6.5

CVE-2017-9657: philips intellivue_mx40_firmware Improper Cleanup on Thrown Exception

CVSS: 6.5v3.0MediumModified
Published 30-04-2018Last modified 16-09-2024

Vulnerability summary

CVE-2017-9657 is a medium (CVSS 6.5) Improper Cleanup on Thrown Exception vulnerability in philips intellivue_mx40_firmware. EPSS estimates a 0.77% chance of exploitation in the next 30 days, higher than 55% of scored vulnerabilities.

Overall risk
26/100
0100
Medium · default modelHow is this calculated?
CVSS score
6.5/10
010
Medium · v3.0 (NVD)
EPSS score
0.77%
0%100%
Low · +0.12 pp in 30 days
KEVNot listedIn no KEV catalog
RansomwareNone recordedNo known use recorded
Public exploits0No public exploits recorded

Timeline

  1. 30-04-2018
    PublishedVulnerability first disclosed.
  2. 16-09-2024
    Last modifiedVulnerability information updated.

Description

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

CVSS metrics

2 scores · 1 source · 2 versions

EPSS trend

Probability

0.77%

Chance of exploitation in the next 30 days

Percentile

55%

Versus all other CVEs

30-day change

+0.12 pp

From 0.65% on 21-09-2026

21-09-202621-10-2026
EPSS score
0.77%

Known exploited

Compare KEV catalogs

Not in any of the 3 tracked catalogs.

Public exploits

0 found

No public exploits indexed.

Weaknesses

CWE · root cause

Affected systems

Philips2 products

1 vendor · 2 products

References

3 links