CVE-2024-40415: tenda ax1806_firmware Out-of-bounds Write
Modified
Published 15-07-2024Last modified 02-08-2024
Vulnerability summary
CVE-2024-40415 is a critical (CVSS 9.8) Out-of-bounds Write vulnerability in tenda ax1806_firmware. EPSS estimates a 0.46% chance of exploitation in the next 30 days, higher than 39.1% of scored vulnerabilities.
CVSS score
9.8/10
010
Critical · v3.1 (CVE.org)EPSS score
0.46%
0%100%
Low · 0.00 pp in 30 daysKEVNot listedNot listed by any tracked catalog.
RansomwareNot flaggedNo ransomware use recorded.
Public exploits0No public exploits recorded
Timeline
- 15-07-2024PublishedVulnerability first disclosed.
- 02-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability in /goform/SetStaticRouteCfg in the sub_519F4 function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
CVSS metrics
2 scores · 2 sources · 1 versionCritical 9.8Preferred score · CVE.org (CNA)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HSourcesAll 2 agree
- NVDNIST9.8CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS trend
Probability
0.46%
Chance of exploitation in the next 30 days
Percentile
39%
Versus all other CVEs
30-day change
No change 0.00 pp
From 0.46% on 22-09-2026
22-09-202622-10-2026
Known exploited
Compare KEV catalogsNot in the CISA KEV catalog.
Not in the ENISA CNW catalog.
Not in the CIRCL catalog.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-787Out-of-bounds WriteThe product writes data past the end, or before the beginning, of the intended buffer.
- CWE-120Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer.
Affected systems
Tenda1 product
- ax1806_firmware1.0.0.1
1 vendor · 1 product