Deltaww Infrasuite Device Master vulnerabilities
31 vulnerabilities
Known vulnerabilities in Deltaww Infrasuite Device Master, newest first, with CVSS severity, EPSS, KEV listings, ransomware use and the affected versions.
CVE-2022-40202delta electronicsinfrasuite device master+1
EPSS score1.40%
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.CVE-2022-41778delta electronicsinfrasuite device master+1EPSS score1.03%
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.CVE-2022-41629delta electronicsinfrasuite device master+1EPSS score0.67%
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.CVE-2022-41644delta electronicsinfrasuite device master+1EPSS score0.77%
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.CVE-2022-41657delta electronicsinfrasuite device master+1EPSS score20.90%
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.CVE-2022-41776delta electronicsinfrasuite device master+1EPSS score0.58%
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.CVE-2022-41779delta electronicsinfrasuite device master+1EPSS score1.19%
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.CVE-2022-41688delta electronicsinfrasuite device master+1EPSS score0.71%
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.CVE-2022-41772delta electronicsinfrasuite device master+1EPSS score24.95%
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.CVE-2022-38142delta electronicsinfrasuite device master+1EPSS score18.21%
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.CVE-2023-1140delta electronicsinfrasuite device master+1EPSS score1.08%
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.CVE-2023-1144delta electronicsinfrasuite device master+1EPSS score0.65%
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.CVE-2023-1141delta electronicsinfrasuite device master+1EPSS score1.58%
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution.CVE-2023-1137delta electronicsinfrasuite device master+1EPSS score0.55%
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation.CVE-2023-1138delta electronicsinfrasuite device master+1EPSS score0.57%
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials.CVE-2023-1135delta electronicsinfrasuite device master+1EPSS score0.16%
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation.CVE-2023-1145delta electronicsinfrasuite device master+1EPSS score0.31%
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.CVE-2023-1134delta electronicsinfrasuite device master+1EPSS score0.66%
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.CVE-2023-1136delta electronicsinfrasuite device master+1EPSS score0.74%
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass.CVE-2023-1142delta electronicsinfrasuite device master+1EPSS score1.09%
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.