CVE-2018-7797schneider-electricecostruxure_energy_expert+2
EPSS score0.76%
A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site.CVE-2021-22826schneider-electricecostruxure_power_monitoring_expertEPSS score1.20%
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versionsCVE-2021-22827schneider-electricecostruxure_power_monitoring_expertEPSS score1.20%
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versionsCVE-2025-11739schneider electricecostruxure™ power monitoring expert (pme)+3EPSS score0.19%
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.CVE-2020-7547schneider-electricecostruxure_energy_expert+4EPSS score1.31%
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.CVE-2020-7545schneider-electricecostruxure_energy_expert+4EPSS score2.08%
A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.CVE-2020-7546schneider-electricecostruxure_energy_expert+4EPSS score0.63%
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.CVE-2022-22727schneider-electricecostruxure_power_monitoring_expertEPSS score1.23%
A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)CVE-2022-22726schneider-electricecostruxure_power_monitoring_expertEPSS score0.77%
A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)CVE-2022-22804schneider-electricecostruxure_power_monitoring_expertEPSS score0.45%
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)CVE-2023-5986schneider electricecostruxure power monitoring expert (pme)+3EPSS score0.45%
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input
attackers can cause the software’s web application to redirect to the chosen domain after a
successful login is performed.CVE-2023-5987schneider electricecostruxure power monitoring expert (pme)+3EPSS score0.41%
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)
vulnerability that could cause a vulnerability leading to a cross site scripting condition where
attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing
the injected payload.CVE-2023-28003schneider electricecostruxure power monitoring expert+1EPSS score0.32%
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to
maintain unauthorized access over a hijacked session in PME after the legitimate user has
signed out of their account.