CVE-2022-46353: siemens 6gk5204-0ba00-2kb2_firmware Use of Insufficiently Random Values
Vulnerability summary
CVE-2022-46353 is a critical (CVSS 9.8) Use of Insufficiently Random Values vulnerability in siemens 6gk5204-0ba00-2kb2_firmware. EPSS estimates a 1.07% chance of exploitation in the next 30 days, higher than 64.2% of scored vulnerabilities.
Timeline
- 13-12-2022PublishedVulnerability first disclosed.
- 22-04-2025Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
CVSS metrics
2 scores · 2 sources · 1 version- NVDNIST9.8CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS trend
Probability
1.07%
Chance of exploitation in the next 30 days
Percentile
64%
Versus all other CVEs
30-day change
+0.07 pp
From 1.00% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root causeAffected systems
Siemens10 products
- 6gk5204-0ba00-2kb2_firmware< 3.2.7
- 6gk5204-0ba00-2mb2_firmware< 3.2.7
- 6gk5204-0bs00-2na3_firmware< 3.2.7
- 6gk5204-0bs00-3la3_firmware< 3.2.7
- 6gk5204-0bs00-3pa3_firmware< 3.2.7
1 vendor · 10 products