Siemens Sicam A8000 vulnerabilities
2 vulnerabilities
Known vulnerabilities in Siemens Sicam A8000, newest first, with CVSS severity, EPSS, KEV listings, ransomware use and the affected versions.
CVE-2020-15781siemens agsicam web firmware for sicam a8000 rtus+1
EPSS score1.00%
A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application.CVE-2024-34057siemenssicam_a8000_firmware+4EPSS score0.44%
Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service.