CVE-2018-4848: siemens scalance_x-200_firmware
Vulnerability summary
CVE-2018-4848 is a medium (CVSS 6.1) vulnerability in siemens scalance_x-200_firmware. EPSS estimates a 1.02% chance of exploitation in the next 30 days, higher than 62.9% of scored vulnerabilities.
Timeline
- 14-06-2018PublishedVulnerability first disclosed.
- 05-08-2024Last modifiedVulnerability information updated.
Description
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
CVSS metrics
2 scores · 1 source · 2 versionsEPSS trend
Probability
1.02%
Chance of exploitation in the next 30 days
Percentile
63%
Versus all other CVEs
30-day change
0.00 pp
From 1.02% on 19-09-2026
Known exploited
Compare KEV catalogsNot in any of the 3 tracked catalogs.
Public exploits
0 foundNo public exploits indexed.
Weaknesses
CWE · root cause- CWE-80Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)The product receives input from an upstream component, but it does not neutralize or incorrectly neutralizes special characters such as "<", ">", and "&" that could be interpreted as web-scripting elements when they are sent to a downstream component that processes web pages.
- CWE-79Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
Affected systems
Siemens6 products
- scalance_x-200_firmware< 5.2.3
- scalance_x-200_irt_firmware< 5.4.1
- scalance x-200 switch family (incl. siplus net variants)All versions < V5.2.3
- scalance x-200irt switch family (incl. siplus net variants)All versions < V5.4.1
- scalance x-200rna switch familyAll versions < V3.2.7
1 vendor · 6 products