Hitachienergy vulnerabilities
103 vulnerabilities
Known vulnerabilities in Hitachienergy products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 46 products.
Products
46- Esoms19 vulnerabilities
- Microscada X Sys60019 vulnerabilities
- Foxman Un13 vulnerabilities
- Unem13 vulnerabilities
- Relion 6708 vulnerabilities
- Relion 6507 vulnerabilities
- Rtu5007 vulnerabilities
- Relion Sam600 Io6 vulnerabilities
- Rtu5206 vulnerabilities
- Rtu5306 vulnerabilities
- Rtu5406 vulnerabilities
- Rtu5606 vulnerabilities
- Sdm6005 vulnerabilities
- Microscada Pro Sys6004 vulnerabilities
- Modular Switchgear Monitoring4 vulnerabilities
- Reb5004 vulnerabilities
- Txpert Hub Coretec 44 vulnerabilities
- Gms6003 vulnerabilities
- Pwc6003 vulnerabilities
- Asset Suite2 vulnerabilities
- Ellipse Enterprise Asset Management2 vulnerabilities
- Fox515T2 vulnerabilities
- Fox6152 vulnerabilities
- Fox615 Tego12 vulnerabilities
- Modular Advanced Control For Hvdc2 vulnerabilities
- Retail Operations2 vulnerabilities
- Sys6002 vulnerabilities
- Tro6102 vulnerabilities
- Tro6202 vulnerabilities
- Tro6702 vulnerabilities
- Xcm202 vulnerabilities
- 650Connectivitypackage1 vulnerabilities
- 670Connectivitypackage1 vulnerabilities
- Counterparty Settlement And Billing1 vulnerabilities
- Counterparty Settlements And Billing1 vulnerabilities
- Ellipse1 vulnerabilities
- Foxman Un1 vulnerabilities
- Gms600Connectivitypackage1 vulnerabilities
- Itt600 Sa Explorer1 vulnerabilities
- Lumada Asset Performance Management1 vulnerabilities
- Pcm6001 vulnerabilities
- Pwc600Connectivitypackage1 vulnerabilities
- Relion 6301 vulnerabilities
- Rtu500 Scripting Interface1 vulnerabilities
- Sam600Ioconnectivitypackage1 vulnerabilities
- Txpert Hub Coretec 51 vulnerabilities
CVE-2018-1168abbabb microscada+1
EPSS score0.31%
This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.CVE-2018-20720hitachienergyrelion_630_firmwareEPSS score2.47%
ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service (reboot) via a reboot command in an SPA message.CVE-2018-14805hitachienergyesoms+1EPSS score4.81%
ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Both conditions are required to exploit this vulnerability.CVE-2021-40333hitachi energyfox61x+3EPSS score0.66%
Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A.CVE-2021-40342hitachi energyfoxman-un+3EPSS score0.29%
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*CVE-2021-40336hitachi energymsm+1EPSS score0.50%
A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. This causes a possible HTTP response splitting, which if exploited could lead an attacker to channel down harmful code into the user’s web browser, such as to steal the session cookies. Thus, an attacker who successfully makes an MSM user who has already established a session to MSM web interface clicks a forged link to the MSM web interface, e.g., the link is sent per E-Mail, could trick the user into downloading malicious software onto his computer. This issue affects: Hitachi Energy MSM V2.2 and prior versions.CVE-2021-40334hitachi energyfox61x+3EPSS score0.99%
Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi Energy XCM20 versions prior to R15A.CVE-2021-40341hitachi energyfoxman-un+3EPSS score0.09%
DES cipher, which has inadequate encryption strength, is used Hitachi Energy FOXMAN-UN to encrypt user credentials used to access the Network Elements. Successful exploitation allows sensitive information to be decrypted easily. This issue affects
* FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*CVE-2021-40335hitachi energymsm+1EPSS score0.23%
A vulnerability exists in the HTTP web interface where the web interface does not sufficiently verify if a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. This cause a Cross Site Request Forgery (CSRF), which if exploited could lead an attacker to gain unauthorized access to the web application and perform an unwanted operation on it without the knowledge of the legitimate user. An attacker, who successfully makes an MSM user who has already established a session to MSM web interface clicks a forged link to the MSM web interface, e.g., link is sent per E-Mail, could perform harmful command on MSM through its web server interface. This issue affects: Hitachi Energy MSM V2.2 and prior versions.CVE-2021-26845hitachienergyesomsEPSS score0.93%
Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. This issue affects: Hitachi ABB Power Grids eSOMS 6.0 versions prior to 6.0.4.2.2; 6.1 versions prior to 6.1.4; 6.3 versions prior to 6.3.CVE-2021-27416hitachi abb power gridsellipse enterprise asset management (eam)+1EPSS score0.62%
An attacker could exploit this vulnerability in Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 by tricking a user to click on a link containing malicious code that would then be run by the web browser. This can result in the compromise of confidential information, or even the takeover of the user’s session.CVE-2021-27414hitachi abb power gridsellipse enterprise asset management (eam)+1EPSS score0.57%
An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials.CVE-2021-27196hitachienergyfox615_tego1_firmware+8EPSS score1.57%
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.CVE-2021-35534hitachi energygms600+10EPSS score1.79%
Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0; 1.3.0.1; 1.2.0. Hitachi Energy PWC600 1.0.1 version 1.0.1.4 and prior versions; 1.1.0 version 1.1.0.1 and prior versions.CVE-2021-35533hitachi energyrtu500 series+1EPSS score0.95%
Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions).CVE-2021-35532hitachi energytxpert hub coretec 4 version+1EPSS score0.17%
A vulnerability exists in the file upload validation part of Hitachi Energy TXpert Hub CoreTec 4 product. The vulnerability allows an attacker or malicious agent who manages to gain access to the system and obtain an account with sufficient privilege to upload a malicious firmware to the product. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0; 2.0.1; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1.CVE-2021-35531hitachi energytxpert hub coretec 4 version+1EPSS score0.26%
Improper Input Validation vulnerability in a particular configuration setting field of Hitachi Energy TXpert Hub CoreTec 4 product, allows an attacker with access to an authorized user with ADMIN or ENGINEER role rights to inject an OS command that is executed by the system. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0; 2.0.1; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1.CVE-2021-35530hitachi energytxpert hub coretec 4 version+1EPSS score0.22%
A vulnerability in the application authentication and authorization mechanism in Hitachi Energy's TXpert Hub CoreTec 4, that depends on a token validation of the session identifier, allows an unauthorized modified message to be executed in the server enabling an unauthorized actor to change an existing user password, and further gain authorized access into the system via login mechanism. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0 2.1.0; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1.CVE-2021-35529hitachi abb power gridscounterparty settlement and billing (csb)+3EPSS score1.26%
Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing (CSB) allows an attacker or unauthorized user to access database credentials, shut down the product and access or alter. This issue affects: Hitachi ABB Power Grids Retail Operations version 5.7.2 and prior versions. Hitachi ABB Power Grids Counterparty Settlement Billing (CSB) version 5.7.2 and prior versions.CVE-2021-35527hitachi abb power gridsesoms+1EPSS score1.02%
Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.