Schneider Electric Ecostruxure Geo Scada Expert 2020 vulnerabilities

5 vulnerabilities

Known vulnerabilities in Schneider Electric Ecostruxure Geo Scada Expert 2020, newest first, with CVSS severity, EPSS, KEV listings, ransomware use and the affected versions.

6.7CVE-2021-22741schneider-electricecostruxure_geo_scada_expert_2020
EPSS score
0.17%
Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions), and EcoStruxure Geo SCADA Expert 2020 (V83.7742.1 and prior), which could cause the revealing of account credentials when server database files are available. Exposure of these files to an attacker can make the system vulnerable to password decryption attacks. Note that “.sde” configuration export files do not contain user account password hashes.
7.8CVE-2020-28219schneider-electricecostruxure_geo_scada_expert_2019+1
EPSS score
0.31%
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.
5.3CVE-2023-0595schneider electricclearscada+6
EPSS score
0.42%
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)
7.5CVE-2023-22611schneider electricecostruxure geo scada expert 2019 - 2021 (formerly known as clearscada)+3
EPSS score
0.57%
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
9.1CVE-2023-22610schneider electricecostruxure geo scada expert 2019 - 2021 (formerly known as clearscada)+3
EPSS score
0.57%
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.