Crestron vulnerabilities, page 2

47 vulnerabilities

Known vulnerabilities in Crestron products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 29 products.

7.5CVE-2020-16839crestrondm-nvx-dir-160_firmware+2
EPSS score
1.18%
On Crestron DM-NVX-DIR, DM-NVX-DIR80, and DM-NVX-ENT devices before the DM-XIO/1-0-3-802 patch, the password can be changed by sending an unauthenticated WebSocket request.
8.8CVE-2022-40298crestronairmedia
EPSS score
0.71%
Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell.
8.8CVE-2022-34100crestronairmedia
EPSS score
1.19%
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installation of a trusted service executable and change permissions on that file structure during a repair operation.
7.8CVE-2022-34101crestronairmedia
EPSS score
0.37%
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can place a malicious DLL in a certain path to execute code and preform a privilege escalation attack.
8.8CVE-2022-34102crestronairmedia
EPSS score
1.04%
Insufficient access control vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can pause the uninstallation of an executable to gain a SYSTEM level command prompt.
10CVE-2022-23178crestronhd-md4x2-4k-e_firmware
EPSS score
75.16%
An issue was discovered on Crestron HD-MD4X2-4K-E 1.0.0.2159 devices. When the administrative web interface of the HDMI switcher is accessed unauthenticated, user credentials are disclosed that are valid to authenticate to the web interface. Specifically, aj.html sends a JSON document with uname and upassword fields.
7.2CVE-2017-16709crestronairmedia_am-100_firmware+1
EPSS score
71.96%
Crestron Airmedia AM-100 devices with firmware before 1.6.0 and AM-101 devices with firmware before 2.7.0 allows remote authenticated administrators to execute arbitrary code via unspecified vectors.
4.8CVE-2017-16710crestronairmedia_am-100_firmware+1
EPSS score
0.61%
Cross-site scripting (XSS) vulnerability in Crestron Airmedia AM-100 devices with firmware before 1.6.0 and AM-101 devices with firmware before 2.7.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
10CVE-2019-18184crestrondmc-stro_firmware
EPSS score
8.15%
Crestron DMC-STRO 1.0 devices allow remote command execution as root via shell metacharacters to the ping function.
5.3CVE-2019-3934crestronam-100_firmware+2
EPSS score
7.73%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code.
7.8CVE-2019-3938crestronam-100_firmware+2
EPSS score
0.26%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.
9.8CVE-2019-3939crestronam-100_firmware+2
EPSS score
2.76%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
9.1CVE-2019-3935crestronam-100_firmware+2
EPSS score
3.33%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows.
5.3CVE-2019-3928crestronam-100_firmware+2
EPSS score
1.77%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter.
9CVE-2019-3931crestronam-100_firmware+2
EPSS score
5.77%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root.
9.8CVE-2019-3932crestronam-100_firmware+2
EPSS score
36.33%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
9.8CVE-2019-3927crestronam-100_firmware+2
EPSS score
2.17%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user's password and gain access to restricted areas on the HTTP interface.
7.5CVE-2019-3936crestronam-100_firmware+2
EPSS score
2.14%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a "stopped" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow.
9.1CVE-2019-3910crestronairmedia_am-100_firmware
EPSS score
8.56%
Crestron AM-100 before firmware version 1.6.0.2 contains an authentication bypass in the web interface's return.cgi script. Unauthenticated remote users can use the bypass to access some administrator functionality such as configuring update sources and rebooting the device.
5.3CVE-2019-3933crestronam-100_firmware+2
EPSS score
5.95%
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.