"simatic_cfu_diq_firmware","name":"simatic cfu diq firmware","label":"simatic_cfu_diq_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V2.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.0.0","eol":null,"hubHref":"/vendor/siemens/simatic_cfu_diq"},{"vendor":"siemens","product":"simatic_cfu_pa_firmware","name":"simatic cfu pa firmware","label":"simatic_cfu_pa_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"< V2.0.0","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V2.0.0","eol":null,"hubHref":"/vendor/siemens/simatic_cfu_pa"},{"vendor":"siemens","product":"simatic et 200pro im 154-8 pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8 PN/DP CPU","label":"simatic et 200pro im 154-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200pro im 154-8f pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8F PN/DP CPU","label":"simatic et 200pro im 154-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8f_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200pro im 154-8fx pn/dp cpu","name":"SIMATIC ET 200pro IM 154-8FX PN/DP CPU","label":"simatic et 200pro im 154-8fx pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200pro_im_154-8fx_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200s im 151-8 pn/dp cpu","name":"SIMATIC ET 200S IM 151-8 PN/DP CPU","label":"simatic et 200s im 151-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200s_im_151-8_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200s im 151-8f pn/dp cpu","name":"SIMATIC ET 200S IM 151-8F PN/DP CPU","label":"simatic et 200s im 151-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200s_im_151-8f_pndp_cpu"},{"vendor":"siemens","product":"simatic et 200sp cpu 1510sp f-1 pn","name":"SIMATIC ET 200SP CPU 1510SP F-1 PN","label":"simatic et 200sp cpu 1510sp f-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_cpu_1510sp_f-1_pn"},{"vendor":"siemens","product":"simatic et 200sp cpu 1510sp-1 pn","name":"SIMATIC ET 200SP CPU 1510SP-1 PN","label":"simatic et 200sp cpu 1510sp-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_cpu_1510sp-1_pn"},{"vendor":"siemens","product":"simatic et 200sp cpu 1512sp f-1 pn","name":"SIMATIC ET 200SP CPU 1512SP F-1 PN","label":"simatic et 200sp cpu 1512sp f-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_cpu_1512sp_f-1_pn"},{"vendor":"siemens","product":"simatic et 200sp cpu 1512sp-1 pn","name":"SIMATIC ET 200SP CPU 1512SP-1 PN","label":"simatic et 200sp cpu 1512sp-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_cpu_1512sp-1_pn"},{"vendor":"siemens","product":"simatic et 200sp ha im155-6 pn","name":"SIMATIC ET 200SP HA IM155-6 PN","label":"simatic et 200sp ha im155-6 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V1.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V1.3","eol":null,"hubHref":"/vendor/siemens/simatic_et_200sp_ha_im155-6_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1511-1 pn","name":"SIMATIC S7-1500 CPU 1511-1 PN","label":"simatic s7-1500 cpu 1511-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1511-1_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1511f-1 pn","name":"SIMATIC S7-1500 CPU 1511F-1 PN","label":"simatic s7-1500 cpu 1511f-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1511f-1_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1513-1 pn","name":"SIMATIC S7-1500 CPU 1513-1 PN","label":"simatic s7-1500 cpu 1513-1 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1513-1_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1515-2 pn","name":"SIMATIC S7-1500 CPU 1515-2 PN","label":"simatic s7-1500 cpu 1515-2 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1515-2_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1515f-2 pn","name":"SIMATIC S7-1500 CPU 1515F-2 PN","label":"simatic s7-1500 cpu 1515f-2 pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1515f-2_pn"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1516-3 pn/dp","name":"SIMATIC S7-1500 CPU 1516-3 PN/DP","label":"simatic s7-1500 cpu 1516-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1516-3_pndp"},{"vendor":"siemens","product":"simatic s7-1500 cpu 1516f-3 pn/dp","name":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","label":"simatic s7-1500 cpu 1516f-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-1500_cpu_1516f-3_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 314c-2 pn/dp","name":"SIMATIC S7-300 CPU 314C-2 PN/DP","label":"simatic s7-300 cpu 314c-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_314c-2_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_315-2_pn\\/dp_firmware","name":"simatic s7-300 cpu 315-2 pn\\/dp firmware","label":"simatic_s7-300_cpu_315-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 315f-2 pn/dp","name":"SIMATIC S7-300 CPU 315F-2 PN/DP","label":"simatic s7-300 cpu 315f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315f-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 315t-3 pn/dp","name":"SIMATIC S7-300 CPU 315T-3 PN/DP","label":"simatic s7-300 cpu 315t-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_315t-3_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_317-2_pn\\/dp_firmware","name":"simatic s7-300 cpu 317-2 pn\\/dp firmware","label":"simatic_s7-300_cpu_317-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317f-2 pn/dp","name":"SIMATIC S7-300 CPU 317F-2 PN/DP","label":"simatic s7-300 cpu 317f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317f-2_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317t-3 pn/dp","name":"SIMATIC S7-300 CPU 317T-3 PN/DP","label":"simatic s7-300 cpu 317t-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317t-3_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 317tf-3 pn/dp","name":"SIMATIC S7-300 CPU 317TF-3 PN/DP","label":"simatic s7-300 cpu 317tf-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_317tf-3_pndp"},{"vendor":"siemens","product":"simatic_s7-300_cpu_319-3_pn\\/dp_firmware","name":"simatic s7-300 cpu 319-3 pn\\/dp firmware","label":"simatic_s7-300_cpu_319-3_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_319-3_pndp"},{"vendor":"siemens","product":"simatic s7-300 cpu 319f-3 pn/dp","name":"SIMATIC S7-300 CPU 319F-3 PN/DP","label":"simatic s7-300 cpu 319f-3 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-300_cpu_319f-3_pndp"},{"vendor":"siemens","product":"simatic s7-400 cpu 412-2 pn v7","name":"SIMATIC S7-400 CPU 412-2 PN V7","label":"simatic s7-400 cpu 412-2 pn v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_412-2_pn_v7"},{"vendor":"siemens","product":"simatic s7-400 cpu 414-3 pn/dp v7","name":"SIMATIC S7-400 CPU 414-3 PN/DP V7","label":"simatic s7-400 cpu 414-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_414-3_pndp_v7"},{"vendor":"siemens","product":"simatic s7-400 cpu 414f-3 pn/dp v7","name":"SIMATIC S7-400 CPU 414F-3 PN/DP V7","label":"simatic s7-400 cpu 414f-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_414f-3_pndp_v7"},{"vendor":"siemens","product":"simatic s7-400 cpu 416-3 pn/dp v7","name":"SIMATIC S7-400 CPU 416-3 PN/DP V7","label":"simatic s7-400 cpu 416-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_416-3_pndp_v7"},{"vendor":"siemens","product":"simatic s7-400 cpu 416f-3 pn/dp v7","name":"SIMATIC S7-400 CPU 416F-3 PN/DP V7","label":"simatic s7-400 cpu 416f-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_cpu_416f-3_pndp_v7"},{"vendor":"siemens","product":"simatic s7-400 h v6 cpu family (incl. siplus variants)","name":"SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)","label":"simatic s7-400 h v6 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simatic_s7-400_h_v6_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-410 v10 cpu family (incl. siplus variants)","name":"SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)","label":"simatic s7-410 v10 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V10.2","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V10.2","eol":null,"hubHref":"/vendor/siemens/simatic_s7-410_v10_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simatic s7-410 v8 cpu family (incl. siplus variants)","name":"SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)","label":"simatic s7-410 v8 cpu family (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"< V8.3","noFixRecorded":false,"fixedIn":null}],"versionsText":"< V8.3","eol":null,"hubHref":"/vendor/siemens/simatic_s7-410_v8_cpu_family_incl_siplus_variants"},{"vendor":"siemens","product":"simit unit v10","name":"SIMIT UNIT V10","label":"simit unit v10","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simit_unit_v10"},{"vendor":"siemens","product":"simit unit v11","name":"SIMIT UNIT V11","label":"simit unit v11","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/simit_unit_v11"},{"vendor":"siemens","product":"sinamics cbe20","name":"SINAMICS CBE20","label":"sinamics cbe20","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_cbe20"},{"vendor":"siemens","product":"sinamics g115d","name":"SINAMICS G115D","label":"sinamics g115d","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_g115d"},{"vendor":"siemens","product":"sinamics g120 (incl. siplus variants)","name":"SINAMICS G120 (incl. SIPLUS variants)","label":"sinamics g120 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_g120_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics_g120c","name":"sinamics g120c","label":"sinamics_g120c","ecosystem":null,"cpePart":"h","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_g120c"},{"vendor":"siemens","product":"sinamics_g120d","name":"sinamics g120d","label":"sinamics_g120d","ecosystem":null,"cpePart":"h","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_g120d"},{"vendor":"siemens","product":"sinamics g120x","name":"SINAMICS G120X","label":"sinamics g120x","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_g120x"},{"vendor":"siemens","product":"sinamics g120xa","name":"SINAMICS G120XA","label":"sinamics g120xa","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_g120xa"},{"vendor":"siemens","product":"sinamics_g130_firmware","name":"sinamics g130 firmware","label":"sinamics_g130_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_g130"},{"vendor":"siemens","product":"sinamics_g150_firmware","name":"sinamics g150 firmware","label":"sinamics_g150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_g150"},{"vendor":"siemens","product":"sinamics_s110_firmware","name":"sinamics s110 firmware","label":"sinamics_s110_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_s110"},{"vendor":"siemens","product":"sinamics s120 (incl. siplus variants)","name":"SINAMICS S120 (incl. SIPLUS variants)","label":"sinamics s120 (incl. siplus variants)","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_s120_incl_siplus_variants"},{"vendor":"siemens","product":"sinamics_s150_firmware","name":"sinamics s150 firmware","label":"sinamics_s150_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinamics_s150"},{"vendor":"siemens","product":"sinumerik_840d_sl","name":"sinumerik 840d sl","label":"sinumerik_840d_sl","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sinumerik_840d_sl"},{"vendor":"siemens","product":"siplus et 200s im 151-8 pn/dp cpu","name":"SIPLUS ET 200S IM 151-8 PN/DP CPU","label":"siplus et 200s im 151-8 pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200s_im_151-8_pndp_cpu"},{"vendor":"siemens","product":"siplus et 200s im 151-8f pn/dp cpu","name":"SIPLUS ET 200S IM 151-8F PN/DP CPU","label":"siplus et 200s im 151-8f pn/dp cpu","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_et_200s_im_151-8f_pndp_cpu"},{"vendor":"siemens","product":"siplus net ie/pb link pn io","name":"SIPLUS NET IE/PB link PN IO","label":"siplus net ie/pb link pn io","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_net_iepb_link_pn_io"},{"vendor":"siemens","product":"siplus s7-300 cpu 314c-2 pn/dp","name":"SIPLUS S7-300 CPU 314C-2 PN/DP","label":"siplus s7-300 cpu 314c-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_314c-2_pndp"},{"vendor":"siemens","product":"siplus_s7-300_cpu_315-2_pn\\/dp_firmware","name":"siplus s7-300 cpu 315-2 pn\\/dp firmware","label":"siplus_s7-300_cpu_315-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_315-2_pndp"},{"vendor":"siemens","product":"siplus s7-300 cpu 315f-2 pn/dp","name":"SIPLUS S7-300 CPU 315F-2 PN/DP","label":"siplus s7-300 cpu 315f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_315f-2_pndp"},{"vendor":"siemens","product":"siplus_s7-300_cpu_317-2_pn\\/dp_firmware","name":"siplus s7-300 cpu 317-2 pn\\/dp firmware","label":"siplus_s7-300_cpu_317-2_pn\\/dp_firmware","ecosystem":null,"cpePart":"o","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_317-2_pndp"},{"vendor":"siemens","product":"siplus s7-300 cpu 317f-2 pn/dp","name":"SIPLUS S7-300 CPU 317F-2 PN/DP","label":"siplus s7-300 cpu 317f-2 pn/dp","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-300_cpu_317f-2_pndp"},{"vendor":"siemens","product":"siplus s7-400 cpu 414-3 pn/dp v7","name":"SIPLUS S7-400 CPU 414-3 PN/DP V7","label":"siplus s7-400 cpu 414-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-400_cpu_414-3_pndp_v7"},{"vendor":"siemens","product":"siplus s7-400 cpu 416-3 pn/dp v7","name":"SIPLUS S7-400 CPU 416-3 PN/DP V7","label":"siplus s7-400 cpu 416-3 pn/dp v7","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/siplus_s7-400_cpu_416-3_pndp_v7"},{"vendor":"siemens","product":"sitop psu8600 1ac 20 a/4x5 a pn","name":"SITOP PSU8600 1AC 20 A/4x5 A PN","label":"sitop psu8600 1ac 20 a/4x5 a pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_psu8600_1ac_20_a4x5_a_pn"},{"vendor":"siemens","product":"sitop psu8600 3ac 20 a pn","name":"SITOP PSU8600 3AC 20 A PN","label":"sitop psu8600 3ac 20 a pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_psu8600_3ac_20_a_pn"},{"vendor":"siemens","product":"sitop psu8600 3ac 20 a/4x5 a pn","name":"SITOP PSU8600 3AC 20 A/4x5 A PN","label":"sitop psu8600 3ac 20 a/4x5 a pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_psu8600_3ac_20_a4x5_a_pn"},{"vendor":"siemens","product":"sitop psu8600 3ac 40 a pn","name":"SITOP PSU8600 3AC 40 A PN","label":"sitop psu8600 3ac 40 a pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_psu8600_3ac_40_a_pn"},{"vendor":"siemens","product":"sitop psu8600 3ac 40 a/4x10 a pn","name":"SITOP PSU8600 3AC 40 A/4x10 A PN","label":"sitop psu8600 3ac 40 a/4x10 a pn","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_psu8600_3ac_40_a4x10_a_pn"},{"vendor":"siemens","product":"sitop psu8600 3ac 40 a/4x10a eip","name":"SITOP PSU8600 3AC 40 A/4x10A EIP","label":"sitop psu8600 3ac 40 a/4x10a eip","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_psu8600_3ac_40_a4x10a_eip"},{"vendor":"siemens","product":"sitop ups1600 10 a ethernet/ profinet","name":"SITOP UPS1600 10 A Ethernet/ PROFINET","label":"sitop ups1600 10 a ethernet/ profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_ups1600_10_a_ethernet_profinet"},{"vendor":"siemens","product":"sitop ups1600 20 a ethernet/ profinet","name":"SITOP UPS1600 20 A Ethernet/ PROFINET","label":"sitop ups1600 20 a ethernet/ profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_ups1600_20_a_ethernet_profinet"},{"vendor":"siemens","product":"sitop ups1600 40 a ethernet/ profinet","name":"SITOP UPS1600 40 A Ethernet/ PROFINET","label":"sitop ups1600 40 a ethernet/ profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_ups1600_40_a_ethernet_profinet"},{"vendor":"siemens","product":"sitop ups1600 ex 20 a ethernet profinet","name":"SITOP UPS1600 EX 20 A Ethernet PROFINET","label":"sitop ups1600 ex 20 a ethernet profinet","ecosystem":null,"cpePart":"a","purl":null,"purlType":null,"versions":[{"text":"All versions","noFixRecorded":true,"fixedIn":null}],"versionsText":"All versions (No fix recorded)","eol":null,"hubHref":"/vendor/siemens/sitop_ups1600_ex_20_a_ethernet_profinet"}],"affectedCount":243,"eol":{"hasEol":false,"count":0},"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-392349.html","label":"cert-portal.siemens.com/productcert/html/ssa-392349.html","hostname":"cert-portal.siemens.com","tags":[]}],"lineage":{"upstream":[],"downstream":[],"duplicates":[],"related":[]},"timeline":[{"kind":"published","date":"2026-05-12T08:20:46.879Z","label":"Published","detail":"Vulnerability first disclosed.","source":null},{"kind":"modified","date":"2026-08-11T12:20:12.548Z","label":"Last modified","detail":"Vulnerability information updated.","source":null}],"risk":{"score":35,"level":"medium","profile":"Default","thresholds":{"critical":75,"high":50,"medium":25,"low":10}},"meta":{"dataAsOf":"2026-10-20T03:40:57.615Z","stale":false,"partial":false}}