CVE-2019-13924: siemens scalance_s602_firmware Protection Mechanism Failure
Vulnerability summary
CVE-2019-13924 is a medium (CVSS 5.4) Protection Mechanism Failure vulnerability in siemens scalance_s602_firmware. EPSS estimates a 0.83% chance of exploitation in the next 30 days, higher than 56.6% of scored vulnerabilities.
Timeline
- 11-02-2020PublishedVulnerability first disclosed.
- 05-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
CVSS metrics
2 scores · 1 source · 2 versionsEPSS trend
Probability
0.83%
Chance of exploitation in the next 30 days
Percentile
57%
Versus all other CVEs
30-day change
0.00 pp
From 0.83% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-693Protection Mechanism FailureThe product does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.
- CWE-1021Improper Restriction of Rendered UI Layers or FramesThe web application does not restrict or incorrectly restricts frame objects or UI layers that belong to another application or domain.
Affected systems
Siemens15 products
- scalance_s602_firmwareAll versions < V4.1
- scalance_s612_firmwareAll versions < V4.1
- scalance_s623_firmwareAll versions < V4.1
- scalance_s627-2m_firmwareAll versions < V4.1
- scalance x-200 switch family (incl. siplus net variants)All versions < 5.2.4
1 vendor · 15 products
References
2 links- cert-portal.siemens.com/productcert/pdf/ssa-951513.pdfVendor Advisory