CVE-2026-2063: d-link dir-823x Command Injection
Vulnerability summary
CVE-2026-2063 is a high (CVSS 7.2) Command Injection vulnerability in d-link dir-823x. EPSS estimates a 5.29% chance of exploitation in the next 30 days, higher than 92.5% of scored vulnerabilities. 1 public exploit is recorded.
Timeline
- 06-02-2026PublishedVulnerability first disclosed.
- 23-02-2026Last modifiedVulnerability information updated.
Description
A security flaw has been discovered in D-Link DIR-823X 250416. This vulnerability affects unknown code of the file /goform/set_ac_server of the component Web Management Interface. The manipulation of the argument ac_server results in os command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.
CVSS metrics
7 scores · 2 sources · 4 versions- NVDNIST2.0LowCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XDiffers
- CVE.orgCNA4.7MediumCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:RDiffers
- NVDNIST5.8MediumAV:N/AC:L/Au:M/C:P/I:P/A:P
EPSS trend
Probability
5.29%
Chance of exploitation in the next 30 days
Percentile
93%
Versus all other CVEs
30-day change
+0.71 pp
From 4.58% on 21-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
1 foundCve
Maturity: poc
Weaknesses
CWE · root cause- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
- CWE-78Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
Affected systems
D-link1 product
- dir-823x250416
Dlink1 product
- dir-823x_firmware250416
2 vendors · 2 products
References
5 links- www.dlink.comProduct