CVE-2018-4858: siemens ag iec 61850 system configurator, digsi 5 (affected as iec 61850 system configurator is incorporated), digsi 4, sicam pas/pqs, sicam pq analyzer, sicam scc Improper Access Control
Vulnerability summary
CVE-2018-4858 is a high (CVSS 9.3) Improper Access Control vulnerability in siemens ag iec 61850 system configurator, digsi 5 (affected as iec 61850 system configurator is incorporated), digsi 4, sicam pas/pqs, sicam pq analyzer, sicam scc. EPSS estimates a 1.81% chance of exploitation in the next 30 days, higher than 78.2% of scored vulnerabilities.
Timeline
- 09-07-2018PublishedVulnerability first disclosed.
- 16-09-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
CVSS metrics
2 scores · 1 source · 2 versionsEPSS trend
Probability
1.81%
Chance of exploitation in the next 30 days
Percentile
78%
Versus all other CVEs
30-day change
-0.01 pp
From 1.82% on 19-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root causeAffected systems
Siemens6 products
- digsi_4na
- digsi_5_firmware< 7.80
- ec_61850_system_configurator_firmware< 5.80
- sicam_pas\/pqs< 8.11
- sicam_pq_analyzer_firmware< 3.11
Siemens ag1 product
- iec 61850 system configurator, digsi 5 (affected as iec 61850 system configurator is incorporated), digsi 4, sicam pas/pqs, sicam pq analyzer, sicam sccIEC 61850 system configurator : All versions < V5.80 | DIGSI 5 (affected as IEC 61850 system configurator is incorporated) : All versions < V7.80 | DIGSI 4 : All versions < V4.93 | SICAM PAS/PQS : All versions < V8.11 | SICAM PQ Analyzer : All versions < V3.11 | SICAM SCC : All versions < V9.02 HF3
2 vendors · 7 products