CVE-2025-27955philipsclinical_collaboration_platform
EPSS score0.34%
Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code.CVE-2025-27954philipsclinical_collaboration_platformEPSS score0.36%
An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx.CVE-2025-3425philipsintellispace_portalEPSS score0.33%
The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the deserialization vulnerability. After analyzing the configuration files, we observed that the server had set the TypeFilterLevel to Full which is dangerous as it can potentially lead to remote code execution using deserialization. This issue affects IntelliSpace Portal: 12 and prior.CVE-2025-3426philipsadvanced visualization workspace+1EPSS score0.16%
We observed that Intellispace Portal binaries doesn’t have any protection mechanisms to prevent reverse engineering. Specifically, the app’s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.
Utilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.
This issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15.CVE-2025-3424philipsintellispace_portalEPSS score0.24%
The IntelliSpace portal application utilizes .NET
Remoting for its functionality. The vulnerability arises from the exploitation
of port 755 through the "Object Marshalling" technique, which allows
an attacker to read internal files without any authentication. This is possible
by crafting specific .NET Remoting URLs derived from information enumerated in
the client-side configuration files.
This issue affects IntelliSpace Portal: 12 and prior.CVE-2020-16212philipspatient_information_center_ix+1EPSS score0.37%
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.CVE-2020-16220philipspatient_information_center_ix+2EPSS score0.28%
In Patient Information Center iX (PICiX) Versions C.02, C.03,
PerformanceBridge Focal Point Version A.01, the product receives input
that is expected to be well-formed (i.e., to comply with a certain
syntax) but it does not validate or incorrectly validates that the input
complies with the syntax, causing the certificate enrollment service to
crash. It does not impact monitoring but prevents new devices from
enrolling.CVE-2020-16247philipsclinical_collaboration_platformEPSS score0.36%
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.CVE-2020-16239philipssuresigns_vs4_firmwareEPSS score1.00%
When an actor claims to have a given identity,
Philips SureSigns VS4, A.07.107 and prior
does not prove or insufficiently proves the claim is correct.CVE-2020-16218philipspatient_information_center_ix+1EPSS score0.65%
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software does not neutralize or incorrectly neutralizes
user-controllable input before it is placed in output that is then used
as a webpage and served to other users. Successful exploitation could
lead to unauthorized access to patient data via a read-only web
application.CVE-2020-16198philipsclinical_collaboration_platformEPSS score0.56%
When an attacker claims to have a given identity,
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not prove or insufficiently proves the claim is correct.CVE-2020-16241philipssuresigns_vs4_firmwareEPSS score0.26%
Philips SureSigns VS4, A.07.107 and prior
does not restrict or incorrectly restricts access to a resource from an unauthorized actor.CVE-2020-16222philipspatient_information_center_ix+2EPSS score0.55%
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and
PerformanceBridge Focal Point Version A.01, when an actor claims to have
a given identity, the software does not prove or insufficiently proves
the claim is correct.CVE-2020-16216philipsintellivue+14EPSS score0.70%
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the product receives input or data but does not validate or incorrectly
validates that the input has the properties required to process the data
safely and correctly, which can induce a denial-of-service condition
through a system restart.CVE-2020-16224philipspatient_information_center_ix+1EPSS score0.59%
In Patient Information Center iX (PICiX) Versions C.02, C.03, the
software parses a formatted message or structure but does not handle or
incorrectly handles a length field that is inconsistent with the actual
length of the associated data, causing the application on the
surveillance station to restart.CVE-2020-16200philipsclinical_collaboration_platformEPSS score0.62%
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not properly control the allocation and maintenance of a limited
resource, thereby enabling an attacker to influence the amount of
resources consumed, eventually leading to the exhaustion of available
resources.CVE-2020-16214philipspatient_information_center_ix+1EPSS score0.59%
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software saves user-provided information into a comma-separated value
(CSV) file, but it does not neutralize or incorrectly neutralizes
special elements that could be interpreted as a command when the file is
opened by spreadsheet software.CVE-2020-16237philipssuresigns_vs4_firmwareEPSS score0.34%
Philips SureSigns VS4, A.07.107 and prior receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.CVE-2020-16228philipsintellivue_mp2-mp90_firmware+14EPSS score0.37%
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate, which may cause it to use a compromised
certificate.CVE-2020-11617philipsdtr3502bfta_dvb-t2_firmware+1EPSS score0.42%
The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client.