CVE-2022-26974barcocontrol_room_management_suite
EPSS score0.57%
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a file upload mechanism. Lack of input sanitization in the upload mechanism leads to reflected XSS.CVE-2022-26976barcocontrol_room_management_suiteEPSS score0.46%
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS.CVE-2022-26978barcocontrol_room_management_suiteEPSS score0.57%
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS.CVE-2022-26973barcocontrol_room_management_suiteEPSS score0.78%
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. By tweaking the license file name, the returned error message exposes internal directory path details.CVE-2022-26977barcocontrol_room_management_suiteEPSS score0.57%
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS.CVE-2022-26975barcocontrol_room_management_suiteEPSS score1.03%
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication.CVE-2017-9377barcoclickshare_csc-1_firmware+1EPSS score4.35%
A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product's web API can exploit this vulnerability to completely compromise the vulnerable device.CVE-2017-12460barcoclickshare_csc-1_firmware+1EPSS score0.64%
An issue was discovered in Barco ClickShare CSM-1 firmware before v1.7.0.3 and CSC-1 firmware before v1.10.0.10. An authenticated user can manage the wallpaper collection in the webUI to be shown as background on the ClickShare product. By uploading a wallpaper with a specially crafted name, an HTML injection can be triggered as special characters are not neutralized before output.CVE-2019-18825barcoclickshare_cs-100_huddle_firmware+1EPSS score0.60%
Barco ClickShare Huddle CS-100 devices before 1.9.0 and CSE-200 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Base Unit implements encryption at rest using encryption keys which are shared across all ClickShare Base Units of models CS-100 & CSE-200.CVE-2019-18832barcoclickshare_button_r9861500d01_firmwareEPSS score0.43%
Barco ClickShare Button R9861500D01 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Button implements encryption at rest which uses a one-time programmable (OTP) AES encryption key. This key is shared across all ClickShare Buttons of model R9861500D01.CVE-2019-18831barcoclickshare_cs-100_firmware+2EPSS score0.57%
Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information Exposure. The encrypted ClickShare Button firmware contains the private key of a test device-certificate.CVE-2019-18829barcoclickshare_button_r9861500d01_firmwareEPSS score0.33%
Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The Barco signed 'Clickshare_For_Windows.exe' binary on the ClickShare Button (R9861500D01) loads a number of DLL files dynamically without verifying their integrity.CVE-2019-18826barcoclickshare_cs-100_firmware+2EPSS score0.68%
Barco ClickShare Button R9861500D01 devices before 1.9.0 have Improper Following of a Certificate's Chain of Trust. The embedded 'dongle_bridge' program used to expose the functionalities of the ClickShare Button to a USB host, does not properly validate the whole certificate chain.CVE-2019-18827barcoclickshare_cs-100_firmware+2EPSS score1.35%
On Barco ClickShare Button R9861500D01 devices (before firmware version 1.9.0) JTAG access is disabled after ROM code execution. This means that JTAG access is possible when the system is running code from ROM before handing control over to embedded firmware.CVE-2019-18833barcoclickshare_button_r9861500d01_firmwareEPSS score0.36%
Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information exposure (issue 2 of 2).. The encryption key of the media content which is shared between a ClickShare Button and a ClickShare Base Unit is randomly generated for each new session and communicated over a TLS connection. An attacker who is able to perform a Man-in-the-Middle attack between the TLS connection, is able to obtain the encryption key.CVE-2019-18828barcoclickshare_cs-100_firmware+2EPSS score0.39%
Barco ClickShare Button R9861500D01 devices before 1.9.0 have Insufficiently Protected Credentials. The root account (present for access via debug interfaces, which are by default not enabled on production devices) of the embedded Linux on the ClickShare Button is using a weak password.CVE-2019-18830barcoclickshare_cs-100_firmware+2EPSS score4.34%
Barco ClickShare Button R9861500D01 devices before 1.9.0 allow OS Command Injection. The embedded 'dongle_bridge' program used to expose the functionalities of the ClickShare Button to a USB host, is vulnerable to OS command injection vulnerabilities. These vulnerabilities could lead to code execution on the ClickShare Button with the privileges of the user 'nobody'.CVE-2019-18824barcoclickshare_button_r9861500d01_firmwareEPSS score0.34%
Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The ClickShare Button does not verify the integrity of the mutable content on the UBIFS partition before being used.CVE-2019-3929barcowepresent_wipg-1000p_firmware+12KEVEPSS score98.95%
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.CVE-2019-3930barcowepresent_wipg-1000p_firmware+12EPSS score6.96%
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.