Siemens AG vulnerabilities
129 vulnerabilities
Known vulnerabilities in Siemens AG products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 183 products.
Products
50 of 183- Sicam MMU9 vulnerabilities
- Sicam SGU9 vulnerabilities
- Sicam T9 vulnerabilities
- Sinumerik 808D V4.7, Sinumerik 808D V4.8, Sinumerik 828D V4.7, Sinumerik 840D Sl V4.7, Sinumerik 840D Sl V4.87 vulnerabilities
- Scalance M8756 vulnerabilities
- Siclock Tc100, Siclock Tc4006 vulnerabilities
- Simatic PCS 7 V8.0 And Earlier5 vulnerabilities
- Simatic PCS 7 V8.15 vulnerabilities
- Simatic PCS 7 V8.25 vulnerabilities
- Simatic Wincc V7.2 And Earlier5 vulnerabilities
- Simatic Wincc V7.35 vulnerabilities
- Simatic Wincc V7.45 vulnerabilities
- En100 Ethernet Module DNP3 Variant4 vulnerabilities
- En100 Ethernet Module IEC 61850 Variant4 vulnerabilities
- En100 Ethernet Module Modbus TCP Variant4 vulnerabilities
- En100 Ethernet Module Profinet IO Variant4 vulnerabilities
- Simatic PCS 7 V9.04 vulnerabilities
- Simatic Wincc Runtime Advanced4 vulnerabilities
- Simatic Wincc Runtime Professional V134 vulnerabilities
- Simatic Wincc Runtime Professional V144 vulnerabilities
- Simatic Wincc Runtime Professional V154 vulnerabilities
- Simatic Wincc (TIA Portal) V134 vulnerabilities
- Simatic Wincc (TIA Portal) V144 vulnerabilities
- Simatic Wincc V7.54 vulnerabilities
- Sinema Remote Connect Server4 vulnerabilities
- En100 Ethernet Module Iec104 Variant3 vulnerabilities
- Polarion3 vulnerabilities
- Simatic HMI Classic Devices (Tp/Mp/Op/Mp Mobile Panel)3 vulnerabilities
- Simatic HMI Comfort Outdoor Panels 7" & 15"3 vulnerabilities
- Simatic HMI Comfort Panels 4" 22"3 vulnerabilities
- Simatic HMI KTP Mobile Panels Ktp400F, Ktp700, Ktp700F, Ktp900 Und Ktp900F3 vulnerabilities
- Simatic RTLS Locating Manager3 vulnerabilities
- Simatic S7 300 CPU Family (Incl. Related Et200 Cpus And Siplus Variants)3 vulnerabilities
- Simatic Wincc Runtime Professional3 vulnerabilities
- Simatic Wincc (TIA Portal)3 vulnerabilities
- Simatic Wincc (TIA Portal) V153 vulnerabilities
- Sinumerik 828D V4.7, Sinumerik 840D Sl V4.7, Sinumerik 840D Sl V4.83 vulnerabilities
- Siveillance VMS 2017 R23 vulnerabilities
- Siveillance VMS 2018 R13 vulnerabilities
- Siveillance VMS 2018 R23 vulnerabilities
- Siveillance VMS 2018 R33 vulnerabilities
- Siveillance VMS 2019 R13 vulnerabilities
- Telecontrol Server Basic3 vulnerabilities
- XHQ3 vulnerabilities
- All Other Siprotec 5 Device Types With CPU Variants Cp300 And Cp100 And The Respective Ethernet Communication Modules2 vulnerabilities
- Automation License Manager 52 vulnerabilities
- Digsi 5 Engineering Software2 vulnerabilities
- Firmware Variant DNP3 TCP For En100 Ethernet Module2 vulnerabilities
- Firmware Variant IEC 61850 For En100 Ethernet Module2 vulnerabilities
- Firmware Variant Iec104 For En100 Ethernet Module2 vulnerabilities
CVE-2018-16555siemens agscalance s602, scalance s612, scalance s623, scalance s627-2m+4
EPSS score0.69%
A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.CVE-2018-13806siemens agsiemens td keypad designerEPSS score1.44%
A vulnerability has been identified in SIEMENS TD Keypad Designer (All versions). A DLL hijacking vulnerability exists in all versions of SIEMENS TD Keypad Designer which could allow an attacker to execute code with the permission of the user running TD Designer. The attacker must have write access to the directory containing the TD project file in order to exploit the vulnerability. A legitimate user with higher privileges than the attacker must open the TD project in order for this vulnerability to be exploited. At the time of advisory publication no public exploitation of this security vulnerability was known.CVE-2018-13798siemens agsicam a8000 cp-8000, sicam a8000 cp-802x, sicam a8000 cp-8050+5EPSS score1.99%
A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions < V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public.CVE-2018-13811siemens agsimatic step 7 (tia portal)+1EPSS score0.24%
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known.CVE-2018-13799siemens agsimatic wincc oa v3.14 and prior+1EPSS score2.25%
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.CVE-2018-13815siemens agsimatic s7-1200, simatic s7-1500+2EPSS score1.80%
A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.CVE-2018-13802siemens agrox ii+1EPSS score3.57%
A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device.CVE-2018-13805siemens agsimatic et 200sp open controller+5EPSS score1.53%
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software Controller (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 incl. F (All versions >= V2.0 and < V2.5). An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. An attacker could use this vulnerability to compromise availability of the network connectivity. At the time of advisory publication no public exploitation of this vulnerability was known.CVE-2018-13800siemens agsimatic s7-1200 cpu family version 4+1EPSS score0.63%
A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 (All versions < V4.2.3). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify parts of the device configuration.CVE-2018-13816siemens agtim 1531 irc+1EPSS score2.80%
A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known.CVE-2018-13807siemens agscalance x300, scalance x408, scalance x414+3EPSS score4.18%
A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.CVE-2018-13801siemens agrox ii+1EPSS score2.68%
A vulnerability has been identified in ROX II (All versions < V2.12.1). An attacker with network access to port 22/tcp and valid low-privileged user credentials for the target device could perform a privilege escalation and gain root privileges. Successful exploitation requires user privileges of a low-privileged user but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system.CVE-2018-11447siemens agscalance m875+1EPSS score0.58%
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.CVE-2018-11466siemens agsinumerik 808d v4.7, sinumerik 808d v4.8, sinumerik 828d v4.7, sinumerik 840d sl v4.7, sinumerik 840d sl v4.8+3EPSS score4.08%
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was knownCVE-2018-11456siemens agautomation license manager 5+1EPSS score1.26%
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.CVE-2018-11452siemens agfirmware variant dnp3 tcp for en100 ethernet module+12EPSS score2.39%
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.CVE-2018-11464siemens agsinumerik 828d v4.7, sinumerik 840d sl v4.7, sinumerik 840d sl v4.8+2EPSS score1.86%
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.CVE-2018-11463siemens agsinumerik 808d v4.7, sinumerik 808d v4.8, sinumerik 828d v4.7, sinumerik 840d sl v4.7, sinumerik 840d sl v4.8+3EPSS score0.46%
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.CVE-2018-11461siemens agsinumerik 808d v4.7, sinumerik 808d v4.8, sinumerik 828d v4.7, sinumerik 840d sl v4.7, sinumerik 840d sl v4.8+3EPSS score0.35%
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.CVE-2018-11458siemens agsinumerik 828d v4.7, sinumerik 840d sl v4.7, sinumerik 840d sl v4.8+3EPSS score4.59%
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.