CVE-2019-13945: siemens ag simatic s7-1200 cpu family < v4.x (incl. siplus variants) Exposed Dangerous Method or Function
Vulnerability summary
CVE-2019-13945 is a medium (CVSS 6.8) Exposed Dangerous Method or Function vulnerability in siemens ag simatic s7-1200 cpu family < v4.x (incl. siplus variants). EPSS estimates a 0.53% chance of exploitation in the next 30 days, higher than 43.5% of scored vulnerabilities.
Timeline
- 12-12-2019PublishedVulnerability first disclosed.
- 05-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
CVSS metrics
2 scores · 1 source · 2 versionsEPSS trend
Probability
0.53%
Chance of exploitation in the next 30 days
Percentile
44%
Versus all other CVEs
30-day change
0.00 pp
From 0.53% on 19-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root causeAffected systems
Siemens ag18 products
- simatic s7-1200 cpu family < v4.x (incl. siplus variants)All versions (No fix recorded)
- simatic s7-1200 cpu family (incl. siplus variants)All versions (No fix recorded)
- simatic s7-1200 cpu family v4.x (incl. siplus variants)All versions with Function State (FS) < 11
- simatic s7-200 smart cpu cr20s (6es7 288-1cr20-0aa1)All versions <= V2.3.0 and Function State (FS) <= 3
- simatic s7-200 smart cpu cr30s (6es7 288-1cr30-0aa1)All versions <= V2.3.0 and Function State (FS) <= 3
Siemens14 products
- simatic_s7-200_smart_cpu_cr20s_firmware≤ 2.3.0
- simatic_s7-200_smart_cpu_cr30s_firmware≤ 2.3.0
- simatic_s7-200_smart_cpu_cr40_firmware≤ 2.2.2
- simatic_s7-200_smart_cpu_cr40s_firmware≤ 2.3.0
- simatic_s7-200_smart_cpu_cr60_firmware≤ 2.2.2
2 vendors · 32 products