Hitachienergy vulnerabilities, page 2
103 vulnerabilities
Known vulnerabilities in Hitachienergy products, newest first, with CVSS severity, EPSS, KEV listings and ransomware use, across 46 products.
CVE-2021-35528hitachi energycounterparty settlement and billing (csb)+3
EPSS score0.26%
Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute a modified signed Java Applet JAR file. A successful exploitation may lead to data extraction or modification of data inside the application. This issue affects: Hitachi Energy Retail Operations 5.7.3 and prior versions. Hitachi Energy Counterparty Settlement and Billing (CSB) 5.7.3 prior versions.CVE-2021-35535hitachi energyrelion 670 series+5EPSS score0.67%
Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions.CVE-2025-39201hitachi energymicroscada x sys600+1EPSS score0.13%
A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.CVE-2025-39204hitachi energymicroscada x sys600+1EPSS score0.36%
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user.CVE-2025-39203hitachi energymicroscada x sys600+1EPSS score0.22%
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop.CVE-2025-39205hitachi energymicroscada x sys600+1EPSS score0.20%
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.CVE-2025-39202hitachi energymicroscada x sys600+1EPSS score0.23%
A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.CVE-2022-2513hitachi energy650 connectivity package+11EPSS score0.15%
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs.CVE-2022-2277hitachi energymicroscada x sys600+1EPSS score0.77%
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*CVE-2022-2502hitachi energyrtu500 series+1EPSS score0.65%
A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.CVE-2022-2081hitachi energyrtu500 series cmu firmware+4EPSS score0.64%
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.CVE-2022-2155hitachi energylumada apm+1EPSS score0.37%
A vulnerability exists in the affected versions of Lumada APM’s User Asset Group feature
due to a flaw in access control mechanism implementation on the “Limited Engineer” role, granting it access to the embedded Power BI reports
feature. An attacker that manages to exploit the vulnerability on a customer’s Lumada APM could access unauthorized information by gaining
unauthorized access to any Power BI reports installed by the customer.
Furthermore, the vulnerability enables an attacker to manipulate asset issue comments on assets, which should not be available to the attacker.
Affected versions
* Lumada APM on-premises version 6.0.0.0 - 6.4.0.*
List of CPEs:
* cpe:2.3:a:hitachienergy:lumada_apm:6.0.0.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:lumada_apm:6.1.0.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:lumada_apm:6.2.0.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:lumada_apm:6.3.0.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:lumada_apm:6.4.0.0:*:*:*:*:*:*:*CVE-2022-1778hitachi energymicroscada x sys600+1EPSS score0.48%
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*CVE-2022-4608hitachi energyrtu500 series+1EPSS score0.71%
A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.CVE-2022-29490hitachi energymicroscada x sys600+1EPSS score0.64%
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*CVE-2022-29492hitachi energymicroscada pro sys600+2EPSS score0.75%
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*CVE-2022-29922hitachi energymicroscada pro sys600+2EPSS score0.79%
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*CVE-2022-28613abbrtu500_firmware+2EPSS score0.99%
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.CVE-2022-3353hitachi energyfox61x tego1+25EPSS score1.10%
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.
An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.
Already existing/established client-server connections are not affected.
List of affected CPEs:
* cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*CVE-2022-3928hitachi energyfoxman-un+3EPSS score0.22%
Hardcoded credential is found in affected products' message queue. An attacker that manages to exploit this vulnerability will be able to access data to the internal message queue.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*