[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"repo-stars":3,"vuln-CVE-2026-16876":6},{"stargazers_count":4,"fetched_at":5},7,"2026-09-07T05:55:14.258Z",{"id":7,"descriptions":8,"cisa":9,"weaknesses":10,"exploits":40,"aliases":41,"duplicate_of":9,"upstream":42,"downstream":43,"duplicates":44,"related":45,"reserved_at":9,"published_at":46,"modified_at":46,"state":47,"summary":48,"references_raw":55,"kevs":60,"epss":9,"epss_history":61,"metrics":62,"affected":66},"CVE-2026-16876","An authentication bypass vulnerability exists in the WebGUI of Series UNIVERGE IX-R/IX-V. A user could bypass authentication and execute arbitrary CLI commands by tampering with WebGUI messages and sending them to the device via internet.",null,[11],{"_key":12,"id":12,"name":13,"description":14,"type":15,"status":16,"abstraction":17,"likelihood_of_exploit":18,"capec":19},"CWE-306","Missing Authentication for Critical Function","The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.","weakness","Draft","Base","High",[20,24,28,32,36],{"id":21,"name":22,"techniques":23},"CAPEC-12","Choosing Message Identifier",[],{"id":25,"name":26,"techniques":27},"CAPEC-166","Force the System to Reset Values",[],{"id":29,"name":30,"techniques":31},"CAPEC-216","Communication Channel Manipulation",[],{"id":33,"name":34,"techniques":35},"CAPEC-36","Using Unpublished Interfaces or Functionality",[],{"id":37,"name":38,"techniques":39},"CAPEC-62","Cross Site Request Forgery",[],[],[],[],[],[],[],"2026-09-07T00:48:01.015Z","PUBLISHED",{"cisa_kev":49,"cisa_ransomware":49,"cisa_vendor":9,"epss_severity":9,"epss_score":9,"severity":50,"severity_score":51,"severity_version":52,"severity_source":53,"severity_vector":54,"severity_status":47},false,"critical",9.3,"v4.0","cve.org","CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",[56],{"url":57,"sources":58,"tags":59},"https://jpn.nec.com/security-info/secinfo/nv26-005_en.html",[53],[],[],[],[63],{"source":53,"cvss_v2_0":9,"cvss_v3_0":9,"cvss_v3_1":9,"cvss_v4_0":64},{"baseScore":51,"baseSeverity":65,"vectorString":54,"impactScore":9,"exploitabilityScore":9},"CRITICAL",[67],{"ecosystem":9,"name":68,"vendor":69,"product":70,"cpe_part":71,"purl_type":9,"purl_namespace":9,"purl_name":9,"source":9,"versions":72},"UNIVERGE IX-R/IX-V","nec corporation","univerge ix-r/ix-v","a",[73],{"version":74,"is_range":49,"range_type":53,"version_start":74,"version_start_type":75,"version_end":74,"version_end_type":75,"fixed_in":9},"All versions from Ver1.1 through Ver1.3, All versions from Ver1.4.21 through Ver1.4.28 and Ver1.5.23","including"]