Security update for xen xen was updated to fix nine security issues. These security issues were fixed: - CVE-2015-4037: The slirp_smb function in net/slirp.c created temporary files with predictable names, which allowed local users to cause a denial of service (instantiation failure) by creating /tmp/qemu-smb.*-* files before the program (bsc#932267). - CVE-2014-0222: Integer overflow in the qcow_open function allowed remote attackers to cause a denial of service (crash) via a large L2 table in a QCOW version 1 image (bsc#877642). - CVE-2015-7835: Uncontrolled creation of large page mappings by PV guests (bsc#950367). - CVE-2015-7311: libxl in Xen did not properly handle the readonly flag on disks when using the qemu-xen device model, which allowed local guest users to write to a read-only disk image (bsc#947165). - CVE-2015-5239: Integer overflow in vnc_client_read() and protocol_client_msg() (bsc#944463). - CVE-2015-6815: With e1000 NIC emulation support it was possible to enter an infinite loop (bsc#944697). - CVE-2015-7969: Leak of main per-domain vcpu pointer array leading to denial of service (bsc#950703). - CVE-2015-7969: Leak of per-domain profiling- related vcpu pointer array leading to denial of service (bsc#950705). - CVE-2015-7971: Some pmu and profiling hypercalls log without rate limiting (bsc#950706). These non-security issues were fixed: - bsc#907514: Bus fatal error: SLES 12 sudden reboot has been observed - bsc#910258: SLES12 Xen host crashes with FATAL NMI after shutdown of guest with VT-d NIC - bsc#918984: Bus fatal error: SLES11-SP4 sudden reboot has been observed - bsc#923967: Partner-L3: Bus fatal error: SLES11-SP3 sudden reboot has been observed - bsc#941074: Device 51728 could not be connected. Hotplug scripts not working
CVSS metrics
Risk metrics not yet published.
EPSS trend
No EPSS score has been published for this record yet.
Known exploited
Compare KEV catalogsNot in the CISA KEV catalog.
Not in the ENISA CNW catalog.
Not in the CIRCL catalog.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root causeNo weakness data has been published for this record.
Affected systems
Known conditions: not stated in public data.
Suse5 products
- xen&distro=SUSE Linux Enterprise Desktop 11 SP3< 4.2.5_14-18.2
- xen&distro=SUSE Linux Enterprise Server 11 SP3< 4.2.5_14-18.2
- xen&distro=SUSE Linux Enterprise Server 11 SP3-TERADATA< 4.2.5_14-18.2
- xen&distro=SUSE Linux Enterprise Server for SAP Applications 11 SP3< 4.2.5_14-18.2
- xen&distro=SUSE Linux Enterprise Software Development Kit 11 SP3< 4.2.5_14-18.2
1 vendor · 5 products
References
23 links- bugzilla.suse.com/877642REPORT
- bugzilla.suse.com/907514REPORT
- bugzilla.suse.com/910258REPORT
- bugzilla.suse.com/918984REPORT
- bugzilla.suse.com/923967REPORT
- bugzilla.suse.com/932267REPORT
- bugzilla.suse.com/941074REPORT
- bugzilla.suse.com/944463REPORT
- bugzilla.suse.com/944697REPORT
Show all 23 references
- bugzilla.suse.com/947165REPORT
- bugzilla.suse.com/950367REPORT
- bugzilla.suse.com/950703REPORT
- bugzilla.suse.com/950705REPORT
- bugzilla.suse.com/950706REPORT