CVE-2018-4833: siemens rfid_181-eip_firmware Heap-based Buffer Overflow
Vulnerability summary
CVE-2018-4833 is a high (CVSS 8.8) Heap-based Buffer Overflow vulnerability in siemens rfid_181-eip_firmware. EPSS estimates a 0.95% chance of exploitation in the next 30 days, higher than 60.6% of scored vulnerabilities.
Timeline
- 14-06-2018PublishedVulnerability first disclosed.
- 05-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
CVSS metrics
2 scores · 1 source · 2 versionsEPSS trend
Probability
0.95%
Chance of exploitation in the next 30 days
Percentile
61%
Versus all other CVEs
30-day change
0.00 pp
From 0.95% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-122Heap-based Buffer OverflowA heap overflow condition is a buffer overflow, where the buffer that can be overwritten is allocated in the heap portion of memory, generally meaning that the buffer was allocated using a routine such as malloc().
- CWE-20Improper Input ValidationThe product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.
Affected systems
Siemens15 products
- rfid_181-eip_firmwarena
- rfid 181eipAll versions (No fix recorded)
- ruggedcom_wimax_firmware4.4 | 4.5
- ruggedcom winV4.4, V4.5, V5.0, and V5.1
- scalance x-200 switch family (incl. siplus net variants)All versions < V5.2.3
1 vendor · 15 products