Tenda Ac5 vulnerabilities
41 vulnerabilities
Known vulnerabilities in Tenda Ac5, newest first, with CVSS severity, EPSS, KEV listings, ransomware use and the affected versions.
CVE-2021-44971tendaac15_firmware+1
EPSS score2.10%
Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE.CVE-2021-3186tendaac5_firmwareEPSS score2.54%
A Stored Cross-site scripting (XSS) vulnerability in /main.html Wifi Settings in Tenda AC5 AC1200 version V15.03.06.47_multi allows remote attackers to inject arbitrary web script or HTML via the Wifi Name parameter.CVE-2025-5863tendaac5_firmwareEPSS score1.01%
A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.CVE-2025-5794tendaac5_firmwareEPSS score0.98%
A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.CVE-2025-5795tendaac5_firmwareEPSS score0.98%
A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.CVE-2025-6886tendaac5_firmwareEPSS score0.96%
A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.CVE-2025-6887tendaac5_firmwareEPSS score0.99%
A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.CVE-2026-105778tendaac5_firmwareEPSS score0.48%
A vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.CVE-2026-4903tendaac5_firmwareEPSS score1.01%
A flaw has been found in Tenda AC5 15.03.06.47. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. This manipulation of the argument PPPOEPassword causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used.CVE-2026-4904tendaac5_firmwareEPSS score1.01%
A vulnerability has been found in Tenda AC5 15.03.06.47. This issue affects the function formSetCfm of the file /goform/setcfm of the component POST Request Handler. Such manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.CVE-2026-4906tendaac5_firmwareEPSS score1.01%
A vulnerability was determined in Tenda AC5 15.03.06.47. The affected element is the function decodePwd of the file /goform/WizardHandle of the component POST Request Handler. Executing a manipulation of the argument WANT/WANS can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.CVE-2026-4902tendaac5_firmwareEPSS score1.01%
A vulnerability was detected in Tenda AC5 15.03.06.47. This affects the function fromAddressNat of the file /goform/addressNat of the component POST Request Handler. The manipulation of the argument page results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.CVE-2026-4905tendaac5_firmwareEPSS score1.01%
A vulnerability was found in Tenda AC5 15.03.06.47. Impacted is the function formWifiWpsOOB of the file /goform/WifiWpsOOB of the component POST Request Handler. Performing a manipulation of the argument index results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.CVE-2023-41563tendaac5_firmware+1EPSS score0.84%
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.CVE-2023-41556tendaac5_firmware+2EPSS score1.12%
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.CVE-2023-41557tendaac5_firmware+1EPSS score0.84%
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.CVE-2023-41553tendaac5_firmware+1EPSS score0.84%
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.CVE-2023-41559tendaac5_firmware+2EPSS score0.84%
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.CVE-2023-41562tendaac5_firmware+2EPSS score0.84%
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.CVE-2023-41561tendaac5_firmware+1EPSS score0.84%
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.