Hitachi Energy vulnerabilities, page 3
115 vulnerabilities
Known vulnerabilities in Hitachi Energy products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 60 products.
CVE-2022-29490hitachi energymicroscada x sys600+1
EPSS score0.64%
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*CVE-2022-29492hitachi energymicroscada pro sys600+2EPSS score0.75%
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*CVE-2022-29922hitachi energymicroscada pro sys600+2EPSS score0.79%
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*CVE-2022-28613abbrtu500_firmware+2EPSS score0.99%
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.CVE-2022-3353hitachi energyfox61x tego1+25EPSS score1.10%
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.
An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.
Already existing/established client-server connections are not affected.
List of affected CPEs:
* cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*CVE-2022-3928hitachi energyfoxman-un+3EPSS score0.22%
Hardcoded credential is found in affected products' message queue. An attacker that manages to exploit this vulnerability will be able to access data to the internal message queue.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*CVE-2022-3683hitachi energysdm600+1EPSS score0.48%
A vulnerability exists in the SDM600 API web services authorization validation implementation.
An attacker who successfully exploits the vulnerability could read data directly from a data store that is not restricted, or insufficiently protected, having access to sensitive data.
This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291)
List of CPEs:
* cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*CVE-2022-3388hitachi energymicroscada pro sys600+3EPSS score0.29%
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA
Pro and MicroSCADA X SYS600. An authenticated user can launch an administrator level remote code execution irrespective of the authenticated user's role.CVE-2022-3684hitachi energysdm600+1EPSS score0.62%
A vulnerability exists in a SDM600 endpoint.
An attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive.
This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291)
List of CPEs:
* cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*CVE-2022-3927hitachi energyfoxman-un+3EPSS score0.58%
The affected products store both public and private key that are used to sign and
protect Custom Parameter Set (CPS) file from modification. An attacker that manages to exploit this vulnerability will be able to change
the CPS file, sign it so that it is trusted as the legitimate CPS file.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*CVE-2022-3686hitachi energysdm600+1EPSS score1.44%
A vulnerability exists in a SDM600 endpoint.
An attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive.
This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291)
List of CPEs:
* cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*CVE-2022-3682hitachi energysdm600+1EPSS score0.78%
A vulnerability exists in the SDM600 file permission validation.
An attacker could exploit the vulnerability by gaining access to the system and uploading a specially crafted message to the system node, which could result in Arbitrary code Executing.
This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291)
List of CPEs:
* cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*CVE-2022-3929hitachi energyfoxman-un+3EPSS score0.40%
Communication between the client and the server application of the affected products is partially done using CORBA (Common Object Request Broker Architecture) over TCP/IP. This protocol is not encrypted and allows tracing of internal messages.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*CVE-2022-3864hitachi energyrelion 670/650/sam600-io series+3EPSS score0.35%
A vulnerability exists in the Relion update package signature validation. A tampered update package could cause the IED to restart. After restart the device is back to normal operation.
An attacker could exploit the vulnerability by first gaining access to
the system with security privileges and attempt to update the IED
with a malicious update package. Successful exploitation of this
vulnerability will cause the IED to restart, causing a temporary Denial of Service.CVE-2022-3685hitachi energysdm600+1EPSS score0.34%
A vulnerability exists in the SDM600 software. The software operates at a privilege level that is higher than the minimum level required. An attacker who successfully exploits this vulnerability can escalate privileges.
This issue affects: All SDM600 versions prior to version 1.3.0.
List of CPEs:
* cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:sdm600:1.3.0.1339:*:*:*:*:*:*:*CVE-2024-2617hitachi energyrtu500 series cmu firmwareEPSS score0.66%
A vulnerability exists in the RTU500 that allows for authenticated and authorized users to bypass secure update,
if secure update feature was not enabled on all
CMUs of a RTU500. If a
malicious actor successfully exploits this vulnerability, they
could use it to update the RTU500 with unsigned firmware.CVE-2024-2244hitachi energyasset suite eamEPSS score0.37%
REST service authentication anomaly with “valid username/no password” credential combination for batch job processing resulting in successful service invocation. The anomaly doesn’t exist with other credential combinations.CVE-2024-2013hitachi energyfoxman-un+3EPSS score0.68%
An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server /
API Gateway component that if exploited allows attackers without
any access to interact with the services and the post-authentication
attack surface.CVE-2024-2378hitachi energysdm600EPSS score0.22%
A vulnerability exists in the web-authentication component of the SDM600. If exploited an attacker could escalate privileges on af-fected installations.CVE-2024-2461hitachi energyfox61x+1EPSS score0.50%
If exploited an attacker could traverse the file system to access
files or directories that would otherwise be inaccessible