CVE-2026-113389: draytek vigor2960 Injection
Vulnerability summary
CVE-2026-113389 is a critical (CVSS 9.9) Injection vulnerability in draytek vigor2960. 1 public exploit is recorded.
Timeline
- 20-10-2026PublishedVulnerability first disclosed.
- 20-10-2026Last modifiedVulnerability information updated.
Description
A vulnerability was detected in DrayTek Vigor2960 1.5.1.6 Revision 8218. Affected by this vulnerability is the function set_table of the file /cgi-bin/mainfunction.cgi of the component CGI Process. The manipulation of the argument sectiontype results in command injection. The attack may be launched remotely. The exploit is now public and may be used. The vendor explains: "2960 1.5.1.7 has corrected many security issues. And 2960 is EoS with limited support, only major issues would be reviewed(e.g. unauthenticated vuln.)". This vulnerability only affects products that are no longer supported by the maintainer.
CVSS metrics
7 scores · 2 sources · 4 versions- NVDNIST8.6HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XDiffers
- NVDNIST9.9CriticalCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
- NVDNIST9.0HighAV:N/AC:L/Au:S/C:C/I:C/A:C
EPSS trend
No EPSS score has been published for this record yet.
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
1 foundDraytek Vigor2960 Security Analysis
Maturity: poc
Weaknesses
CWE · root cause- CWE-74Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.
- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
Affected systems
Draytek1 product
- vigor29601.5.1.6 Revision 8218
1 vendor · 1 product
References
5 links- vuldb.com/cve/CVE-2026-113389Third Party Advisory
- vuldb.com/submit/992223Third Party Advisory
- github.com/yikesoftware/…Exploit