Apc vulnerabilities
11 vulnerabilities
Known vulnerabilities in Apc products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 9 products.
Products
9- Powerchute4 vulnerabilities
- Ap96062 vulnerabilities
- Apcupsd2 vulnerabilities
- Ap7932 B21 vulnerabilities
- Network Management Card 41 vulnerabilities
- Oas1 vulnerabilities
- Switched Rack Pdu1 vulnerabilities
- Network Management Card0 vulnerabilities
- Powerchute Network Shutdown0 vulnerabilities
CVE-2003-0099apcapcupsd+1
EPSS score0.55%
Multiple buffer overflows in apcupsd before 3.8.6, and 3.10.x before 3.10.5, may allow attackers to cause a denial of service or execute arbitrary code, related to usage of the vsprintf function.CVE-2007-6226apcoas+1EPSS score1.85%
The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login attempt once the other client exits.CVE-2020-7526apcpowerchuteEPSS score2.27%
Improper Input Validation vulnerability exists in PowerChute Business Edition (software V9.0.x and earlier) which could cause remote code execution when a script is executed during a shutdown event.CVE-2001-0564apcap9606EPSS score3.21%
APC Web/SNMP Management Card prior to Firmware 310 only supports one telnet connection, which allows a remote attacker to create a denial of service via repeated failed logon attempts which temporarily locks the card.CVE-2001-0040apcapcupsdEPSS score0.86%
APC UPS daemon, apcupsd, saves its process ID in a world-writable file, which allows local users to kill an arbitrary process by specifying the target process ID in the apcupsd.pid file.CVE-2011-4263apcpowerchuteEPSS score0.84%
Cross-site scripting (XSS) vulnerability in Schneider Electric PowerChute Business Edition before 8.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.CVE-2004-2046apcpowerchuteEPSS score2.61%
Unknown vulnerability in APC PowerChute Business Edition 6.0 through 7.0.1 allows remote attackers to cause a denial of service via unknown attack vectors.CVE-2004-0311apcap9606EPSS score2.47%
American Power Conversion (APC) Web/SNMP Management SmartSlot Card 3.0 through 3.0.3 and 3.21 are shipped with a default password of TENmanUFactOryPOWER, which allows remote attackers to gain unauthorized access.CVE-2024-58310apcnetwork management card 4EPSS score0.90%
APC Network Management Card 4 contains a path traversal vulnerability that allows unauthenticated attackers to access sensitive system files by manipulating URL parameters. Attackers can exploit directory traversal techniques to read critical system files like /etc/passwd by using encoded path traversal characters in HTTP requests.CVE-2002-1924apcpowerchuteEPSS score1.35%
PowerChute plus 5.0.2 creates a "Pwrchute" directory during installation that is shared and world writeable, which could allow remote attackers to modify or create files in that directory.CVE-2009-4406apcap7932_b2_firmwareEPSS score1.13%
Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the login_username parameter.