Description
A10 Thunder ADC CsrRequestView Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of A10 Thunder ADC. Authentication is required to exploit this vulnerability. The specific flaw exists within the CsrRequestView class. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of a10user. Was ZDI-CAN-22517.
CVSS metrics
3 scores · 2 sources · 2 versions- NVDNIST7.2HighCVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
EPSS trend
Probability
3.02%
Chance of exploitation in the next 30 days
Percentile
87%
Versus all other CVEs
30-day change
No change 0.00 pp
From 3.02% on 04-10-2026
Known exploited
Compare KEV catalogsNot in the CISA KEV catalog.
Not in the ENISA CNW catalog.
Not in the CIRCL catalog.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-78Improper Neutralization of Special Elements used in an OS CommandThe product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.
- CWE-77Improper Neutralization of Special Elements used in a CommandThe product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
Affected systems
Known conditions: network-reachable, administrative account, no user interaction (CVSS vector). Other conditions: not stated in public data.
A101 product
- thunder adc6.0.2, build 68
A10networks1 product
- advanced_core_operating_system4.1.4 | 4.1.4:gr1 | 4.1.4:gr1-p1 | 4.1.4:gr1-p10 | 4.1.4:gr1-p11 | 4.1.4:gr1-p12 | 4.1.4:gr1-p13 | 4.1.4:gr1-p2 | 4.1.4:gr1-p3 | 4.1.4:gr1-p4 | 4.1.4:gr1-p5 | 4.1.4:gr1-p6 | 4.1.4:gr1-p7 | 4.1.4:gr1-p8 | 4.1.4:gr1-p9 | 4.1.4:p1 | 4.1.4:p2 | 4.1.4:p3 | 5.1.0 | 5.1.0:p3 | 5.1.0:p4 | 5.1.0:p5 | 5.1.0:p6 | 5.2.0 | 5.2.0:p1 | 5.2.1 | 5.2.1:p1 | 5.2.1:p2 | 5.2.1:p3 | 5.2.1:p4 | 5.2.1:p5 | 5.2.1:p6 | 5.2.1:p7 | 5.2.1:p8 | 5.2.1:p9 | 6.0.0 | 6.0.0:p1 | 6.0.0:p2 | 6.0.0:p2-sp1 | 6.0.1 | 6.0.2 | 6.0.2:p1 | 6.0.3