Schneider Electric vulnerabilities

320 vulnerabilities

Known vulnerabilities in Schneider Electric products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 306 products.

Products

47 of 306
8.6CVE-2026-102250schneider electricsage rtu 1410+5
EPSS score
0.15%
CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could result in control over the device.
7.2CVE-2018-7522schneider electrictriconex tricon+1
EPSS score
0.42%
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.
9.3CVE-2018-8872schneider electrictriconex tricon+1
EPSS score
2.20%
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
9.3CVE-2013-0662schneider_electricsomachine+12
EPSS score
22.22%
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
8.8CVE-2021-22783schneider electricritto wiser door
EPSS score
0.37%
A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)
9.8CVE-2021-22794schneider electricstruxureware data center expert+1
EPSS score
2.22%
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
9.3CVE-2021-22797schneider electricecostruxure control expert+5
EPSS score
26.10%
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
9.8CVE-2021-22795schneider electricstruxureware data center expert+1
EPSS score
3.12%
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
7.8CVE-2021-22716schneider electricc-bus toolkit+1
EPSS score
0.77%
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
7.5CVE-2021-22786schneider electriclegacy modicon quantum+46
EPSS score
0.63%
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)
7.3CVE-2015-1014schneider electricofs v3.5+1
EPSS score
0.46%
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
4.9CVE-2025-54927schneider electricecostruxure™ power monitoring expert (pme)+1
EPSS score
0.60%
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system.
7.2CVE-2025-54926schneider electricecostruxure™ power monitoring expert (pme)+1
EPSS score
0.91%
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.
7.5CVE-2025-54925schneider electricecostruxure™ power monitoring expert (pme)+1
EPSS score
0.45%
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.
8.7CVE-2025-54923schneider electricecostruxure™ power monitoring expert (pme)+1
EPSS score
0.68%
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization.
7.5CVE-2025-54924schneider electricecostruxure™ power monitoring expert (pme)+1
EPSS score
0.45%
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.
8.2CVE-2025-2222schneider electricconnexium network manager
EPSS score
0.30%
CWE-552: Files or Directories Accessible to External Parties vulnerability over https exists that could leak information and potential privilege escalation following man in the middle attack.
6CVE-2025-2002schneider electricecostruxure panel server
EPSS score
0.17%
CWE-532: Insertion of Sensitive Information into Log Files vulnerability exists that could cause the disclosure of FTP server credentials when the FTP server is deployed, and the device is placed in debug mode by an administrative user and the debug files are exported from the device.
4.2CVE-2025-2440schneider electrictrio q licensed data radio
EPSS score
0.19%
CWE-922: Insecure Storage of Sensitive Information vulnerability exists that could potentially lead to unauthorized access of confidential data when a malicious user, having physical access and advanced information on the file system, sets the radio in factory default mode.
6.8CVE-2025-2442schneider electrictrio q licensed data radio
EPSS score
0.25%
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.