ABB Terra Ac Wallbox Ul32A vulnerabilities

3 vulnerabilities

Known vulnerabilities in ABB Terra Ac Wallbox Ul32A, newest first, with CVSS severity, EPSS, KEV listings, ransomware use and the affected versions.

6.8MediumCVE-2025-5517abb · terra_ac_wallbox_jp_firmware +5 moreHeap Memory Corruption VulnerabilityHeap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.EPSS0.28%8.8HighCVE-2023-0863abb · terra_ac_wallbox_80a_firmware +11 moreAuthentication to access the AC wallbox via its Bluetooth Low Energy (BLE) channel can be bypassed,Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.EPSS0.35%7.1HighCVE-2023-0864abb · terra_ac_wallbox_80a_firmware +11 moreConfiguration data is exchanged in plaintext and could be available to a nearby attacker if present during configuration or usage of the device via Bluetooth Low Energy (BLE).Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.EPSS0.16%