Apc vulnerabilities

11 vulnerabilities

Known vulnerabilities in Apc products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 9 products.

Products

9
7.2CVE-2003-0099apcapcupsd+1
EPSS score
0.55%
Multiple buffer overflows in apcupsd before 3.8.6, and 3.10.x before 3.10.5, may allow attackers to cause a denial of service or execute arbitrary code, related to usage of the vsprintf function.
7.1CVE-2007-6226apcoas+1
EPSS score
1.85%
The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login attempt once the other client exits.
8.8CVE-2020-7526apcpowerchute
EPSS score
2.27%
Improper Input Validation vulnerability exists in PowerChute Business Edition (software V9.0.x and earlier) which could cause remote code execution when a script is executed during a shutdown event.
5CVE-2001-0564apcap9606
EPSS score
3.21%
APC Web/SNMP Management Card prior to Firmware 310 only supports one telnet connection, which allows a remote attacker to create a denial of service via repeated failed logon attempts which temporarily locks the card.
2.1CVE-2001-0040apcapcupsd
EPSS score
0.86%
APC UPS daemon, apcupsd, saves its process ID in a world-writable file, which allows local users to kill an arbitrary process by specifying the target process ID in the apcupsd.pid file.
4.3CVE-2011-4263apcpowerchute
EPSS score
0.84%
Cross-site scripting (XSS) vulnerability in Schneider Electric PowerChute Business Edition before 8.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
5CVE-2004-2046apcpowerchute
EPSS score
2.61%
Unknown vulnerability in APC PowerChute Business Edition 6.0 through 7.0.1 allows remote attackers to cause a denial of service via unknown attack vectors.
10CVE-2004-0311apcap9606
EPSS score
2.47%
American Power Conversion (APC) Web/SNMP Management SmartSlot Card 3.0 through 3.0.3 and 3.21 are shipped with a default password of TENmanUFactOryPOWER, which allows remote attackers to gain unauthorized access.
8.7CVE-2024-58310apcnetwork management card 4
EPSS score
0.90%
APC Network Management Card 4 contains a path traversal vulnerability that allows unauthenticated attackers to access sensitive system files by manipulating URL parameters. Attackers can exploit directory traversal techniques to read critical system files like /etc/passwd by using encoded path traversal characters in HTTP requests.
5CVE-2002-1924apcpowerchute
EPSS score
1.35%
PowerChute plus 5.0.2 creates a "Pwrchute" directory during installation that is shared and world writeable, which could allow remote attackers to modify or create files in that directory.
4.3CVE-2009-4406apcap7932_b2_firmware
EPSS score
1.13%
Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the login_username parameter.