CVE-2026-86167: Tenda HG10 Boa formgponConf os command injection
Vulnerability summary
CVE-2026-86167 is a critical (CVSS 9.9) Command Injection vulnerability in tenda hg10_firmware. EPSS estimates a 2.73% chance of exploitation in the next 30 days, higher than 85.9% of scored vulnerabilities. 1 public exploit is recorded.
Timeline
- 06-09-2026PublishedVulnerability first disclosed.
- 08-09-2026Last modifiedVulnerability information updated.
Description
A vulnerability was identified in Tenda HG10 300001138. Impacted is the function formgponConf of the file /boaform/admin/formgponConf of the component Boa. The manipulation of the argument fmgpon_loid leads to os command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CVSS metrics
7 scores · 2 sources · 4 versions- NVDNIST8.6HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XDiffers
- NVDNIST9.9CriticalCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
- NVDNIST9.0HighAV:N/AC:L/Au:S/C:C/I:C/A:C
EPSS trend
Probability
2.73%
Chance of exploitation in the next 30 days
Percentile
86%
Versus all other CVEs
30-day change
Increase +1.10 pp
From 1.63% on 22-09-2026
Known exploited
Compare KEV catalogsNot in the CISA KEV catalog.
Not in the ENISA CNW catalog.
Not in the CIRCL catalog.
Public exploits
1 foundCuicuishark Sheep Fishiot
Maturity: poc
Weaknesses
CWE · root cause- CWE-77Improper Neutralization of Special Elements used in a Command ('Command Injection')The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
- CWE-78Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
Affected systems
Tenda1 product
- hg10_firmware300001138
1 vendor · 1 product
References
6 links- vuldb.com/cve/CVE-2026-86167Third Party Advisory
- vuldb.com/submit/895596Third Party Advisory
- github.com/SunnyYANGyaya/…Exploit
- www.tenda.com.cnProduct