Rockwellautomation Connected Components Workbench vulnerabilities
6 vulnerabilities
Known vulnerabilities in Rockwellautomation Connected Components Workbench, newest first, with CVSS severity, EPSS, KEV listings, ransomware use and the affected versions.
HighCVE-2021-27471rockwell automation · connected components workbench +1 moreRockwell Automation Connected Components Workbench Path TraversalThe parsing mechanism that processes certain file types does not provide input sanitization for file paths. This may allow an attacker to craft malicious files that, when opened by Rockwell Automation Connected Components Workbench v12.00.00 and prior, can traverse the file system. If successfully exploited, an attacker could overwrite existing files and create additional files with the same permissions of the Connected Components Workbench software. User interaction is required for this exploit to be successful.EPSS2.86%HighCVE-2021-27475rockwell automation · connected components workbench +1 moreRockwell Automation Connected Components Workbench Deserialization of Untrusted DataThis vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.EPSS2.99%HighCVE-2021-27473rockwell automation · connected components workbench +1 moreRockwell Automation Connected Components Workbench Improper Input ValidationThis type of vulnerability is also commonly referred to as a Zip Slip. A local, authenticated attacker can create a malicious .ccwarc archive file that, when opened by Connected Components Workbench, will allow the attacker to gain the privileges of the software. If the software is running at SYSTEM level, the attacker will gain admin level privileges. User interaction is required for this exploit to be successful.EPSS0.78%HighCVE-2014-5424rockwellautomation · connected_components_workbenchrockwellautomation connected_components_workbenchRockwell Automation Connected Components Workbench (CCW) before 7.00.00 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via an invalid property value to an ActiveX control that was built with an outdated compiler.EPSS11.00%MediumCVE-2022-1018rockwell automation · connected component workbench +5 moreICSA-22-088-01 Rockwell Automation ISaGRAFWhen opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality.EPSS2.15%HighCVE-2017-5176rockwellautomation · connected_components_workbenchrockwellautomation connected_components_workbenchA DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges.EPSS0.52%