CVE-2014-9188: schneider_electric proclima Command Injection
CVSS: 10.0v2.0HighModified
Published 27-12-2014Last modified 24-07-2025
Vulnerability summary
CVE-2014-9188 is a high (CVSS 10.0) Command Injection vulnerability in schneider_electric proclima. EPSS estimates a 6.29% chance of exploitation in the next 30 days, higher than 93.5% of scored vulnerabilities.
CVSS score
10.0/10
010
High · v2.0 (CVE.org)EPSS score
6.29%
0%100%
Low · 0.00 pp in 30 daysKEVNot listedIn no KEV catalog
RansomwareNone recordedNo known use recorded
Public exploits0No public exploits recorded
Timeline
- 27-12-2014PublishedVulnerability first disclosed.
- 24-07-2025Last modifiedVulnerability information updated.
Description
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
CVSS metrics
2 scores · 2 sources · 1 versionHigh 10.0Preferred score · CVE.org (CNA)
AV:N/AC:L/Au:N/C:C/I:C/A:CSources2 sources · 9.0–10.0
- NVDNIST9.0HighAV:N/AC:L/Au:N/C:C/I:P/A:PDiffers
EPSS trend
Probability
6.29%
Chance of exploitation in the next 30 days
Percentile
94%
Versus all other CVEs
30-day change
0.00 pp
From 6.29% on 19-09-2026
19-09-202619-10-2026
EPSS score6.29%
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
- CWE-119Improper Restriction of Operations within the Bounds of a Memory BufferThe product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.
Affected systems
Schneider_electric1 product
- proclima≤ 6.0.1
1 vendor · 1 product
References
3 links- download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01X Refsource CONFIRMPatchVendor Advisory
- ics-cert.us-cert.gov/advisories/ICSA-14-350-01X Refsource MISCX TransferredPatchThird Party AdvisoryUS Government Resource