CVE-2026-116506: TOTOLINK A950RG firewall.so apmib_set command injection
Received
Published 26-10-2026Last modified 26-10-2026
Vulnerability summary
CVE-2026-116506 is a critical (CVSS 9.9) Injection vulnerability in totolink a950rg. 1 public exploit is recorded.
CVSS score
9.9/10
010
Critical · v3.1 (CVE.org)EPSS scoreNot scoredRisk metrics not yet published.
KEVNot listedNot listed by any tracked catalog.
RansomwareNot flaggedNo ransomware use recorded.
Public exploits1github
Timeline
- 26-10-2026PublishedVulnerability first disclosed.
Description
A vulnerability was determined in TOTOLINK A950RG 4.1.2cu.5268_B20221104. Affected is the function apmib_set of the file firewall.so. This manipulation causes command injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
CVSS metrics
7 scores · 2 sources · 4 versionsCritical 9.4Preferred score · CVE.org (CNA)
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:PSources2 sources · 8.6–9.4
- NVDNIST8.6HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XDiffers
Critical 9.9Preferred score · CVE.org (CNA)
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:RSourcesAll 2 agree
- NVDNIST9.9CriticalCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Critical 9.9Preferred score · CVE.org (CNA)
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:RSourcesSingle source
High 9.0Preferred score · CVE.org (CNA)
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:URSourcesAll 2 agree
- NVDNIST9.0HighAV:N/AC:L/Au:S/C:C/I:C/A:C
EPSS trend
No EPSS score has been published for this record yet.
Known exploited
Compare KEV catalogsNot in the CISA KEV catalog.
Not in the ENISA CNW catalog.
Not in the CIRCL catalog.
Public exploits
1 found1046036A8601E93F375754E11307Bfc8
Maturity: poc
Weaknesses
CWE · root cause- CWE-74Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.
- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
Affected systems
Totolink1 product
- a950rg4.1.2cu.5268_B20221104
1 vendor · 1 product
References
6 links- vuldb.com/cve/CVE-2026-116506Third Party Advisory
- vuldb.com/submit/1022555Third Party Advisory
- www.totolink.netProduct