CVE-2023-26293: siemens tia_portal Improper Input Validation
Vulnerability summary
CVE-2023-26293 is a high (CVSS 7.3) Improper Input Validation vulnerability in siemens tia_portal. EPSS estimates a 0.25% chance of exploitation in the next 30 days, higher than 15.1% of scored vulnerabilities.
Timeline
- 11-04-2023PublishedVulnerability first disclosed.
- 25-11-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
CVSS metrics
2 scores · 2 sources · 1 version- NVDNIST7.3HighCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L
EPSS trend
Probability
0.25%
Chance of exploitation in the next 30 days
Percentile
15%
Versus all other CVEs
30-day change
0.00 pp
From 0.25% on 19-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-20Improper Input ValidationThe product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.
- CWE-22Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.
Affected systems
Siemens5 products
- tia_portal15 | 16 | 17 | 17:update1 | 17:update2 | 17:update3 | 17:update4 | 17:update5 | 18
- totally integrated automation portal (tia portal) v15All versions (No fix recorded)
- totally integrated automation portal (tia portal) v16< V16 Update 7
- totally integrated automation portal (tia portal) v17< V17 Update 6
- totally integrated automation portal (tia portal) v18< V18 Update 1
1 vendor · 5 products