Vulnerability summary
CVE-2019-1614 is a high (CVSS 9.0) Command Injection vulnerability in cisco mds 9000 series multilayer switches. EPSS estimates a 4.07% chance of exploitation in the next 30 days, higher than 90.5% of scored vulnerabilities.
Timeline
- 11-03-2019PublishedVulnerability first disclosed.
- 20-11-2024Last modifiedVulnerability information updated.
Description
A vulnerability in the NX-API feature of Cisco NX-OS Software could allow an authenticated, remote attacker to execute arbitrary commands with root privileges. The vulnerability is due to incorrect input validation of user-supplied data by the NX-API subsystem. An attacker could exploit this vulnerability by sending malicious HTTP or HTTPS packets to the management interface of an affected system that has the NX-API feature enabled. A successful exploit could allow the attacker to perform a command-injection attack and execute arbitrary commands with root privileges. Note: NX-API is disabled by default. MDS 9000 Series Multilayer Switches are affected running software versions prior to 8.1(1b) and 8.2(3). Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected running software versions prior to 7.3(4)N1(1). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 7000 and 7700 Series Switches are affected running software versions prior to 7.3(3)D1(1) and 8.2(3).
CVSS metrics
4 scores · 2 sources · 3 versions- NVDNIST8.8HighCVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS trend
Probability
4.07%
Chance of exploitation in the next 30 days
Percentile
91%
Versus all other CVEs
30-day change
0.00 pp
From 4.07% on 19-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
- CWE-78Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
Affected systems
Cisco7 products
- mds 9000 series multilayer switches≥ unspecified, < 8.1(1b) | ≥ unspecified, < 8.2(3)
- nexus 2000, 5500, 5600, and 6000 series switches≥ unspecified, < 7.3(4)N1(1)
- nexus 3000 series switches≥ unspecified, < 7.0(3)I4(9) | ≥ unspecified, < 7.0(3)I7(4)
- nexus 3500 platform switches≥ unspecified, < 7.0(3)I7(4)
- nexus 7000 and 7700 series switches≥ unspecified, < 7.3(3)D1(1) | ≥ unspecified, < 8.2(3)
1 vendor · 7 products
References