Siemens Siplus ET 200Sp IM 155 6 PN ST vulnerabilities

7 vulnerabilities

Known vulnerabilities in Siemens Siplus ET 200Sp IM 155 6 PN ST, newest first, with CVSS severity, EPSS, KEV listings, ransomware use and the affected versions.

7.1CVE-2017-2681siemensdevelopment/evaluation kits for profinet io: dk standard ethernet controller+174
EPSS score
0.91%
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
7.1CVE-2017-2680siemensdevelopment/evaluation kits for profinet io: dk standard ethernet controller+200
EPSS score
1.15%
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
8.7CVE-2017-12741siemensdevelopment/evaluation kits for profinet io: dk standard ethernet controller+118
EPSS score
3.31%
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
6.9CVE-2024-23814siemenssidoor_atd430w_firmware+136
EPSS score
0.62%
The integrated ICMP service of the network stack of affected devices can be forced to exhaust its available memory resources when receiving specially crafted messages targeting IP fragment re-assembly. This could allow an unauthenticated remote attacker to cause a temporary denial of service condition of the ICMP service, other communication services are not affected. Affected devices will resume normal operation after the attack terminates.
7.8CVE-2019-13946siemensdevelopment/evaluation kits for profinet io: dk standard ethernet controller+190
EPSS score
1.46%
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
7.5CVE-2019-10936siemensdevelopment/evaluation kits for profinet io: dk standard ethernet controller+139
EPSS score
2.07%
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
7.5CVE-2019-10923siemenscp1604_firmware+110
EPSS score
1.40%
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.