CVE-2023-32735: siemens simatic step 7 safety v16 Deserialization of Untrusted Data
Vulnerability summary
CVE-2023-32735 is a high (CVSS 7.0) Deserialization of Untrusted Data vulnerability in siemens simatic step 7 safety v16. EPSS estimates a 0.21% chance of exploitation in the next 30 days, higher than 10.8% of scored vulnerabilities.
Timeline
- 09-07-2024PublishedVulnerability first disclosed.
- 27-08-2025Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
CVSS metrics
4 scores · 2 sources · 2 versions- NVDNIST7.0HighCVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- NVDNIST6.5MediumCVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H
EPSS trend
Probability
0.21%
Chance of exploitation in the next 30 days
Percentile
11%
Versus all other CVEs
30-day change
0.00 pp
From 0.21% on 18-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root causeAffected systems
Siemens27 products
- simatic step 7 safety v16< V16 Update 7
- simatic step 7 safety v17< V17 Update 7
- simatic step 7 safety v18< V18 Update 2
- simatic step 7 v16< V16 Update 7
- simatic step 7 v17< V17 Update 7
1 vendor · 27 products