CVE-2020-7493schneider-electricecostruxure_operator_terminal_expert
EPSS score1.14%
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.CVE-2020-7494schneider-electricecostruxure_operator_terminal_expertEPSS score1.35%
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.CVE-2020-7495schneider-electricecostruxure_operator_terminal_expertEPSS score0.88%
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access outside of expected path folder when opening the project file.CVE-2020-7497schneider-electricecostruxure_operator_terminal_expertEPSS score2.29%
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts.CVE-2020-28221schneider-electricecostruxure_operator_terminal_expert+1EPSS score2.14%
A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI.CVE-2022-41668schneider electricecostruxure operator terminal expert+3EPSS score0.21%
A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).CVE-2022-41667schneider electricecostruxure operator terminal expert+3EPSS score0.23%
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).CVE-2022-41670schneider electricecostruxure operator terminal expert+3EPSS score0.20%
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).CVE-2022-41671schneider electricecostruxure operator terminal expert+3EPSS score0.27%
A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).CVE-2022-41666schneider electricecostruxure operator terminal expert+3EPSS score0.14%
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).CVE-2022-41669schneider electricecostruxure operator terminal expert+3EPSS score0.12%
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).CVE-2023-1049schneider electricecostruxure™ operator terminal expert+3EPSS score0.60%
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
could cause execution of malicious code when an unsuspicious user loads a project file from the
local filesystem into the HMI.