CVE-2018-8856: philips e-alert_firmware Use of Hard-coded Credentials
CVSS: 9.8v3.0CriticalModified
Published 26-09-2018Last modified 17-09-2024
Vulnerability summary
CVE-2018-8856 is a critical (CVSS 9.8) Use of Hard-coded Credentials vulnerability in philips e-alert_firmware. EPSS estimates a 1.38% chance of exploitation in the next 30 days, higher than 71.7% of scored vulnerabilities.
CVSS score
9.8/10
010
Critical · v3.0 (NVD)EPSS score
1.38%
0%100%
Low · 0.00 pp in 30 daysKEVNot listedIn no KEV catalog
RansomwareNone recordedNo known use recorded
Public exploits0No public exploits recorded
Timeline
- 26-09-2018PublishedVulnerability first disclosed.
- 17-09-2024Last modifiedVulnerability information updated.
Description
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
CVSS metrics
2 scores · 1 source · 2 versionsCritical 9.8Preferred score · NVD (NIST)
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HSourcesSingle source
Medium 5.0Preferred score · NVD (NIST)
AV:N/AC:L/Au:N/C:P/I:N/A:NSourcesSingle source
EPSS trend
Probability
1.38%
Chance of exploitation in the next 30 days
Percentile
72%
Versus all other CVEs
30-day change
0.00 pp
From 1.38% on 20-09-2026
20-09-202620-10-2026
EPSS score1.38%
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root causeAffected systems
Philips2 products
- e-alert_firmware≤ r2.1
- e-alert unit (non-medical device)R2.1 and prior
1 vendor · 2 products
References
3 links- www.usa.philips.com/healthcare/about/customer-support/product-securityX Refsource CONFIRMVendor Advisory
- ics-cert.us-cert.gov/advisories/ICSA-18-242-01X Refsource MISCMitigationThird Party AdvisoryUS Government Resource