CVE-2024-25955: dell powermax_eem OS Command Injection
CVSS: 8.8v3.1HighAnalyzed
Published 28-03-2024Last modified 01-08-2024
Vulnerability summary
CVE-2024-25955 is a high (CVSS 8.8) OS Command Injection vulnerability in dell powermax_eem. EPSS estimates a 1.44% chance of exploitation in the next 30 days, higher than 72.7% of scored vulnerabilities.
CVSS score
8.8/10
010
High · v3.1 (NVD)EPSS score
1.44%
0%100%
Low · 0.00 pp in 30 daysKEVNot listedIn no KEV catalog
RansomwareNone recordedNo known use recorded
Public exploits0No public exploits recorded
Timeline
- 28-03-2024PublishedVulnerability first disclosed.
- 01-08-2024Last modifiedVulnerability information updated.
Description
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
CVSS metrics
2 scores · 2 sources · 1 versionHigh 8.8Preferred score · NVD (NIST)
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HSources2 sources · 7.2–8.8
- CVE.orgCNA7.2HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HDiffers
EPSS trend
Probability
1.44%
Chance of exploitation in the next 30 days
Percentile
73%
Versus all other CVEs
30-day change
0.00 pp
From 1.44% on 20-09-2026
20-09-202620-10-2026
EPSS score1.44%
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-78Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
Affected systems
Dell4 products
- powermax_eem5978
- solutions_enabler_virtual_appliance< 9.2.4.6
- unisphere_for_powermax_virtual_appliance< 9.2.4.9
- virtual appliance (vapp) manager≥ N/A, < 9.2.4.9 | ≥ N/A, < 9.2.4.6 | ≥ N/A, < 5978
1 vendor · 4 products
References
1 links- www.dell.com/support/…Vendor Advisory