CVE-2025-27212: ubiquiti inc unifi access g2 reader pro Improper Input Validation
Vulnerability summary
CVE-2025-27212 is a critical (CVSS 9.8) Improper Input Validation vulnerability in ubiquiti inc unifi access g2 reader pro. EPSS estimates a 1.21% chance of exploitation in the next 30 days, higher than 67.8% of scored vulnerabilities.
Timeline
- 04-08-2025PublishedVulnerability first disclosed.
- 05-08-2025Last modifiedVulnerability information updated.
Description
An Improper Input Validation in certain UniFi Access devices could allow a Command Injection by a malicious actor with access to UniFi Access management network. Affected Products: UniFi Access Reader Pro (Version 2.14.21 and earlier) UniFi Access G2 Reader Pro (Version 1.10.32 and earlier) UniFi Access G3 Reader Pro (Version 1.10.30 and earlier) UniFi Access Intercom (Version 1.7.28 and earlier) UniFi Access G3 Intercom (Version 1.7.29 and earlier) UniFi Access Intercom Viewer (Version 1.3.20 and earlier) Mitigation: Update UniFi Access Reader Pro Version 2.15.9 or later Update UniFi Access G2 Reader Pro Version 1.11.23 or later Update UniFi Access G3 Reader Pro Version 1.11.22 or later Update UniFi Access Intercom Version 1.8.22 or later Update UniFi Access G3 Intercom Version 1.8.22 or later Update UniFi Access Intercom Viewer Version 1.4.39 or later
CVSS metrics
2 scores · 2 sources · 1 version- NVDNIST9.8CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS trend
Probability
1.21%
Chance of exploitation in the next 30 days
Percentile
68%
Versus all other CVEs
30-day change
0.00 pp
From 1.21% on 20-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-20Improper Input ValidationThe product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.
- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
Affected systems
Ubiquiti inc6 products
- unifi access g2 reader pro≥ 1.11.23, < 1.11.23
- unifi access g3 intercom≥ 1.8.22, < 1.8.22
- unifi access g3 reader pro≥ 1.11.22, < 1.11.22
- unifi access intercom≥ 1.8.22, < 1.8.22
- unifi access intercom viewer≥ 1.4.39, < 1.4.39
1 vendor · 6 products