Wago vulnerabilities
146 vulnerabilities
Known vulnerabilities in Wago products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 406 products.
Products
50 of 406- Pfc20040 vulnerabilities
- 750 820227 vulnerabilities
- 750 88127 vulnerabilities
- 750 83126 vulnerabilities
- 750 88026 vulnerabilities
- 750 88926 vulnerabilities
- 750 85225 vulnerabilities
- 750 82324 vulnerabilities
- 750 83224 vulnerabilities
- 750 86224 vulnerabilities
- 750 88224 vulnerabilities
- 750 88524 vulnerabilities
- 750 89124 vulnerabilities
- 750 820623 vulnerabilities
- 750 820723 vulnerabilities
- 750 821023 vulnerabilities
- 750 821123 vulnerabilities
- 750 821223 vulnerabilities
- 750 821323 vulnerabilities
- 750 821423 vulnerabilities
- 750 821623 vulnerabilities
- 750 821723 vulnerabilities
- 750 82923 vulnerabilities
- 750 89023 vulnerabilities
- 750 820322 vulnerabilities
- 750 820422 vulnerabilities
- 750 820822 vulnerabilities
- 750 89322 vulnerabilities
- Cc100 0751 9X0113 vulnerabilities
- Pfc10013 vulnerabilities
- Pfc100 G2 0750 811X Xxxx Xxxx13 vulnerabilities
- WAGO Pfc20013 vulnerabilities
- Edge Controller 0752 8303/8000 000212 vulnerabilities
- Pfc200 G2 750 821X Xxx Xxx12 vulnerabilities
- Tp600 0762 420X/8000 000X12 vulnerabilities
- Tp600 0762 430X/8000 000X12 vulnerabilities
- Tp600 0762 520X/8000 000X12 vulnerabilities
- Tp600 0762 530X/8000 000X12 vulnerabilities
- Tp600 0762 620X/8000 000X12 vulnerabilities
- Tp600 0762 630X/8000 000X12 vulnerabilities
- WAGO Pfc20012 vulnerabilities
- 752 8303\/8000 00210 vulnerabilities
- Pfc 1009 vulnerabilities
- Pfc 2009 vulnerabilities
- Touch Panel 600 Advanced9 vulnerabilities
- Touch Panel 600 Marine9 vulnerabilities
- Touch Panel 600 Standard9 vulnerabilities
- 750 8202\/000 0128 vulnerabilities
- 750 8202\/000 0228 vulnerabilities
- Cc100 0751/9X018 vulnerabilities
CVE-2018-16210wago750-352_firmware+13
EPSS score0.95%
WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field.CVE-2018-25090wagocontroller bacnet ms/tp+3EPSS score0.40%
An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required. This leads to a limited impact of confidentiality and integrity but no impact of availability.CVE-2018-25108wago750-8100 controller pfc100+3EPSS score0.50%
An unauthenticated remote attacker can cause a DoS in the controller due to uncontrolled resource consumption.CVE-2018-5459wagopfc200_firmwareEPSS score2.68%
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.CVE-2018-12980wago762-3000_firmware+3EPSS score29.80%
An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. The vulnerability allows an authenticated user to upload arbitrary files to the file system with the permissions of the web server.CVE-2018-12981wago762-3000_firmware+3EPSS score5.17%
An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. The vulnerability can be exploited by authenticated and unauthenticated users by sending special crafted requests to the web server allowing injecting code within the WBM. The code will be rendered and/or executed in the browser of the user's browser.CVE-2018-12979wago762-3000_firmware+3EPSS score7.78%
An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. Weak permissions allow an authenticated user to overwrite critical files by abusing the unrestricted file upload in the WBM.CVE-2018-8836wago750-829_firmware+8EPSS score3.71%
Wago 750 Series PLCs with firmware version 10 and prior include a remote attack may take advantage of an improper implementation of the 3 way handshake during a TCP connection affecting the communications with commission and service tools. Specially crafted packets may also be sent to Port 2455/TCP/IP, used in Codesys management software, which may result in a denial-of-service condition of communications with commissioning and service tools.CVE-2021-21001wago750-8202_firmware+28EPSS score1.13%
On WAGO PFC200 devices in different firmware versions with special crafted packets an authorised attacker with network access to the device can access the file system with higher privileges.CVE-2021-21000wago750-8202_firmware+28EPSS score1.04%
On WAGO PFC200 devices in different firmware versions with special crafted packets an attacker with network access to the device could cause a denial of service for the login service of the runtime.CVE-2021-20995wago0852-0303_firmware+4EPSS score0.54%
In multiple managed switches by WAGO in different versions the webserver cookies of the web based UI contain user credentials.CVE-2021-20996wago0852-0303_firmware+4EPSS score0.75%
In multiple managed switches by WAGO in different versions special crafted requests can lead to cookies being transferred to third parties.CVE-2021-20993wago0852-0303_firmware+4EPSS score0.79%
In multiple managed switches by WAGO in different versions the activated directory listing provides an attacker with the index of the resources located inside the directory.CVE-2021-20998wago0852-0303_firmware+4EPSS score1.11%
In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users.CVE-2021-20997wago0852-0303_firmware+4EPSS score1.02%
In multiple managed switches by WAGO in different versions it is possible to read out the password hashes of all Web-based Management users.CVE-2021-20994wago0852-0303_firmware+4EPSS score0.63%
In multiple managed switches by WAGO in different versions an attacker may trick a legitimate user to click a link to inject possible malicious code into the Web-Based Management.CVE-2021-30190codesysv2_web_server+27EPSS score1.39%
CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.CVE-2021-30188codesysv2_runtime_system_sp+27EPSS score1.27%
CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.CVE-2021-30193codesysv2_web_server+27EPSS score1.12%
CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write.CVE-2021-30195codesysplcwinnt+28EPSS score7.55%
CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.