CVE-2025-7952: totolink t6_firmware Injection
Vulnerability summary
CVE-2025-7952 is a high (CVSS 8.8) Injection vulnerability in totolink t6_firmware. EPSS estimates a 21.29% chance of exploitation in the next 30 days, higher than 97.5% of scored vulnerabilities. 1 public exploit is recorded.
Timeline
- 22-07-2025PublishedVulnerability first disclosed.
- 22-07-2025Last modifiedVulnerability information updated.
Description
A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. This vulnerability affects the function ckeckKeepAlive of the file wireless.so of the component MQTT Packet Handler. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVSS metrics
7 scores · 2 sources · 4 versions- NVDNIST2.1LowCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XDiffers
- CVE.orgCNA6.3MediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:RDiffers
- NVDNIST6.5MediumAV:N/AC:L/Au:S/C:P/I:P/A:P
EPSS trend
Probability
21.29%
Chance of exploitation in the next 30 days
Percentile
98%
Versus all other CVEs
30-day change
+0.34 pp
From 20.95% on 21-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
1 foundPublic
Maturity: poc
Weaknesses
CWE · root cause- CWE-74Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.
- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
Affected systems
Totolink1 product
- t6_firmware4.1.5cu.748 | v4.1.5cu.748_b20211015
1 vendor · 1 product
References
6 links- www.totolink.netProduct