Schneider Electric vulnerabilities
320 vulnerabilities
Known vulnerabilities in Schneider Electric products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 306 products.
Products
47 of 306- Struxureware Data Center Expert15 vulnerabilities
- Ecostruxure Control Expert12 vulnerabilities
- Modicon M340 CPU (Part Numbers Bmxp34*)12 vulnerabilities
- Powerchute™ Serial Shutdown11 vulnerabilities
- IGSS Data Server (Igssdataserver.Exe)10 vulnerabilities
- Ecostruxure Process Expert9 vulnerabilities
- IGSS Dashboard (Dashboard.Exe)9 vulnerabilities
- Custom Reports (Rms16.Dll)8 vulnerabilities
- IGSS Data Server(Igssdataserver.Exe)8 vulnerabilities
- Ecostruxure™ IT Data Center Expert7 vulnerabilities
- Modicon Controllers M241/M2517 vulnerabilities
- Modicon M580 CPU Safety (Part Numbers Bmep58*S And Bmeh58*S)7 vulnerabilities
- Modicon Momentum Unity M1E Processor (171Cbu*)7 vulnerabilities
- OPC UA Modicon Communication Module7 vulnerabilities
- Pro Face BLUE7 vulnerabilities
- X80 Advanced RTU Communication Module7 vulnerabilities
- Data Center Expert6 vulnerabilities
- Ecostruxure Operator Terminal Expert6 vulnerabilities
- Ecostruxure™ Power Monitoring Expert (Pme)6 vulnerabilities
- Ecostruxure™ Power Operation (Epo) Advanced Reporting And Dashboards Module6 vulnerabilities
- Modicon M580 CPU (Part Numbers Bmep* And Bmeh*)6 vulnerabilities
- Sage 14106 vulnerabilities
- Sage 14306 vulnerabilities
- Sage 14506 vulnerabilities
- Sage 24006 vulnerabilities
- Sage 3030 Magnum6 vulnerabilities
- Sage 44006 vulnerabilities
- Wiser Smart6 vulnerabilities
- Clearscada5 vulnerabilities
- Modicon Controllers M258 / Lmc0585 vulnerabilities
- Modicon MC80 (Bmkc80)5 vulnerabilities
- Wonderware Information Server Portal5 vulnerabilities
- APC Easy UPS Online Monitoring Software4 vulnerabilities
- ASCO 5310 Single Channel Remote Annunciator4 vulnerabilities
- ASCO 5350 Eight Channel Remote Annunciator4 vulnerabilities
- Easergy P54 vulnerabilities
- Ecostruxure Power Commission4 vulnerabilities
- Evlink Wallbox4 vulnerabilities
- Modicon MC80 (Part Numbers Bmkc80)4 vulnerabilities
- Proclima4 vulnerabilities
- Scada Expert Clearscada4 vulnerabilities
- Schneider Electric Easy UPS Online Monitoring Software4 vulnerabilities
- APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)3 vulnerabilities
- C Bus Toolkit3 vulnerabilities
- Conext™ Combox3 vulnerabilities
- Easergy Studio3 vulnerabilities
- Easylogic T150 (Formerly Saitel DR) Remote Terminal Unit & Controller3 vulnerabilities
CVE-2026-102250schneider electricsage rtu 1410+5
EPSS score0.15%
CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could result in control over the device.CVE-2018-7522schneider electrictriconex tricon+1EPSS score0.42%
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.CVE-2018-8872schneider electrictriconex tricon+1EPSS score2.20%
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.CVE-2013-0662schneider_electricsomachine+12EPSS score22.22%
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.CVE-2021-22783schneider electricritto wiser doorEPSS score0.37%
A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)CVE-2021-22794schneider electricstruxureware data center expert+1EPSS score2.22%
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)CVE-2021-22797schneider electricecostruxure control expert+5EPSS score26.10%
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)CVE-2021-22795schneider electricstruxureware data center expert+1EPSS score3.12%
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)CVE-2021-22716schneider electricc-bus toolkit+1EPSS score0.77%
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)CVE-2021-22786schneider electriclegacy modicon quantum+46EPSS score0.63%
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)CVE-2015-1014schneider electricofs v3.5+1EPSS score0.46%
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.CVE-2025-54927schneider electricecostruxure™ power monitoring expert (pme)+1EPSS score0.60%
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system.CVE-2025-54926schneider electricecostruxure™ power monitoring expert (pme)+1EPSS score0.91%
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.CVE-2025-54925schneider electricecostruxure™ power monitoring expert (pme)+1EPSS score0.45%
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.CVE-2025-54923schneider electricecostruxure™ power monitoring expert (pme)+1EPSS score0.68%
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization.CVE-2025-54924schneider electricecostruxure™ power monitoring expert (pme)+1EPSS score0.45%
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.CVE-2025-2222schneider electricconnexium network managerEPSS score0.30%
CWE-552: Files or Directories Accessible to External Parties vulnerability over https exists that could leak
information and potential privilege escalation following man in the middle attack.CVE-2025-2002schneider electricecostruxure panel serverEPSS score0.17%
CWE-532: Insertion of Sensitive Information into Log Files vulnerability exists that could cause the disclosure
of FTP server credentials when the FTP server is deployed, and the device is placed in debug mode by an
administrative user and the debug files are exported from the device.CVE-2025-2440schneider electrictrio q licensed data radioEPSS score0.19%
CWE-922: Insecure Storage of Sensitive Information vulnerability exists that could potentially lead to unauthorized
access of confidential data when a malicious user, having physical access and advanced information on the file
system, sets the radio in factory default mode.CVE-2025-2442schneider electrictrio q licensed data radioEPSS score0.25%
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to
unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious
user, having physical access, sets the radio to the factory default mode.